Lifesmart LS-946 Owner’s Manual

LS-946
Blood Glucose Plus ß-Ketone Monitoring System
Owner’s Manual
Version 1.0 2017/01 311-4279400-001
Dear LifeSmart 2 LS-946 System Owner:
Thank you for purchasing the LS-946 Blood Glucose Plus ß-Ketone Monitoring System. This manual provides important information to help you to use the system properly. Before using this product, please read the following contents thoroughly and carefully.
The System measures both blood glucose and β-ketone. Regular monitoring of your blood glucose and β-ketone levels can help
you and your doctor gain better control of your diabetes. Due to its compact size and easy operation, you can use the LS-946 Blood Glucose Plus ß-Ketone Monitoring System to easily monitor your
blood glucose and β-ketone levels by yourself anywhere, any time.
If you have other questions regarding this product, please contact the local customer service or place of purchase.
Intended Use
This system is intended for use outside the body (in vitro diagnostic use) by people with diabetes at home as an aid to monitoring the effectiveness of diabetes control. It is intended to be used for the quantitative measurement of glucose (sugar) in fresh whole blood
samples from the finger, and to measure β-hydroxybutyrate (ketone)
in fresh whole blood samples from the finger and palm. It should not be used for the diagnosis of or screening for diabetes mellitus.
The test for haematocrit (HCT) as part of the system, is intended for use in the in vitro quantification of packed red blood cell volume fraction in capillary whole blood as an aid in monitoring the status of total volume of red blood cells. The test reading of haematocrit (HCT) is used only to determine whether the blood test sample is within the acceptable range of Blood Glucose Plus ß-Ketone monitoring system. It should not be used for the diagnosis of anaemia or erythrocytosis.
3
IMPORTANT SAFTY INSTRUCTIONS
READ BEFORE USE
1. Use this device ONLY for the intended use described in this manual.
2. Do NOT use accessories which are not specied by the manufacturer.
3. Do NOT use the device if it is not working properly or if it is damaged.
4. This device does NOT serve as a cure for any symptoms or diseases.
The data measured is for reference only. Always consult your doctor to
have the results interpreted.
5. The blood glucose test strip can be used for the testing of newborns;
The β-ketone test strip must not be used for the testing of newborns.
6. Before using this device to test blood glucose or β-ketone, read all
instructions thoroughly and practice the test. Carry out all the quality
control checks as directed.
7. Keep the device and testing equipment away from young children.
Small items such as the battery cover, batteries, test strips, lancets
and vial caps are choking hazards.
8. Use of this instrument in a dry environment, especially if synthetic
materials are present (synthetic clothing, carpets etc.) may cause
damaging static discharges that may cause erroneous results.
9. Do NOT use this instrument in close proximity to sources of strong
electromagnetic radiation, as these may interfere with accurate
operation.
10. Proper maintenance and periodic control solution testing are essential
to the longevity of your device. If you are concerned about your
accuracy of measurement, please contact the local customer service
or place of purchase for help.
KEEP THESE INSTRUCTIONS IN A SAFE PLACE
4
TABLE OF CONTENTS
BEFORE YOU BEGIN 09
Important Information 09
Meter Overview 10
Display Screen 11
Test Strip 11
SETTING THE METER 12
THE THREE MEASURING MODES 13
QUALITY CONTROL TESTING 14
Calibration 14
How to Code Your Meter (for β-Ketone Test) 14
Checking the Code Number 14
Performing a Control Solution Test 16
TESTING WITH BLOOD SAMPLE 17
Preparing the Lancing Device for Blood Testing 17
Preparing the Puncture Site 17
Performing a Blood Glucose or β-Ketone Test 18
Alternative Site Testing (for β-Ketone Test) 20
METER MEMORY 21
Reviewing Test Results of Blood Glucose or β-Ketone 21
Reviewing Blood Glucose Day Average Results 21
BLUETOOTH PAIRING 22
MAINTENANCE 23
Battery 23
Caring for Your Meter 24
Caring for Your Test Strips 24
Important Control Solution Information 25
5
SYSTEM TROUBLESHOOTING 26
Result Readings 26
Error Messages 27
Troubleshooting 28
DETAILED INFORMATION 29
SYMBOL INFORMATION 30
SPECIFICATIONS 31
6
(a) (b) (c)
832
T
E
S
(e) (f) (g) (h)(d)
(i)
(k) (l)
832
832
7
(m)
(n)
(j) (o)
1
2
8
BEFORE YOU BEGIN
Important Information
● Severe dehydration and excessive water loss may cause readings
which are lower than actual values. If you believe you are suffering from severe dehydration, consult a healthcare professional immediately.
● If your blood glucose or β-ketone results are lower or higher than usual, and you do not have any symptoms of illness, rst repeat the
test. If you have symptoms or continue to get results which are higher or lower than usual, follow the treatment advice of your healthcare professional.
● Use only fresh whole blood samples to test your blood glucose or β-ketone. Using other substances will lead to incorrect results.
● If you are experiencing symptoms that are inconsistent with your blood glucose or β-ketone test results and you have followed all the
instructions given in this owner’s manual, contact your healthcare professional.
● We do not recommend using this product on severely hypotensive
individuals or patients in shock. Please consult your healthcare professional before use.
● The measurement unit used for indicating the concentration of
blood or plasma glucose will have molarity (mmol/L). The
approximate calculation rule for conversion of mmol/L in mg/dL is:
mg/dL
mmol/L
For example:
1) 120 mg/dL ÷ 18 = 6.6 mmol/L
2) 7.2 mmol/L x 18 = 129 mg/dL approximately.
● The HCT is the volume percentage (%) of red blood cells in blood
sample.
(Note: Haematocrit =HCT)
Divided by 18
Times 18
= mmol/L
= mg/dL
9
Meter Overview
2
5
3
4
Top
1
SET
7
6
8
1
Test Strip Slot
Front
Right SideLeft Side Back
Insert test strip here to turn the meter on for testing.
2
Bluetooth Indication Light
3
Display Screen
4
Main Button (M)
Enter the meter memory and silence a reminder alarm.
5
Test Strip Ejector
Eject the used strip by pushing up this button.
6
Bluetooth Switch
Activating the Bluetooth function.
SET Button (S)
7
Enter and conrm the meter settings.
8
Battery Compartment
10
Display Screen
1
Ketone Symbol / Ketone Warning
2
Glucose Level / Ketone Level
3
Error Warning
4
Low Battery Symbol
5
Day Average
6
Memory Symbol
7
Time / Date
8
HCT Level
Glucose / Ketone Measurement
9
Unit
10
Measurement Modes
Gen – any time of day
AC – before meal
PC – after meal
11
Test Strip Symbol
12
Blood Drop Symbol
13
Code
14
Glucose Symbol
15
Alarm reminder
13 12 11
14
1
2
3
4
5
6
10
15
9
8
Test Strip
7
1
2
3
4
(for glucose test) (for ketone test)
NOTE:
The LS-946 monitor should only be used with LS-946 Glucose or β-Ketone
Test Strips. Using other test strips with this meter can produce inaccurate
results.
1
Absorbent Hole
2
Conrmation Window
ATTENTION:
The front side of test strip should
face up when inserting test strip.
Test results may be wrong if the contact
bar is not fully inserted into the test slot.
3
Test Strip Handle
4
Contact Bars
11
Loading...