![](/html/8d/8d9a/8d9a94f4c61ef3ce86ab16d5efa95622cfb17b1968cc410c2f31ebe0b6940ca7/bg2.png)
MANUAL
ARCTIC STANDARD
ENG
Name
ARCTIC STANDARD 1200 TH
4000K /E/
ARCTIC STANDARD 1500 TH
4000K /E/
Notes:
Rated CCT tolerance ±300
Luminaire is manufactured for climatic conditions according to IEC 60721-2-1, lowest operating temperature - 40ºC.
Luminaire corresponds to the protection classification IP65 by EN 60529
Luminaire corresponds to the impact protection IK02 by EN 62262
Power, W
Luminous
flux, lm,
±5%
33 3300 100 4000 1280 x 96 x 110 932
45 4500 100 4000 1582 x 96 x 110 1230
±10%
Luminous
efficiency lm/W
CCT, K
Size, mm,
(Length x Width x
Height
A x B x C)
Mounting
dimension (D),
mm
DELIVERY SET
Luminaire, pcs. 1
Package, pcs. 1
Manual, pcs. 1
Cable gland, pcs. 2
M6 washer, pcs. 2
Rubber washer, pcs. 2
ARCTIC (2) wire pendant mounting kit (to be ordered
separately), pcs 1
FUNCTION
This LED luminaire is designed for illumination of premises with increased humidity.
Replacement of the luminaire light source is available in the factory or by a specialized service.
The luminaire corresponds to the safety requirements IEC 60598-2-1, EN 55015.
The luminaire is intended for operation in AC/DC mains 230-240 V (±10%), 0/50-60 Hz (±0,4 Hz). The
supply mains have to be protected from communication and electric impulse noise.
SAFETY NOTICE
These instructions assume expert knowledge corresponding to a completed professional education
as an electrician.
![](/html/8d/8d9a/8d9a94f4c61ef3ce86ab16d5efa95622cfb17b1968cc410c2f31ebe0b6940ca7/bg3.png)
Never work on the luminaire when the voltage is switched on.
Do not operate the luminaire without protective grounding.
Position the luminaire to avoid long viewing into the luminaire at a distance of less
than 0.5 m.
Only operate the luminaire if the diffuser is undamaged.
Do not disassemble, repair, or modify the luminaire. Caution - danger of
electric shock!
The light source contained in this luminaire shall only be replaced by the manufacturer or his service
agent or a similar qualified person.
In case of a malfunction, immediately unplug the luminaire from the mains supply.
Only perform installation and maintenance with the luminaire disconnected from the
mains supply.
The luminaire has passed the high-potential dielectric strength test as per IEC 60598-1-2014.
Do not cover the luminaire with insulating material
INSTALLATION AND OPERATION RULES
The luminaire should be used according to «Standard code of customer electrical installations».
Installation, cleaning and replacing of the components should be done only with the main power off. The
diffuser should be cleaned with soft cloth and mild detergent.
1. Switch mains power off. Strip mains cable (max 2.5 mm2) according to figure. Unpack the
luminaire.
2. Remove diffuser from unpacked luminaire, remove assembly panel.
ATTENTION!!!
Touching LED board surface with hands or solid objects is not allowed in order to avoid LED damage.
When powered on, there is hazardous voltage on LED board. Do not turn on without diffuser!
![](/html/8d/8d9a/8d9a94f4c61ef3ce86ab16d5efa95622cfb17b1968cc410c2f31ebe0b6940ca7/bg4.png)
3. Bearing surface installation. Drill the mounting holes in the ceiling and luminaire’s body, L –
distance between holes: (on fig. а – rubber washer; b - М6 steel washer).
3.1 Suspended installation. Drill installation holes in luminaire's body, L – distance between holes:
(on fig. а – М6 steel washer; b - rubber washer; с- М6 nut).
4. Put mains cable through cable gland, which should have previously made opening with form
of mains cable profile and a bit less in size. Place the cable glands in appropriate holes in
luminaire’s body.