![](/html/bc/bc49/bc497b9260d1e390c7781fb97d183e3e15edd1bb5999d8aa06a9e216d80fd2c9/bg1.png)
Installation instructions
Step 5 Push-fit fittings only
Thank you for purchasing your Liff Limebeater.
Following the installation instructions below will
ensure this product performs as specified.
There are eight Limebeater models: LBC2-15V2,
LBC2-22V2, LBC28, LBC35, LBC42, LBC54 and LBP2-15,
LBP2-22. The Numerals after the LBC and LBP indicate the
size of pipe fitting connections supplied.
Step 1
Turn off the water feeding the section of the pipe where you
wish to install the Limebeater.
Step 2
Drain the pipe-work if required.
Step 3
Select a suitable section of straight pipe and using the
Limebeater body as a measure cut out a piece of pipe.
Cut the pipe square, ensuring it is free of score marks,
burrs and sharp edges. Support Limebeater either side of
installation with appropriate brackets.
1. Gently push both ends of the existing pipework into the
Limebeater body until it touches the internal stops. The
collet has stainless steel teeth which grip the pipe whilst
the ‘0’ ring provides a leak-proof seal.
2. At this point the connection is gripped but not sealed. Pull
the pipe to check it is secure, which also makes the seal.
Note:
Do not insert fingers into fitting as the stainless steel teeth
incorporated within the collet may cause injury.
Step 6 Disconnecting a fitting
1. Ensure system is depressurised before removing fitting.
2. Push in collet squarely against face of fitting. With
the collet held in this position, the pipe can be easily
removed. The fitting can then be re-used.
Step 7
Installing isolating valves either side of the Limebeater
will facilitate the easy removal and replacement of the
Limebeater should the need arise. Please remember that the
pipe work either side of the Limebeater must be supported
by bracketing.
Step 4 Compression fittings only
1. With the section of pipe removed, unscrew the nuts and
remove the olives from either end of the Limebeater and
slide them onto either end of the remaining pipework.
2. Ease pipe apart and insert Limebeater between cut
sections of pipe.
3. Push each end of the existing pipework into the
Limebeater body until it is touching the internal stop.
4. Tighten up the nuts to make a water tight seal on
the olives.
Step 8
Turn the water back on and check for leaks.
NB. When fitting a Limebeater product, please ensure that
your installation complies with local plumbing codes and
practices.
Do not use a wrench or stilsons on the Limebeater
body as this will damage the casing.
![](/html/bc/bc49/bc497b9260d1e390c7781fb97d183e3e15edd1bb5999d8aa06a9e216d80fd2c9/bg2.png)
Installation
Instructions
Limebeater
Specifi cations
Model No.
Compression
LBC2-15V2
LBC2-22V2
LBC28
LBC35
LBC42
LBC54
Push - Fit
LBP2-15
LBP2-22
• Do not attach directly to any appliance. The Limebeater is best installed
approximately 1 metre from point of use.
• Flow through the Limebeater may be in either direction and it can be
installed horizontally or vertically.
• The pipe work either side of Limebeater must be supported by bracketing.
• Be sure to follow applicable Water Fitting Regulations when installing.
• Please ensure all hot pipe work is completed prior to installation.
Heat transfer may damage the product.
0.6
0.6
1.08
1.08
1.6
2.8
0.6
0.6
15mm
22mm
28mm
35mm
42mm
54mm
15mm
22mm
Dimensions
(L x W)
150mm x 35mm
154mm x 35mm
270mm x 41mm
270mm x 41mm
327mm x 67mm
450mm x 67mm
160mm x 35mm
167mm x 35mm
Electrolyic In-line Scale Inhibitor
Max Pressure
(Bar)
10
10
10
10
10
10
8
8
Guarantee
This product is guaranteed for the period of fi ve years from the date of purchase against
manufacturing faults. The guarantee is only valid if the product has been installed and used
in accordance with the manufacturers instructions and has not been dismantled or interfered
with in any way. Damage caused to the product or by the product as a result of failure to
use the product in accordance with the manufacturers instructions is not covered by this
guarantee. Under this guarantee we undertake at our discretion to repair or replace free of
charge the product or any part thereof that is found to be faulty.
Costs associated with the fi tting of a replacement product or part or the removal of
the product are not covered by this guarantee. Loss or damage caused by the product
(including consequential loss) is not covered by this guarantee. Proof of purchase must be
provided. This guarantee does not affect your statutory rights.
Max Water
Temperature (°C)
70
70
70
70
70
70
70
70
Body MaterialConnectionsFlow (L/S)
Copper
Copper
Copper
Copper
Copper
Copper
Copper
Copper
Limebeater
BWT UK Ltd. take great care to ensure that this document is correctly and
fairly stated at the time of publication. We reserve the right to update our
literature at any time without notice.
10/2016
All trademarks are protected under European law and must not be reproduced by third
parties without express permission of BWT UK Limited in writing.
As part of BWT’s policy of constant product development, BWT reserves the right to alter
product specifi cations without prior notice. © Copyright, BWT 2016.
If you have a technical query about your Liff product, or require information
on any of our other products please telephone us during normal office hours
on 01494 838100 or Email us at enquiries@bwt-uk.co.uk.
Alternatively visit our website
www.bwt-uk.co.uk at anytime.