DEAR CUSTOMER,
Thank you for choosing a LifeTool product and for choosing to use the IntegraMouse Plus as a valuable input device for your computer. These instructions for use contain useful and important information. Please read this manual carefully before using IntegraMouse Plus for the first time. LifeTool and your authorized IntegraMouse dealer will be happy to answer your questions. We wish you every success with your IntegraMouse Plus.
Responsible party: DynaVox Mayer-Johnson Address: 2100 Wharton Street, Suite 40 0, Pittsburgh, PA 15203 Telephone: 412 381-4883 INTERNET:
FCC Compliance Information Statement
www.dynavoxtech.com
Type of equipment: Computer mouse Model name: Integr aM ouse Pl us, IM+Connect
FCC Warning Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiv er .
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution
Note: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Label Warning
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
3
Contents
1. Contact .............................................................................................................................. 4
2. Notes on the instructions for use ....................................................................................... 4
3. Product information and use as per regulations ................................................................ 5
4. Safety instructions ............................................................................................................. 6
5. Scope of supply ................................................................................................................. 8
6. Product Description ........................................................................................................... 9
6.1 Components and operating elements ......................................................................... 9
6.2 Accessories and spare parts .................................................................................... 11
7. Commissioning ................................................................................................................ 13
7.1 Short introduction to initial operation ......................................................................... 13
7.2 General Installation notes ......................................................................................... 13
7.3 Switching on and activating ...................................................................................... 15
7.4 Calibration ................................................................................................................ 16
7.5 Using the IntegraMouse Plus silicon tube ................................................................. 17
8. Application and functionali ty ............................................................................................ 18
8.1 Switching on the IntegraM ous e Pl us ......................................................................... 18
8.2 Three operating modes: Mouse – Joystick – Cursor ................................................. 18
8.3 IntegraMouse Plus energy saving mode ................................................................... 22
8.4 Switching off the Integr aM ouse Pl us ......................................................................... 22
8.5 Wake on USB ........................................................................................................... 22
9. Hygiene, maintenance and testing .................................................................................. 23
9.1 Cleaning the mouthpiece and changing the membrane ............................................ 23
9.2 Cleaning the device .................................................................................................. 26
9.3 Recharging the battery ............................................................................................. 27
9.4 Metrological testing ................................................................................................... 27
10. Permissible system ...................................................................................................... 28
11. Ambient conditions ....................................................................................................... 29
12. Waste disposal ............................................................................................................. 30
13. Frequently asked questions and answers .................................................................... 30
14. Key to the symbols ....................................................................................................... 32
15. Product and performance data ..................................................................................... 33
16. Electromagnetic compatibility ....................................................................................... 35
4
1. CONTACT
MANUFACTURER'S ADDRESS:
LifeTool Solutions GmbH Hafenstraße 47-51 A-4020 Linz AUSTRIA INTERNET: www.integramouse.com
2. NOTES ON THE INSTRUCTIONS FOR USE
Please read these instructions for use completely before first use and keep them for reference for later use.
The triangle symbol indicates warnings, i.e. when failure to follow the
instructions may result in hazardous situations.
The information symbol indicates general notes and information.
The symbol with the snake on a green star indicates subject-specific
information, e.g. for medical personnel or hospital visitors.
Instructions for use are valid for the "IntegraMouse Plus" device version and its specific accessories.
Issue date: 01/03/2012. Technical changes reserved.
5
3. PRODUCT INFORMATION AND USE AS PER REG ULATIONS
IntegraMouse Plus is an electronic co mput er dev i c e made using the latest technology. It complies with part 15 of the FCC Rules. Details of this can be found in Chapter 17 "Declaration of Conformity".
IntegraMouse Plus is a fully adequate computer mouse that is operated with the mouth. For the operation of computer games, a joystick mode and a cursor mode are prov i ded. This allows persons who are no longer able to operate a traditional mouse to use a computer.
Possible users are persons with high-level paraplegia, with arms amputated on both sides or advanced diseases such as muscular dystrophy, amyotrophic lateral sclerosis or multiple sclerosis.
