10Installing the appliance in the recess..................6
11Disposing of packaging........................................6
12Connecting the appliance.....................................6
The manufacturer works constantly on the further development
of all the types and models. Therefore please understand that
we have to reserve the right to make design, equipment and
technical modifications.
To get to know all the benefits of your new appliance, please
read the information contained in these instructions carefully.
The instructions apply to several models. Differences may
occur. Text relating only to specific appliances is marked with
an asterisk (*).
Instructions for action are marked with a , the results of
action are marked with a .
1 General safety information
-
Only install, connect and dispose of the appliance according to the instructions. Take
particular note of “Recess dimensions” (see 5)
and “Ventilation of the kitchen unit” (see 7) .
-
The socket must be easily accessible so that
the appliance can be quickly disconnected
from the supply in an emergency. It must be
outside the area of the rear of the appliance.
DANGERidentifies a situation involving direct
danger which, if not obviated, may
result in death or severe bodily
injury.
WARNINGidentifies a dangerous situation
which, if not obviated, may result in
death or severe bodily injury.
CAUTIONidentifies a dangerous situation
which, if not obviated, may result in
minor or medium bodily injury.
NOTICEidentifies a dangerous situation
which, if not obviated, may result in
damage to property.
Noteidentifies useful information and tips.
2 Transporting the appliance
Risk of injury and danger of damage as a result of incorrect
transport!
u
u
u
CAUTION
Transport the appliance in a packed condition.
Transport the appliance upright.
Do not transport the appliance without assistance.
3 Installing the appliance
Risk of fire due to short circuit!
If the mains cable/connector of the appliance or of another
appliance touch the rear of the appliance, the mains cable/
connector may be damaged by the appliance vibrations,
leading to a short circuit.
u
u
Fire hazard due to dampness!
If live parts or the mains lead become damp this may cause
short circuits.
u
u
Fire hazard due to refrigerant!
The refrigerant R 600a is environmentally friendly but flammable. Escaping refrigerant may ignite.
u
Fire hazard and danger of damage!
u
NOTICE
Risk of damage from condensation!
If your appliance is not a Side-by-Side (SBS) appliance:
u
If your appliance is a Side-by-Side (SBS) appliance:
u
q
q
q
q
WARNING
Stand the appliance so that it is not touched by connectors
or main cables.
Do not plug the appliance or any others into sockets located
near the rear of the appliance.
WARNING
The appliance is designed for use in enclosed areas. Do not
operate the appliance outdoors or in areas where it is
exposed to splash water or damp conditions.
Only use the appliance when it is installed.
WARNING
Do not damage the piping of the refrigeration circuit.
WARNING
Do not place appliances emitting heat e.g. microwaves,
toasters etc. on the appliance!
do not install the appliance directly next to another fridge/
freezer.
install the SBS fridge-freezer combination according to the
accompanying sheet.
In the event that the appliance is damaged, contact the
supplier immediately before connecting to the mains.
The floor at the site must be flat and level.
Do not install the appliance in a location where it is exposed
to direct radiation of the sun, next to a cooker, heater and
similar.
Do not install the appliance alone: it is best to work together
with two or more people.
2* Depending on model and options
The
q
q
If the transport lock is inserted on the door:
u
If the transport lock is screwed onto the door:
u
installation area of your appliance must demonstrate,
per 8 gof refrigerant R 600a, a volume of 1 m3 according to
the EN 378 standard. If the installation area is too small, an
inflammable gas-air mixture may arise as a result of a
leakage in the refrigeration circuit. Information as to the
refrigerant amount can be found in the type plate on the
inside of the appliance.
If the appliance is installed in a very damp environment,
condensed water may form on the outside of the appliance.
Always make sure that there is good ventilation - both at air
inlet and outlet - at the site of installation.
Pull off red transport lock.
Unscrew
Close the freed retaining hole
with plugs (60).
appliance is built-in and therefore completely enclosed by
The
a kitchen unit. The kitchen unit concerned must be built exactly
to the prescribed dimensions and allow for sufficient ventilation, both at air inlet and outlet, to ensure proper appliance
operation.
After installation:
Remove
u
parts etc.
Note
Clean the appliance (see Operating Instructions,
u
Chapter "Cleaning the appliance").
protective films, adhesive tapes and transport lock
tion, two appliances next to one
another, build the appliances into
separate kitchen units.
Check the wall thickness of the adjoining cabinets: it must
u
be min. 16 mm.
Only install the appliance in robust, stable kitchen units.
u
Secure the units against tipping.
Align the kitchen unit using a spirit level and marking square
u
and if necessary compensate with shims.
Ensure that the floor and walls of the unit are at right angles
u
to one another.
6 Unit door
Two doors are required for this kitchen unit: the upper for the
-
refrigerator and the lower for the freezer compartment.
The doors must be minimum 16 mm and maximum 19 mm
-
thick.
When both doors are closed, the gap between the upper
-
and lower door must be at least 3 mm high.
