Lifebreath 195ECM User Manual

Date: ___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#: _________________________________________
Submitted by: ____________________________________
ENGINEERING DAT A
THERMALLY CONDUCTIVE,PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two airstreams. The two cores are arranged for highly efficient counter current airflow.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common ECM motor. 5 speed fan operation. 120 VAC, 1.4 Amps.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV
Four threaded inserts at corners of case designed to accept four reinforced polyester straps that are supplied with the unit.
DEFROST
Damper defrost system.
DEHUMIDISTAT
Adjustable Internal Dehumidistat.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to prevent exterior condensation. Drain connections 2 - 1/2" (12 mm) OD.
CONTROLS
ControlAir 15 - Standby/ON mode, 20 ON/ 40 OFF mode (each mode has 5 speeds). Control pad can be removed from HRV and remotely mounted.
Weight 106 lbs. (48 kg) Shipping Weight 108 lbs. (49 kg)
All units conform to CSA and UL standards.
Model 195ECM
DIMENSIONS 195ECM inches (mm)
*Sensible Efficiency – thermal **Latent Efficiency – moisture
Note: Effectiveness - based on temp. differential between the 2 airstreams Efficiency – takes into account all power inputs
Performance
Net supply air flow in cfm (L/s) against external static pressure
E.S.P
(external static pressure) [cfm (L/s)]
@ 0.1" (25 Pa) 171 (81)
@ 0.2" (50 Pa) 164 (77)
@ 0.3" (75 Pa) 156 (74)
@ 0.4" (100 Pa) 143 (67)
@ 0.5" (125 Pa) 134 (63)
@ 0.6" (150 Pa) 126 (59)
@ 0.7" (175 Pa) 119 (56)
Max. Temperature Recovery 88%
Sensible Effectiveness @ 114 cfm (54 L/s) 32°F (0°C) 88%
*Sensible Efficiency @ 114 cfm (54 L/s) 32°F (0°C) 81%
*Sensible Efficiency @ 119 cfm (56 L/s) -13°F (-25°C) 77%
VAC @ 60HZ 120
WATTS / Low speed 34
WATTS / High speed 95
Amp rating 1.4
OPTIONAL MAIN CONTROLS 99-350 Lifestyle Ventilation Control 7/24 programmable ventilation, (3 wire) 20
gauge wire (min.) 100’ length
99-109 Air Sentry Air Quality Monitor designed to accept remotely mounted
Control Pad, (3 wire) 20 gauge wire (min.) 100’ length
99-250 Ventilation Dehumidistat designed to accept remotely mounted Control
Pad, (4 wire) 20 gauge wire (min.) 100’ length
OPTIONAL TIMERS 99-104 Digital Electronic Timer - initiates high speed ventilation for 20, 40 or 60
minutes, (3 wire) 20 gauge wire (min.) 100’ length
99-101 Crank Timer - Initiates high speed ventilation for up to 60 minutes, (2 wire)
20 gauge wire (min.) 100’ length
OPTIONAL ACCESSORIES 99-163 Duct Heater w/ Electronic SCR Thermostat, 1 Kw, 6” (150 mm)
99-164 Duct Heater w/ Electronic SCR Thermostat, 2 Kw, 6” (150 mm) 99-185 Weatherhoods, Two - 6” (150 mm) c/w 1/4” (6 mm) mesh screen WARRANTY
Units carry a LIFETIME warranty on the heat recovery core anda5yearreplacement parts warranty.
TI-195ECM
TO OUTSIDE
METAL CLASPS
FILTER
MOTOR
FROM INSIDE
220
200
180
160
140
120
100
Air Flow (cfm)
80
60
40
20
0 0.1 0.2 0.3 0.4 0.5 0.6 0 .7 0.8
Static Pressure (in w.g.)
Por ts
6" (150 mm)
FILTER
FRESH AIR
FROM OUTSIDE
DEFROST
DAMPER
DEFROST AIR FROM INSIDE
CONDENSATE
DRAINS
49 "
(1245)
Por ts
7" (178 mm)
BLOWERS
FRESH AIR
TO INSIDE
*NOTE: Front clearance of 25 inches (635 mm) is recommended for servicing unit.
ATTENTION
19"
(483)
14 3/4"
(375)
The ECM motor produces a tone that some may find objectionable. We recommend the installation of the optional 99-SILENCER6 on the ‘Stale Air from Inside’ and ‘Fresh Air to Inside’ ducts.