Lift-Master 24VDC User Manual

INSTALLATION INSTRUCTIONS
1. Remove Blue Jumper from J12 to J18.
MODIFICATION FOR
24VDC ADA LIGHT
MODEL: FDCL
2. Add Blue Jumper from J12 to Pin 20 on Connector.
3. Add Blue Jumper from J18 to Pin 20 on Connector.
4. Add Red Jumper from Pin 19 on Connector to Terminal 2.
5. Add Black Jumper from Pin 15 on Connector to Terminal 1.
6. Mount Horn on Wall, Wire Accordingly.
J14
J15
J13
WARNING
TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER TO OPERATOR BEFORE INSTALLING.
J30 J18 J17 J16
J19 J5
10
9
8
7
6
5
4
3
2
1
(RD)
(BK)
J12
J9
J8
(BL)
181716151413
123456 7 8 9 10 11 12
24VDC TO DRIVE ADA LIGHT/ HORN UNDER ALARM CONDITION CONNECT AT TERMINAL 1 AND 2.
01-17980A All Rights Reserved