IntegraMouse Plus is connected to the computer by a USB cable and is Plug-and-Play capable, i.e. it is recognized and installed completely automatically as a Human Interface Device (HID). Power is also supplied via the USB cable. Alternatively the IntegraMouse Plus can communicate with the computer via a wireless radio link connection in the 2.4 GHz ISM Band. With this option, the power is supplied from the inbuilt battery or the power pack included.
IntegraMouse Plus is mainly designed to be used in dry rooms, in stationary settings on a PC or laptop. These include living rooms, clinics, rehabilitation centres, institutes, schools, universities and similar. However, usage in dry outside areas i.e. on patios, is also possibl e . The ambient temperatures during application must be between 50°F and 104°F. Avoid direct sunlight.
The placing and positioning of the IntegraMouse Plus must not be changed during use (tilt etc.) Also, the IntegraMouse Plus must not be influenced by external forces (for example, accelerations).
The mouthpiece can be changed. Cleaning is possible according to Chapter 9 "Hygiene, maintenance and testing". In clinical areas, the one-time use of the mouthpiece is strongly recommended. Through this, hygiene and cleanliness are guaranteed, also during use by several users (for example in public institutions) or during use in clinics and rehabilitations centres, where the risk of an infection by more resistant germs is present.
6
4. SAFETY INSTRUCTIONS
As with every product, there are a few things that must be noted in order to
ensure the safe and smooth operation of the IntegraMouse Plus:
Use this product only for the intended purpose according to these instructions for use. Any other use is improper and therefore dangerous. The manufacturer cannot be held responsible for damages which are caused by inappropriate or improper use.
Good head control and mouth motor skills are required for the operation of the IntegraMouse Plus. Therefore the IntegraMouse Plus must not be used by persons who suffer from e.g. uncontrolled spasms, Tourette's syndrome or epilepsy.
Only connect the device to sources of power as described in the instructions for use. Otherwise dangers may occur.
Do not expose the device to extreme tempera tur es and avoid direct sunlight. This can cause damage, especiall y to the built-in battery. Do not expose the device to any shaking (knocking, dropping) and protect it from dirt and damp. However, should the device be exposed to these conditions, allow your contract partner to examine it in order to ensure that it is safe and usable.
If you do not use the device for extended periods of time, switch the device off and store it according to Chapter 11 "Ambient conditions".
Use within strong electromagnetic fields can cause the device to malfunction.
The device must not be opened by the user as this would invalidate the manufacturer ' s
guarantee. Repairs may only be carried out by the manufacturer or its authorized partners. Incorrect handling of the internal battery can especially lead to hazards.
Persons who produce a large amount of saliva must not use the IntegraMouse Plus.
The IntegraMouse Plus may be used in combination with the attached IntegraMouse
Plus silicon tube, only by such persons that are not in danger of swallowing such objects.
The IntegraMouse Plus must not be used on moving systems (e.g. wheelchairs) or on systems with changes of position (e.g. changes of inclination).
The IntegraMouse Plus must not be used for the operation of life-supporting or safety devices such as emergency call installations, medication-dosing appar atus, m edic al expert systems, etc.
Children under 3 years of age are not permitted to operate the IntegraMouse Plus.
The IntegraMouse Plus must not be used in connection with HF surgical units or
defibrillators.
A combination with other devices than those described in Chapter 10 "Permissible system" is not permissible. Any other combination with medical products or other
7
products leads to the system integrator becoming the system manufacturer and also taking on responsibility for the product.
During highly infectious diseases, the mouthpiece must only be used once. The interval between changes of the mouthpiece must be determined by a doctor or an expert advisor.
Take regular breaks when you are working with computers. Physical signs of tiredness include eye pain, neck stiffness and other accompanying signs. A ten-minute break per hour of work is recommended.
IntegraMouse Plus may only be operated with a properly applied and seal-tested membrane.
Do not immerse the IntegraMouse Plus in water. The mouthpiece may be immersed but it has to be dismounted before cleaning. If you spill liquid over one or both parts, dry it immediately with a soft, lint-free cloth.
Do not clean the IntegraMouse Plus with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuits.
Do not subject the IntegraMouse Plus to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span and distorted parts.
