Lightolier 23C20BT User Manual

®
Track Lighting System  23C20BT
Page 1 of 2 Alcyon HID 20W CDM-Tm PGJ5
7 13/16 in [199 mm]
3 1/16 in [78 mm]
1 15/16 in
[50 mm]
8
1 1/16 in [27 mm]
2
7
6 5/8 in
[168 mm]
1 1/2 in
[38 mm]
10
6
7 in
[178 mm]
3 5/16 in
6 5/16 in
[160 mm]
9
1/4 in
[6 mm]
3 7/8 in
[98 mm]
[84 mm]
1
3
4
5
Orde ring Information
Catalog No.  Finish  Mounting  Lamps
23C20BTAL  Aluminum For use with Lytespan Radius, 20W CDM-Tm PGJ5 Base 23C20BTBK  Black Basic and Advent Track. Ceramic Metal Halide 23C20BT WH  White Not compatible with extension Philips
wands or slope ceiling adapters. For monopoint applications refer to spec sheet 6172.
Features
1.  Track At tachment Fitting: Locking lever for mechanical/
electrical connection.
2.  Brass Contact: Extends for connection to second circuit (Advent track only).
3.  Horizontal Pivot: Wireless stem profile with 365° horizontal rotation.
Position may be locked using an allen key.
4.  Vertical P ivot: 0-90° vertical adjustment with aiming indicator. Position may be locked using an allen key.
5.  Fixture Housing: Die cast aluminum
6.  Ballast Housing: Molded polycarbonate
7.  Safety Lens: Tempered 1/8" glass. Meets or exceeds UL safet y requirement
for metal halide lamps.
8.  On/Off Switch: Rocker switch to disconnect power to the ballast.
9.  Accessory Cartridge: Hinged and captive; retaining ring included. Inside
painted black to reduce glare.
10. Safety Locking Lever: Locks ballast housing to track.
Finish
All Painted finishes are baked enamel.
Accessories
Accessory Holder: Integral Accessories: Accepts 1 snoot plus 2 lenses or 1 louver plus 1 lens. When using 2 accesso ries, remove safet y lens provided. Lens: AF25, ADF25 Series Louver: AL25HC
Reflector
Interchangeable reflectors available to allow for desired beam spread. REFLECTORS SOLD SEPARATELY.
Electrical
Electronic Ballast Max. Input Current: 0.23A Input Voltage: 120V, 50/60Hz ANSI Code: M175 Power Factor: 0.9 Do not use on dimming circuit. Input Power: 26W
Labels
U.L. listed.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Reflectors (Sold Separately)
23MHRS  Clear Spot Reflector 23MHRNF  Clear Narrow Flood Reflector 23MHRF  Clear Flood Reflector 23MHRSCCZ  Champagne Bronze Spot Reflector 23MHRNFCC Z  Champagne Bronze Narrow Flood Reflector 23MHRFCCZ  Champagne Bronze Flood Reflector 23MHRSWRM  Incandescent Warming Spot Reflector 23MHRNFW RM  Incandescent Warming 23MHRF WRM  Incandescent Warming Flood Reflector
Narrow Flood Reflector
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2010 Philips Group • C0510
®
Track Lighting System  23C20BT
Page 2 of 2 Alcyon HID 20W CDM-Tm PGJ5
Aiming Angle:  0°  30° Horizontal  30° Vertic al  45° Vertical 
L Beam length D Distance W Beam Width A Aiming Angle C Distance to center beam FC Footcandles
L and W are the outer points where the candle
power drops to 50% of the maximum. FC are the initial footcandles at the center of the beam.
Lamp data shown is typical. Consult lamp manufacturers for availability and performance.
CBCP = Center Beam Candle Power.
Beam Spread
Lamp
(To 50% CBCP) Life (Hrs.)
12423 12000 22W BT-5, 23MHRS 10°
Rated
CBCP
  D  FC  L  W   D  C  FC  L  W   D  C  FC  L  W   D  C  FC  L  W
10' 124 1.7' 1.7' 12' 8 6 2.1' 2.1' 14' 63 2.4' 2.4' 16' 49 2.8' 2.8'
8' 4.6' 126 1.9' 1.6' 10' 5.8 ' 81 2.3' 2.0' 12' 6.9' 56 2.8' 2.4' 14' 8 .1' 41 3.3' 2.8'
3' 5.2 ' 173 2.1' 1.0' 4' 6.9 ' 97 2. 9' 1.4' 5' 8.7' 62 3. 6' 1.7' 6' 10.4' 43 4. 3' 2.1'
4' 4.0 ' 275 1.4' 1.0' 5' 5.0 ' 176 1.8' 1.2' 6' 6.0 ' 122 2.1' 1.5' 7' 7.0' 90 2.5' 1.7'
Beam Spread
Lamp
(To 50% CBCP) Life (Hrs.)
2538 12000 22W BT-5, 23MHRNFF 25°
Beam Spread
Lamp
(To 50% CBCP) Life (Hrs.)
1895 12000 22W BT-5, 23MHRF 35°
Rated
CBCP
Rated
CBCP
  D  FC  L  W
6' 71 2.7' 2.7' 8' 40 3. 5' 3.5' 10' 25 4.4' 4.4' 12' 51 5.3' 5.3'
  D  FC  L  W   D  C  FC  L  W   D  C  FC  L  W   D  C  FC  L  W
6' 53 3.8' 3.8' 8' 30 5.0' 5.0' 10' 19 6.3' 6.3' 12' 13 7.6' 7.6'
Note:  For Champagne Bronze (CCZ), multiply FC values by 0.64.
For Incandescent Warm (WRM), multiply FC values by 0.85.
  D  C  FC  L  W   D  C  FC  L  W   D  C  FC  L  W
6' 3.5' 46 3. 6' 3.1' 8' 4.6 ' 26 4. 8' 4.1' 10' 5.8' 16 6.0' 5.1' 12' 6.9' 11 7.2' 6.1'
6' 3.5' 34 5.2' 4.4' 8' 4.6' 19 7.0' 5.8' 10' 5.8' 12 8.7' 7.3' 12' 6.9' 8 10.4' 8.7'
2' 3.5' 79 4. 2' 1.8' 3' 5.2 ' 35 6. 2' 2.7' 4' 6.9 ' 20 8. 3' 3.5' 5' 8.7' 13 10.4' 4.4'
2' 3.5' 59 7.2' 2.5' 3' 5.2 ' 26 10.8 ' 3.8' 4' 6.9 ' 15 14.4' 5.0' 5' 8.7' 9 18.0 ' 6.3'
2' 2.0 ' 224 1.9' 1.3' 3' 3.0 ' 100 2.8' 1.9' 4' 4.0 ' 56 3.7 ' 2.5' 5' 5.0 ' 36 4.7 ' 3.1'
2' 2.0 ' 167 2.8' 1.8' 3' 3.0 ' 74 4.2' 2.7' 4' 4.0 ' 42 5. 6' 3.6' 5' 5.0 ' 27 7.0' 4.5'
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2010 Philips Group • C0510
Job Information Type:
Loading...