Lytecaster
®
Recessed Downlighting 1035
Page 1 of 2 5" Aperture Step Baffle Wall Washer Reflector Trim
6 3/4"
5/8"
1035/1002P1 Series
Standard Incandescent
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
6 3/4"
7 1/4"
Reflector Trim Frame-In Kit — See Individual Frame-In Kit Specification Sheets
Incandescent Fluorescent
1035
White plate with
matte black step baffle
1035WH
White plate with
matte white step baffle
Frame-In Kit Ceiling Type Lamping Height Frame-In Kit Ceiling Type Lamping Height
1002P1
1000P1
1003R
1000IC
1000AICM
1004ICX/N
Non-IC
Non-IC
Non-IC Remodeler 60W A19
IC
AirSeal® IC
AirSeal® IC
60W A19
75W BR30
85W BR30
40W A19
6 3/4"
6 3/4"
6 3/4"
7 5/16"
7 5/16"
7 1/4"
1001F13U Series
1001F18U Series
1004F13 Series
1004F18 Series
1004F26 Series
1001F13ICU/N
UniFrame™
Non-IC
UniFrame™
Non-IC
IC (1) Quad/Triple 13W (GX24q-1) 7 1/2"
IC (1) Triple 18W (GX24q-2) 7 1/2"
IC (1) Triple 26W (GX24q-3) 7 1/2"
Performance IC(1) Triple 13W (GX24q-1) 7 1/4"
1035/1003R
0
Non-IC Remodeler
1035/1004ICX/N
0
AirSeal® Insulated Ceiling
(1) Triple 13W (GX24q-1) 5 7/8"
(1) Triple 18W (GX24q-2) 5 7/8"
™
™
Features
1. Reflector: Hydroformed aluminum, .040" thick, (18 ga.); Anobrite
(anodic-processed) semi-specular finish for permanent reflectivity; matte
white trim flange.
2. Step Baffle:
low brightness, matte black or matte white finish.
3. Aperture Plate:
spin locked to step baffle; snaps out with step baffle and scoop reflector by
means of concealed retaining springs for relamping.
4. Scoop Reflector:
(anodic processed) semi-specular finish for permanent high reflectivity;
provides an even wash of light over wall surfaces without scallops or
shadows.
5. Frame-In Kit:
and shown.
Die cast aluminum with stepped conical surface for
Semi-circular; die formed steel; matte white or gloss white;
Hydroformed aluminum, .040" thick (18 ga.); Anobrite®
(1002P1 standard frame shown). Other frames listed above
®
Options & Accessories
Retaining Clips: 1955 - For Installing in Existing Ceiling
Extra Wide Flange Trim Ring: 1957 - 7" O.D.
1001F18ICU/N
1910XFH1
Performance IC(1) Triple 18W (GX24q-2) 7 1/4"
Conversion
Kit
(1) Quad 13W (GX23-2) 6 3/4"
Labels
UL (Suitable for Damp Locations), I.B.E.W.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • K1007
Lytecaster
®
Recessed Downlighting 1035
Page 2 of 2 5" Aperture Step Baffle Wall Washer Reflector Trim
LIGHTING DATA
EXAMPLE: Multiple units with 75W BR30 FL lamps, located
2’ from wall and 2’ on center, provide illumination on the wall
3’ down from the ceiling of 18 f.c. beneath and 17 f.c. between
the fixtures.
FOOTCANDLES ON WALL FROM MULTIPLE UNITS
60W A19
UNITS 2 FEET FROM WALL
2’ 3’
1 17 16 17 12 9 12
2 18 18 18 13 11 13
3 13 13 13 9 8 9
4 9 9 9 6 6 6
5 6 6 6 4 4 4
6 4 4 4 3 3 3
7 3 3 3 2 2 2
DISTANCE FROM CEILING, FT.
8 2 2 2 1 1 1
9 2 2 2 1 1 1
1 8 8 8 7 4 7
2 11 11 11 8 7 8
3 9 9 9 6 6 6
4 6 6 6 4 4 4
5 4 4 4 3 3 3
6 3 3 3 2 2 2
7 2 2 2 1 1 1
DISTANCE FROM CEILING, FT.
8 1 1 1 1 1 1
9 1 1 1 1 1 1
13W Quad Tube
UNITS 2 FEET FROM WALL
2’
3’
75W BR30 FL
UNITS 2 FEET FROM WALL
2’ 3’
1 24 23 24 16 16 16
2 20 20 20 16 12 16
3 18 17 18 12 12 12
4 13 13 13 9 9 9
5 9 9 9 7 6 7
6 7 7 7 5 5 5
7 5 5 5 4 4 4
DISTANCE FROM CEILING, FT.
8 4 4 4 3 3 3
9 3 3 3 3 3 3
Footcandle values are averaged and rounde d of f an d ar e ba sed on a minimum of five units.
For fixture-to-wall distances, other than tho se s hown , us e maximum of 1 of 1 spacing (distance between fixtures not more than distance to wall) for best result.
To convert lighting data for a lower wattage incande scen t la mp o f th e same type, multiply the footcandle values by the ratio of the lumens of the two lamps.
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • K1007