Do not tamper with the IntegraMouse Plus internal components. Doing so will invalidate the warranty on the IntegraMouse Plus and may cause unnecessary damage. The IntegraMouse Plus contains no user-serviceable parts, apart the mouthpiece and the membrane.
If MagicArm® or an alternative stand, recommended by an IntegraMouse Plus dealer, is not used with the IntegraMouse Plus, no liability or responsibility for damage to equipment or persons is accepted.
Always read the user´s instructions thoroughly before operating the unit.
The manufacturer assumes responsibility for safety, reliability and performance of IntegraMouse Plus only if:
installation and operation conform to the instructions set out in this manual,
no alterations, changes or repairs are made (except by the manufacturer),
the instructions concerning the cleaning of the mouthpiece set out in this manual are
observed,
the membrane is replaced at the recommended intervals,
the device is used with original accessories only,
the device is not used when one or more parts are damaged,
the device is mounted to a stand recommended by an authorized IntegraMouse Plus
dealer
8
5. SCOPE OF SUPPLY
After opening the packaging, please check the delivery for completeness and check whether the IntegraMouse Plus or the accessories show any sign of damage or defects. If this is the case, contact your dealer immediately.
Figure 1: Scope of supply
No.
LifeTool
article number Quantity Description
1
11209
1
LifeTool: IntegraMouse Plus
2
11210
1
LifeTool: IntegraMouse Plus Connect (IM+Connect)
3
11211
2
LifeTool: IntegraMouse Plus mouthpiece
4
11212
1
LifeTool: IntegraMouse Plus USB cable
5
11213
12
LifeTool: IntegraMouse Plus membrane
6
11214
1
LifeTool: IntegraMouse Plus power pack
7
11218
1
LifeTool: IntegraMouse Plus silicon tube
8
11225
1
Handbook/manual
1
2
3
4
5 6 7
8
9
6. PRODUCT DESCRIPTION
6.1 Components and operating elements
1. IntegraMouse Plus
2. Mouthpiece with membrane
3. Silicon tube
4. IM+Connect
1
2
3
4
Figure 2: Components of the IntegraMouse Plus
10
Figure 3: Operating elements on the IntegraMouse (left) and IM+Connect (right)
1. ON/OFF key and calibration
2. Battery power display
3. Joystick mode display (J): Analogue joystick with key 1 and key 2
4. Cursor mode display (C): Cursor keys, space key and enter key
5. "Connect" key
6. Connectd LED
7. USB port
8. Jack socket: enables connection of an external sensor (3.5 mm mono jack) for the manual change between the three op er ati ng mod es mous e - joystick - cursor
Figure 4: Reverse side of the IntegraMouse Plus
All operating elements are latex free and free from poisonous components.
1
2
4
3
8 7 6
5
11
6.2 Accessories and spare parts
An overview of the technical data can be found in Chapter 15 "Product and
performance data".
The IM+Connect is plugged into the USB port of the computer and serves as a radio receiver in wireless mode.
IntegraMouse Plus Connect (IM+Connect)
The mouthpiece is in direct contact with the user's lips and is therefore the applied part. The mouthpiece is removable; therefore it can be replaced or cleaned separately.
IntegraMouse Plus mouthpiece
The power pack is used for charging the battery and also for supplying the IntegraMouse Plus with power in wireless mode. For safe operation, only use this power pack!
IntegraMouse Plus power pack
The USB cable is used to connect the IntegraMouse Plus with the computer in cable­connected mode. The internal battery of the IntegraMouse Plus is also charged at the same time. For safe operation, only use this USB cable!
IntegraMouse Plus USB cable
The membrane is necessary for the sipping/puffing function of the IntegraMouse Plus and also functions as a mechanical protective barrier to the electronics. The membrane should regularly be checked for damage and replaced.
IntegraMouse Plus membrane
If you prefer a soft surface on the mouthpiece, the silicon tube can be placed over the mouthpiece. This can make it more comfortable to use. Pay attention to the instructions for safe use of the silicon tube in Chapter
IntegraMouse Plus silicon tube
7.5. "Using the IntegraMouse Plus silicon tube".
Loading...