READ AND UNDERSTAND ALL TRACK, CONNECTOR, FEED-IN-KITS, AND ACCESSORY
INSTRUCTION SHEETS BEFORE INSTALLING ANY TRACK ITEM
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal regulations. To assure full compliance with codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
LIGHTOLIER a GENLYTE company.
®
INSTRUCTION SHEET NO.
IS:26096
0597 Page 1 of 3
GRID CEILING CANOPY KIT AND GRID CEILING MOUNTING CLIPS
FOR USE WITH PROSPEC
®
TRACK SYSTEMS ONLY
A. INSTRUCTIONS
1. Remove appropriate VERTICAL K.O.’s for T-BAR from OUTLET BOX. DO NOT REMOVE ANY RECTANGULAR K.O.’s. (Fig. 1)
2. Attach a bare or green color insulated 12 AWG solid copper GROUND WIRE approximately 8” long to the OUTLET BOX using the GROUND CLIP (supplied). Position GROUND CLIP as shown in Fig. 2. Bend wire so unattached end is pointing away from the OUTLET BOX. (Fig. 3).
3. Remove K.O. from top of OUTLET BOX and fasten an electri­cal connector (by others).
4. Place OUTLET BOX on T-BAR(s). If OUTLET BOX does not fit over the BULB of the T-BAR(s), flatten the BULB with a pair of pliers.
5. Pass SUPPLY LEADS through electrical connector leaving approximately 8” of wire beyond the box. WIRES MUST BE DRESSED AS SHOWN. (Fig. 4)
6. Fasten 12 AWG solid SUPPLY GROUND WIRE to OUTLET BOX using a GROUND CLIP (supplied). Position 180° from other GROUND CLIP. (Fig. 2)
CAUTION:
• TURN OFF POWER AT FUSE BOX BEFORE INSTALLING TRACK.
• DO NOT MAKE ELECTRICAL SPLICES IN OUTLET BOX OF GRID CEILING CANOPY KIT.
• USE SOLID 12 AWG WIRES FOR SUPPLY TO TRACK (NOT STRANDED).
• INSTRUCTIONS FOR GROUNDING MUST BE FOLLOWED. FAILURE TO DO SO MAY RESULT IN AN ELECTRICAL HAZARD.
C
A B
CEILING & CEILING PANEL TYPE
GRID CEILING MOUNTING CLIP INSTRUCTIONS
15/16”
9/16
(ORDER SEPARATELY)
6089
CANOPY SPACER CROSS BAR & CANOPY
15/16”
9/16
5/16” to 13/32”
9/16”
1/8 - 1/4”
5/16”
(ORDER SEPARATELY)
6087
USE
USE
USE
USE
USE
USE
(SUPPLIED)
(ORDER SEPARATELY)
6088
FIG. 1
OUTLET
BOX
CROSSBAR
GROUND WIRE
CANOPY PLATE
T-BAR
RECTANGULAR KO
CANOPY SPACER
BOT TOM COVER
THIN HEAD SCREW
VERTICAL KO
FEED TRACK OR CONNECTOR
READ AND UNDERSTAND ALL TRACK, CONNECTOR, FEED-IN-KITS, AND ACCESSORY
INSTRUCTION SHEETS BEFORE INSTALLING ANY TRACK ITEM
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal regulations. To assure full compliance with codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
LIGHTOLIER a GENLYTE company.
®
INSTRUCTION SHEET NO.
IS:26096
0597 Page 2 of 3
7. Rotate GRID CEILING MOUNTING CLIPS onto the T-BAR. (Fig. 3) Use 2 GRID CEILING MOUNTING CLIPS for a 2’ or 4’ TRACK UNIT, 3 for an 8’ TRACK UNIT, and 4 for a 12’ TRACK UNIT. DO NOT EXCEED 4’ BETWEEN T-BAR MOUNTING CLIPS. Use more CLIPS for additional support in heavily loaded applications.
8. Remove BOTTOM COVER from FEED TRACK or CONNECTOR.
9. Remove the KNOCK OUT PLATEfrom the FEED TRACK or CONNECTOR (retain the SCREW). (Fig. 5)
10. Break the proper TAB from the PLATE ASSEMBLY:
FEED TRACK: DO NOT BREAK ANY TAB. (Fig. 5)
POWER EXTENSION, IN-LINE, “ T”, AND “X” CONNECTORS: BREAK THE 90° TAB OFF THE PLATE ASSEMBLY. (Fig. 6)
“L” CONNECTOR: BREAK THE 90°TAB AND STRAIGHT TAB FROM THE PLATE ASSEMBLY. (Fig. 7)
11. Attach the PLATE ASSEMBLY onto the FEED TRACK or CONNECTOR using the SCREW. (Fig. 5 & 6)
12. Place the CANOPY SPACER on the PLATE ASSEMBLY.
13. Align the PLATE ASSEMBLY with the OUTLET BOX passing the wires through the center hole in the PLATE ASSEMBLY.
14. Secure the TRACK to the surface by rotating the MOUNTING CLIPS into the TRACK.
15. Rotate the CROSS BAR until the SLOTS are in-line with the OUTLET BOX MOUNTING HOLES.
NOTE: THE CROSS BAR MUST COVER THE SLOT IN THE CANOPY PLATE AFTER THE CANOPY PLATE IS ASSEMBLED. PLEASE CHECK BEFORE SECURING THE PLATE ASSEMBLY TO THE OUTLET BOX.
Secure the PLATE ASSEMBLYto the OUTLET BOX using the THIN HEAD SCREWS.
16. Attach the GROUND WIRE on the CANOPY PLATEto the OUTLET BOX. Slide the CANOPY PLATE between the CROSS BAR and FEED TRACK or CONNECTOR.
17. Wire the TRACK or CONNECTOR as shown in instruction sheets IS:26000, IS:26046, or IS :26050 which are included in the TRACK and CONNECTOR packages.
18. Snap the BOTTOM COVER into the TRACK or CONNECTOR to cover the wire terminals.
FIG. 4
FIG. 3
BULB
T-BAR
OUTLET BOX
VERTICAL K . O.
RECTANGULAR K .O.
GRID CEILING MOUNTING CLIP
GROUND WIRE
GROUND CLIP
OUTLET BO X CLIP
FIG. 2
GROUND CLIP
90 °
FIG. 5
FEED TRACK
PLATE ASSEMBLY
SCREW
KNOCK OUT PLATE
FIG. 7
“L” CONNECTOR
STRAIGHT TAB
PLATE ASSEMBLY
90 ° TA B
KNOCK OUT PLATE
FIG. 6
POWER EXTENSION CONNECTOR, IN-LINE, “T”, OR “X”
PLATE ASSEMBLY
SCREW
90 ° TA B
KNOCK OUT PLATE