Lightolier 1101 User Manual

This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electric shock, turn off electricity at main power supply before proceeding.
INSTALLATION PROCEDURE FOR: Lytecaster® 1101, 1001 and 2001 Series Trims
1101 Series Trims for use with 1101 Series Frame-In Kits only. 1001 Series Trims for use with 1001 Series Frame-In Kits only.
CAUTION: (RISK OF FIRE) FOR NON-IC RATED INSTALLATIONS, DO NOT INSTALL INSULATION ABOVE
CAUTION: USE ONLY WITH FRAME-IN KITS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURER’S FRAME-IN
CAUTION: BEFORE INSTALLING REFLECTOR TO FRAME-IN KIT, READ ALL MARKINGS ON REFLECTOR AND ON FRAME-
1
2 POSITION TRIM CLIPS (Figure A):
4 PUSH UP (Figure C):
KITS MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
FRAME-IN KIT INSTALLATION: See Frame-In Kit Instruction Sheet for installation procedure.
Trim Clips (Quantity (4) on 1101 and 1001 series Frame-In Kits, Quantity (3) on 2001 series Frame-In Kits) must be positioned to extend inward towards center of aperture as shown in Figure A. Rotate into position if necessary.
Insert Socket Cup into neck of reflector. Make sure springs of socket cup snap into reflector slots.
NOTE: For optimum fixture performance, Lightolier recommends the Frame-In Kit, Lamp Type and Lamp Position combinations shown in the chart to the right. (Vertical trims only.)
Push Reflector Trim straight up until it is tight against the ceiling.
NOTE: To remove Reflector Trim, turn Reflector Trim counter-clockwise while pulling downward.
READ AND UNDERSTAND THESE INSTRUCTIONS
BEFORE INSTALLING LUMINAIRE.
INSTRUCTION SHEET NO.
IS:1101
Retain these instructions for maintenance reference.
2001 Series Trims for use with 2001 Series Frame-In Kits only.
OR WITHIN 3 INCHES (76mm) OF ANY PART OF LUMINAIRE.
IN KIT TO DETERMINE LAMP WATTAGE AND TYPE APPLICABLE FOR YOUR INSTALLATION.
Frame-In Kit Upper Trim Slot Lower Trim Slot
2001 Series
1001 Series
1101 Series
A1106
18w Triple Tube 13w Quad Tube 26w Triple Tube 18w Triple Tube 13w Quad Tube 13w Triple Tube 42w Triple Tube 32w Triple Tube 26w Quad Tube 26w Triple Tube 18w Quad Tube 18w Triple Tube
Page 1 of 1
13w Triple Tube
Figure A
For Wall Wash Series Trims: Position the trim so that wall wash reflector opening is pointed towards the wall to be
*
illuminated before completing step 4 (Figure D). This direction is indicated by a label on the Frame-In Kit.
For Cross Blade Series Trims: Install Trim as instructed above in steps 1-4. For re-lamping or to align the cross
*
blade assembly to the ceiling, remove the cross blade cone assembly from the trim by pulling the cone portion of the assembly straight down (it may be necessary to repeat this at multiple positions to work the cross blade assembly out of the reflector). To replace, align blades and push the cross blade cone assembly straight up into main trim reflector until each of the 3 cone retention clips are fully engaged in the groove on the exterior of the cone.
For Lens Series Trims: Install Trim as instructed above in steps 1-4. For re-lamping, remove just the lens support
*
cone from the trim by inserting a finger between the lens and the support cone, gripping the cone and pulling straight down (it may be necessary to repeat this at multiple positions to work the cone out of the reflector). The lens will hang from the reflector by a chain located behind the cone. To replace the lens and cone, place the lens on top of the support cone and push straight up into main trim reflector. Make sure the lens chain is hidden behind the cone and does not interfere with the full engagement of the 3 cone retention clips into the groove on the exterior of the cone.
Figure B
Figure C
A COMPANY
Figure D
631 Airport Road, Fall River, MA 02720