LIFETONE HLAC100 User Manual

LIFETONE HL
Bedside Fire Alarm & Clock
TM
User’s Manual
MODEL HLAC100
ENGLISH
SPANISH
LIFETONE HL
TM
Bedside Fire Alarm & Clock
User’s Manual
WARNING! DO NOT COVER
AC POWER
MODEL HLAC100
PLEASE READ THIS USER’S MANUAL COMPLETELY
AND THOROUGHLY BEFORE BEGINNING!
I. INTRODUCTION II. THE LIFETONE HL™ BEDSIDE FIRE ALARM AND CLOCK
A. CONTROLS AND DISPLAY B. FEATURES
III. WARNINGS IV. INSTRUCTIONS V. BEFORE INSTALLING VI. INST ALLA TION AND ACTIV A TION
A. LOCATION OF THE LIFETONE HL™ B. POWERING THE PRODUCT C. SELF-TEST D. SMOKE ALARM COMPATIBILITY TEST E. SETTING THE CLOCK F. SETTING THE ALARM G. TROUBLESHOOTING ERROR MESSAGES H. TESTING THE LIFET ONE HL™ I. UNSUCCESSFUL SMOKE ALARM COMPATIBILITY TEST VII. USING THE LIFETONE HL™ A. RECOGNIZING THE EMERGENCY ALARM SIGNALS B. CLOCK LIGHT PANEL C. BED SHAKER AND CARE VIII. REGULAR MAINTENANCE A. BATTERIES B. POWER ADAPTER
IX. FREQUENTLY ASKED QUESTIONS X. LIMITED WARRANTY XI.
RECOMMENDED LOCATIONS FOR SMOKE ALARMS
2 3
3 3-4 4-5 5-6
7
7
7
7 7-8 8-9
9
10 10 11 11 12 12 12 12 13 13 13 13 14 15
-1-
I. INTRODUCTION
Thank you for purchasing the Lifetone HL™ Bedside Fire Alarm and Clock. It is an important part of your family’s safety plan. The Lifetone HL™ is not a smoke detector and does not detect smoke. Instead, it detects the alarm sounds given by smoke alarms and smoke alarm systems that are UL- listed, or Intertek listed to the UL-217 standard, that emit a standardized T3 alarm signal. YOU MUST HAVE PROPERLY
INSTALLED UL- LISTED T3 SMOKE ALARMS IN YOUR HOME BEFORE THE LIFETONE HL™ BEDSIDE FIRE ALARM AND CLOCK WILL OPERATE CORRECTLY. THE LIFETONE HL™ BEDSIDE FIRE ALARM AND CLOCK IS NOT COMPATIBLE AND WILL NOT WORK IF YOU HAVE INSTALLED FIRST ALERT
®
ONELINK® TALKING WIRELESS ALARMS. THE LIFETONE HL™ IS COMPATIBLE WITH ALL OTHER UL-LISTED T3 SMOKE ALARMS.
The T3 pattern is an alarm signal that is on and off for 0.5 seconds three times in succession followed by a 1.5 second pause. The alarm would sound like this: “beep-beep-beep-pause” then “beep-beep-beep-pause” then “beep-beep–beep”. The Lifetone HL™ Bedside Fire Alarm and Clock will detect this T3 pattern and activate a loud, low and multiple frequency (520 Hz) alarm. Research has proven the 520 Hz alarm to be more effective at awakening and alerting individuals with hearing loss. In addition to the alarm sound, the Lifetone HL™ will activate the Lifetone Bed Shaker. Together, the Lifetone HL™ alarm and the Lifetone Bed Shaker provide effective awakening and alerting for individuals with hearing loss or the deaf.
