Lifan Wiltec 92494, Wiltec 92493, Wiltec 92495, Wiltec 92492, Wiltec 92491 User Manual

Manual
Gasoline-Waterpump
Articel 92494 92492 92493 92495 92491
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved! Due to further developments, illustrations, functioning steps and technical data can differ insignificantly.
© by WilTec Wildanger Technik GmbH Seite 1 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de
The information contained in this document is subject to change without prior notice. No part of this document can be copied or duplicated in another form without the prior written consent of WilTec Wildanger Technik GmbH. The WilTec Wildanger Technik GmbH assumes no liability for any errors in this user manual or the connection diagram. Although WilTec Wildanger Technik GmbH has made every effort to make sure that this user manual is complete, accurate and updated, errors cannot always be avoided. In the event of problems with this user manual please complete and send this form back to us.
FAX-notification (+++49 2403 55592-15),
from: ________________________________________
Name: ________________
Firm:_____________________
Tel/Fax:__________________
I would like to report the following mistakes:
_______________________________ ____________________________________
Customer Service WilTec Wildanger Technik GmbH e-mail: service@WilTec.info Tel:++ +49 2403 55592-0
Introduction
Thank you for purchasing this quality product. To minimize the risk of injury we urge that our clients take some basic safety precautions when using this device. Please read the operation instructions carefully and make sure you have understood its content.
The electric part of the device contains no parts that can be inspected or serviced by the user. Leave the maintenance, adjustment and repair to qualified technical personnel. In case of unauthorised intervention the 2-year warranty is no longer valid! Keep these operation instructions safe.
© by WilTec Wildanger Technik GmbH Seite 2 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de
IMPORTANT NOTICES
Please pay special attention to statements preceded by the following words:
WARNING:
A warning is used to alert the user to fact that hazardous operating and maintenance procedures may result in injury to or death of personnel if not strictly observed.
CAUTION:
A caution is used to alert the user to fact that hazardous operation and maintenanceprocedures may result in injury to or death of personnel if not strictly observed.
NOTE:
Give helpful information.
This manual is filled with important safety information — please read it carefully. This manual should be considered as a permanent part of the water pump set and should remain with the water pump set when resold.
1. SAFETY GENERAL RULES
Before operating, read the manual carefully and be sure to become familiar with it, otherwise personal injury of death as well as severe parts damage may occur.
Before operating, perform the pre-operation inspection to make your operation on the
waterpump safer.
For the sake of safety, it is forbidden to pump inflammable or corrosive liquids (such as
gasoline or acid). Similarly, be sure not to pump corrosives such as seawater, chemical solution, and alkaline liquids.
Locate the water pump on a firm and level ground. A sloped or over turned water pump may
result in fuel spilled out.
Operate a water pump in a well-ventilated place without fire resources and keep it at least
one meter from other devices.
Because touching hot parts of the engine may get severe burns when operating the water
pump, keep children and pets far away from the operating site.
Master the method to quick stop the water pump; learn manipulating control devices. Using
the water pump without following the instructions in the manual is forbidden.
WARNING:
Gasoline is extremely inflammable and explosive in certain conditions.
Filling gasoline in a well-ventilated place with engine stalled. In gasoline filling and storage sites, be sure there are no smoking and fire resources such as flame, fire spark and so on.
Do not spill gasoline out of the fuel tank. After filling, make sure to tighten the fuel filler cap.
When filling, avoid spilling gasoline out, for spilled gasoline and gasoline vapor is prone to ignite. Once gasoline is spilled out, make sure to wipe it up before operation.
© by WilTec Wildanger Technik GmbH Seite 3 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de
Don’t run the engine in an enclosed room and poor-ventilated place, since exhaust emission from the engine contain toxic carbon monoxide (CO), which may make people lose consciousness, even lead to death.
2. PARTS DESCRIPTION
(Fig.1)
3. PRE-OPERATION PREPARATION
3.1 Connecting water inlet pipe
Use commercially available hose, hose joint and clamp. The water inlet hose must be of continuous structure and be non-folded. The length of the hose should be as the same as or not more than that required. The effect of suction is greater the shorter distance from the water surface. Suction time varies with the length of the water inlet hose in direct ratio. The filter matching with the water pump should be mounted to the end of the water inlet hose with a hose clamp.
(Fig.2)
CAUTION:
Before pumping, install the filter securely to the end of the water inlet hose. The filter flits any impurity, which may produce passage jam to damage impellers.
Be sure to install the hose joint and clamp well so as to prevent from air leaks and pumping performance drop; loose water inlet hose will decrease the water pump performance and self-suction ability.
© by WilTec Wildanger Technik GmbH Seite 4 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de
3.2 Connecting the water outlet hose
Use commercially available hose, hose joint and clamp. A short hose with a big diameter is the best. A long hose with small diameter will increase flowing resistance and decrease the power output of the water pump.
NOTE Tighten the hose clamp to avoid falling off under high pressure.
3.3 Engine oil level check
CAUTION:
The quality of the engine oil is one of the key factors in deciding engine performance and service life. Not apply filthy engine oil or vegetable oil.
Be sure to check engine oil level with the engine stalled and stand vertically in level ground.
Use 4-stroke gasoline engine oil engine oil equivalent in quality with SF, SG from API. Oil velocity varies with average temperature; please select engine oil with proper velocity according to your local temperature.
ENGINE OIL ALARM SYSTEM
The engine oil alarm system is intended to avoid engine damage due to engine oil too low in the crankcase.
(Fig.3)
Before the engine oil level in the crankcase drops down below the safety line, the alarm system will turn off the engine automatically (while the engine switch keeps at ON). If the engine stops and cannot restart, check the engine oil level first.
Remove the engine oil dipstick and wipe it clean; Re-insert the dipstick into engine oil filler hole but not screw it in, and then take it out to check the engine oil level; if the engine oil level is too low, fill specified engine oil up to the top of the filler hole.
© by WilTec Wildanger Technik GmbH Seite 5 http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de
Loading...
+ 9 hidden pages