The gap between unit doors must be at the same level as
-
the gap between the appliance doors.
There must be a gap of minimum 3 mm in height between
-
the door and the unit door located above it (if one exists).
The width of the unit doors depends on the style of the
-
kitchen and on the gap size between the door panels of the
cabinet. Generally, there should remain a vertical gap of
3 mm between the unit doors.
The top edges of the upper and lower doors should be on a
-
level with the doors of the adjoining cabinet (or cabinets), if
there are other cabinets.
The unit doors must be planar and mounted stress-free.
-
NOTICE
Risk of damage from over-heavy unit door!
If the unit door is too heavy, damage to the hinges and resulting
impairment of function cannot be excluded.
Before mounting the unit door, make sure that the door does
u
not exceed the approved unit door weight.
7 Ventilation of the kitchen unit
There must be an effective ventilation shaft of at least
-
200 cm2 per appliance at the air inlet
Fig. 3 (B)
The principle applies that the larger the ventilation shaft, the
-
more energy-saving the operation of the appliance.
The depth of the ventilation shaft at the back of the cabinet
-
must be min. 40 mm.
vent.
Fig. 3 (A)
and outlet
Fig. 3
Appliance typeMaximum unit door weight (kg)
Refrigerator
compartment
door
ICP 29..1312
ICU 33.., ICUN 33..,
ICP 33.., ICN 33..,
SICN 33..,
ICNP 33..
ICBP 32..1912
ICBN 33..,
SICBN 33..
1412
2012
Freezer compartment door
The upper ventilation shaft can either be positioned directly
-
above the appliance with an optional ventilation grille
Fig. 4 (C)
an air outlet opening in a false ceiling
, close to the ceiling above the unit
Fig. 4 (E)
Fig. 4 (D)
.
Fig. 4
or as
4* Depending on model and options
Changing over door hinges
8 Changing over door hinges
NOTICE
Risk of condensation damage for Side-by-Side appliances!
Certain appliances can be set up as Side-by-Side combinations (two appliances next to each other).
If your appliance is a Side-by-Side (SBS) appliance:
Set up the SBS combination in accordance with the
u
enclosed document.
If the positioning of the devices is stipulated:
Do not change the door hinges over.
u
Risk of injury if soft stop contracts!
u
Risk of injury if hinges fold!
u
Risk of injury due to the door dropping out!
If the fastening parts are not screwed into place firmly enough,
the door may drop out. This may lead to severe injuries. What
is more, the door may not close and therefore the appliance
may fail to cool properly.
u
u
u
Note
The door hinges can only be changed over if there is sufficient
space towards the top to pull out the hinge mounting bracket
and to mount it again on the other side. This is generally not the
case after installation in the recess.
u
CAUTION
Carefully remove the soft stop mechanism.
CAUTION
Leave hinges open.
WARNING
Screw the hinges and the ball journal of the soft stop mechanism firmly into place, with 4 Nm.
Screw the holder of the soft stop mechanism firmly into
place, with at least 3 Nm.
Check all of the screws and retighten if necessary.
Change the hinges over before the appliance is installed in
the recess.
There is a risk of injury during this stage! Please
observe the safety instructions!
The instructions apply to several models. Only carry
out this step if it is relevant for your appliance.
9 Water connection*
Danger of electric shock!
u
u
u
Risk of poisoning!
u
u
- The water pressure has to be between 0.15 MPa and
- The water supply to the appliance must be via a cold water
- Between the hose and the domestic water connection there
- All the fixtures and fittings used for water supply have to
- Do not damage or kink the water inlet pipe when installing
WARNING
Disconnect the appliance by unplugging it before you
connect it to the water line.
Shut off the water supply before you connect the water feed
lines of the IceMaker.
The connection to the drinking water system may be carried
out only by a qualified gas fitter and plumber.
WARNING
The water quality has to comply with the drinking water ordinance of the respective country (e.g. 98/8
The IceMaker serves exclusively for making ice cubes in
household quantities and has to be operated with water suitable for the purpose.
Fig. 5
0.6 MPa (1.5 bar - 6 bar).
pipe which withstands the operating pressure and complies
with the hygiene regulations.
Use the accompanying stainless steel hose (1.5 m). Do not
reuse old hoses. A 3 m hose is available from the customer
service department and has to be fitted by an expert.
In the hose connecting piece is a sieve with seal.
has to be a stopcock to interrupt the water supply in case of
need.
comply with the applicable regulations of the respective
country.
the appliance.
Choose between the alternatives given.
Loosen the screws only, do not undo them all the way.
Check the screws and tighten if necessary.
While changing over the door hinges, observe the safety
u
instructions above and also the information in the symbols
key.
Change the hinges over as shown at the end
of the book.
Fig. 6
The solenoid valve is at the bottom back of the appliance. It
has a metric R3/4 connecting thread.
Connect the straight part of the stainless steel hose to the
u
solenoid valve.
Fix the stainless steel hose to the housing with the locking
u
hook.
* Depending on model and options5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.