Lifa Air LAC100, LAC52 User Manual

Designed in Finland
LAC100 Smart Car Air Purifier
Please read this user manual before using the product, and keep securely for future reference.
IB-200-LAC100-01 V1.0
International Limited
Manufactured by Dongguan LIFAair Technology Ltd. Address: No. 2, East Industry Road, Songshan Lake Science & Technology Industrial Park, Dongguan, 523808, CHINA www.lifaair.com Designed in Finland
② ③
EN · Preface
Smart controller Strap
Important safety information
Packing list
Main unit
1
Thank you for selecting LIFAair! You are about to enjoy superior Finnish technology and innovation for quality living.
Product Description
Smart controller
2
Main unit (Purifier)
NOTE: Do not block the air inlet and outlet as the PM2.5 and CO2 sensors are located in the center of the purifier.
NOTE: Above diagrams are for reference only, please prevail in kind.
• Please do not operate product while driving to avoid accidents.
• Only use attachments/accessories as specified by the manufacturer.
• Keep product away from children in case of accidents.
• Do not obstruct the air inlet and outlet.
• Protect the power cord from being twisted, bent, or pinched.
• Unplug the product from the lighter socket when not in use.
• Please unplug the controller from the lighter socket before changing filters, moving, or cleaning pre-filter.
• Never sit or lean on the purifier to avoid accidents and/or damage.
• Please do not pamper with the exterior parts and/or the air inlet and outlet.
• Please do not place the product directly under the air conditioner to avoid condensed water.
• Except for professional maintenance personnel, please do not attempt to repair the product.
NOTE:
* To operate the device, please insert the controller fully in the lighter socket, and twist to lock position. * The main unit must be fully secured around the headrest. * While driving and/or the device is operating, please do not touch/play with the unit to avoid accidents. * Please turn off the de vice during periods when the windows are open. The product will be ineffective during this time, and will only exhaust the lifespan of the filters. * Please alternate between recirculation and external circulation to achieve a healthy in-car air quality level. Exter nal circulation can reduce carbon dioxide levels, while recirculation and the product together can lower PM2.5 concentration.
Main unit x 1 Power supply/smart controller x 1 Strap x 1 User manual / cer tificate x 1
User manual /
certificate
* Tips: For cars where the power socket remains connected to a power source even after the engine is tur ned off, please manually turn off the
purifier. When the engine starts again, you can manually turn on the purifier. To ensure your car battery is not depleted, the purifier will automatically enter standby mode when voltage is low.
. DC power source connector Note: Please do not insert other connecters to avoid damage.
. Insert strap here. PM2.5 and CO
2 sensors
. Trademark
. Display screen. USB current output 1 (5V 2A). USB current output 2 (5V 1A). DC power source/control connector
(connect to main unit) . Lighter plug
Correct disposal of this product. This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the r eturn and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
English
CO21500
500
PM2.535
10
Spin into
Settings
settings
Settings
Smart Controller Display Interface
How to Operate Smart Controller
4
NOTE: Above diagrams are for reference only, please prevail in kind.
Initial Installation
Take out the strap from the accessories box; thread the strap through the plastic seals on the back of the purifier.
Direction of stra p
4
3
1
2 3
5
Remove the driver’s seat headrest. Secure the strap around the harness of the headrest, reinstall the headrest.
Connect the power supply/control port of smart controller to DC power source socket on purifier.
PM2.5 mode
CO2 mode
SETTING mode SETTING mode
There are 2 main methods (press and spin), subdivided into 5 distinct actions to operate the smar t controller: spin, quick spin, press, double press, and press and hold.
Spin Press
Adjust the USB connector of smar t controller, then insert it into car power socket and start the car. If the contents on the display window are not easy to read, you can adjust the display on the menu.
Spinning is independent of direction; the differentiation between slow and fast spin is based on speed.
Press: Press the screen once Press and hold requires to maintain contact up to 2 seconds.
Display
1. PM2.5 interface displays PM2.5 concentration in the air (μg/m3); The standard level is given below (Chinese standard is 35μg/m3).
2. CO
2 interface displays carbon dioxide concentration (ppm). The standard
level is given below.
3. SETTINGS: Quick spin the dial to enter sub-menu.
Main menu
EnglishEnglish
Loading...
+ 4 hidden pages