The Lifetone HL™ Bedside Fire Alarm and Clock (“Lifetone HL™ Fire Alarm”) is an assistive alerting device intended for use in a residence by individuals with hearing loss or the deaf during a quiet environment and which is placed next to a bed or usual nighttime sleeping area. The Lifetone HL™ Fire Alarm will detect the T3 emergency signal given by existing, properly placed UL 217-listed smoke alarms and, when detected, will give its own emergency signal at a lower frequency (520 Hz), which may be heard by individuals with hearing loss in their beds. The product also gives its emergency signals visually through a display screen and through a tactile Bed Shaker, either of which may be detected by Deaf individuals in their beds. The Lifetone HL™ Fire Alarm is not intended for use in marine watercraft, recreational vehicles (“RV”), mobile homes, or hospitals.
-2-
II. Lifetone HL™ BEDSIDE FIRE ALARM and CLOCK
A. CONTROLS AND DISPLAY
1. Microphone grille and dust protector
2. Speaker – Must face pillow
1
WARNING! DO NOT COVER
AC POWER
3. Clock and Status Display
4. Wake Up Alarm and Clock Controls
5. Snooze/Light button
6. T est/Silence button
7. Battery Compartment
8. Optional Bed Shaker plug
Front View
9. Power Cord
23
6
TEST/SILENCE
T op View
1
4
5
Back View
7
BED SHAKER
8
9
Power Cord is located under Bed Shaker Plug.
B. FEATURES
1. A patented Hearing Sensor that constantly listens for and detects only UL-listed and NFPA recommended smoke alarms that emit a standardized T3 signal.
2. A low pitched alarm sound at 520 Hz that has been shown to be more effective for waking and alerting individuals with hearing loss.
3. A tactile alarm is provided in the form of the UL-listed Lifetone Bed Shaker that vibrates intermittently if there is an emergency alarm, and in a continuous manner for the wake-up alarm.
4. A Silence button that can silence the emergency alarm temporarily. If the smoke alarm is detected again the emergency alarm will sound again within 10-15 seconds.
5. In the event of a power failure, the Lifetone HL™ can operate in battery backup mode for at minimum 7 days and still provide emergency alarm signals.
6. As a safety feature, when AC or battery power is first applied, the Lifetone HL™ will require a test of your installed smoke alarms.
-3-
B. FEATURES (continued)
7. Other safety features and user status notifications include:
• If the Lifetone bed shaker is used, and becomes unplugged, the word “beds” and a flashing bed shaker icon will appear on the screen and a low frequency chirp will sound.
• If AC power is lost, the red power LED, located on the front left corner, will go out. In the left corner of the Display, an “ERROR” message and an AC plug icon will flash.
• If the batteries are too low or missing to support seven days of battery operation, the word “BATT” will appear on the screen in large text, a low pitched “chirp” will sound and the bed shaker will “twitch” at one minute intervals.
If the batteries are low or
missing, replace them immediately to ensure your safety.
ICON DESCRIPTION Generic error message AC Power is unplugged Batteries are low or missing
Bed shaker is unplugged or defective
Wake up alarm is activated
III. WARNINGS
READ AND UNDERST AND THESE WARNINGS BEFORE INSTALLING AND OPERATING YOUR LIFETONE HL™ BEDSIDE FIRE AL ARM AND CLOCK.
See Instructions in Section IV of the User’s Manual.
WARNING! ALWAYS install UL-listed T3 smok e alarms in pr oper locations in your home before operating the Lifetone HL™ Fire Alarm. Failure to verify that all existing smoke alarms are compatib le with this pr oduct may obstr uct proper operation, which may result in per sonal injury or death.
WARNING! FREQUENTLY TEST the Lifetone HL™ Fire Alarm to assure its proper operation with that of your existing smok e alarms. Failure to test this product fr equently may obstr uct its proper operation, which may result in personal injury or death.
WARNING! ALWAYS k eep noise levels in your home to a minimum of 70 dB or lower. Excessive noise levels may obstr uct the emer gency signals given b y your existing smoke alarm to the Lifetone HL™ Fir e Alarm, which may r esult in personal injury or death.
WARNING! DO NOT use the Lifetone HL™ Fire Alarm with acoustic sound-dampening wall or ceiling materials. These mater ials may reduce sound levels and obstruct the emergency signal given b y the pr oduct, which may result in personal injury or death.
-4-