Kit Instruction for Treadmill T3/T5 Heart Rate Kit (6917601)
Tools Required: Phillips Screwdriver, High Adhesive Tape
1. At the power switch, turn OFF the unit, then
unplug the line cord at the wall outlet.
2. Remove ten(10) screws from the back of the
console and lift off the overlay assembly.
3. Disconnect the main wire harness from the
connector on the left side of the overlay
assembly.
4. Remove the overlay assembly from the console
pan.
5. Remove the adhesive backing f rom the dual lock
tape and place it in the console bay.
6. Place the isolator tube in the console bay with
the dual lock tape facing down against the dual
lock in the console bay and press firmly.
7. Insert the HR cable connector into the 3 pin
connector recepticle.
8. Push the telemetry receiver to front of console.
9. Tape excess HR cable to underside of the
overlay assembly.
10. Connect the main wire harness to the lef t side of
the overlay assembly.
Display
Board
PCB
3 Pin
Connector
Dual Lock
Adhesive Tape
HR Cable
Connector
Telemetry
Receiver
Foam
Cover
Dual Lock
Adhesive Tape
Isolator
Tube
11. Reinstall ten(10) screws in back of console .
If you have any questions or comments, please call Life Fitness Customer service at: 1-800-328-9714
Pub No. 6980101