Liebert MP2-220K Product Data Sheet

AC Power Systems For Business-Critical Continuity
Liebert MicroPOD
Wrap-Around Maintenance Bypass With Output Distribution
When a computer system cannot be without power — even for maintenance —
a Liebert MicroPOD
ensures continuous uptime. The Liebert MicroPOD
Liebert GXT and Liebert PSI UPS models 3 kVA and below, as well as other
brands of UPS systems. It allows removal of the UPS without powering down
the connected equipment.
The Liebert MicroPOD maintenance bypass and power output
distribution switch allows you to manually transfer the connected
equipment to utility power via a maintenance bypass switch,
permitting scheduled maintenance or UPS replacement without
discontinuing power to the critical load. Transferring back to UPS
power is just as easy — simply turn the switch to the indicated
position and the load is protected by the UPS. Available in plug-and-
play or hardwired options at 120V or 208V rating, units include
brackets for rack mounting in any direction.
Key Benefits:
Higher Availability
Provides utility power to attached equipment when switched to maintenance bypass mode.
Allows UPS maintenance or replacement of the UPS without discontinuing power to critical equipment.
Flexibility
Easily installed — the UPS and utility power are both connected to the MicroPOD with the supplied cords.
Allows scheduled UPS maintenance to ensure continuous uptime without having to shut down protected equipment.
Rotary switch with indicators make the unit simple to operate.
Plug-and-play connectability for both input and output.
Compatible with any brand of UPS system.
Lowest Total Cost Of Ownership
Assures system uptime during maintenance activities.
Extreme affordability.
o-year, no-hassle replacement
w
T warranty eliminates the cost of replacement during the warranty
iod.
r
pe
U
U
®
L
c
®
L
OUTPUT
UPS
PUSH TO RESET
UPS
A
VAILABLE
UPS
UTILITY
MAINTENANCE BYP
ASS
AVAILABLE
CONNECT UPS
LINE CORD HERE
PUSH TO RESET
IF UTILITY LAMP IS IL
LUMINATED MAINTENANCE BYPASS POSITION MAY BE SELECTED
SWITCH TO UPS POSITION ONLY WHEN UPS LAMP IS ILLUMINATED
CAUTION
OUTPUT
UTILITY
15 A M P
15 A M P
From Utility
Protected
Devices
MicroPOD plugs into UPS outlet
UPS plugs into MicroPOD
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
.
AC Power
Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection
Liebert Corporation
1050
Dearborn Drive
P.O.
Box 29186
Col
umbus, Ohio 43229
800 877 9222
Phone (U.S. &
Canada Onl
y)
614 888 0246
Phone (Outside U.S.)
614 841 6022
FAX
Via
Leonardo Da Vinci 8
Zona
Industriale Tognana
35028
Piove Di Sacco (PD)
Ital
y
39 049 971
9 111 Phone
39 049 584
1 257 FAX
Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 G
loucester Rd, Wanchai
Hong
Kong 852 25722201 Phone 852 28029250 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone 614 841 6755 (outside U.S.)
MicroPOD
art Number Plug to Utility UPS Input UPS Output Output Receptacles
P
MP2-115A
pecifications
S
eceptacle to Plug to MicroPOD
R
isted MicroPODs
120V UL L
5-15P 5-15R 5-15P (8)5-15R MP2-120C 5-20P 5-20R 5-20P (8)5-20R (T-Slot) MP2-130C
L5-30P L5-30R L5-30P (8)5-20R (T-Slot)
MP2-130E L5-30P L5-30R L5-30P (2)5-15R, (4) 5-20R (T-Slot)
(1) L5-30R
MP2-130P
L5-30P L5-30R L5-30P (4) 5-15R, (2) L5-20R MP2-115HW Hardwired 5-15R 5-15P Hardwired MP2-120HW
Hardwired 5-20R 5-20P Hardwired
MP2-130HW Hardwired 5-30R 5-30P Hardwired
isted MicroPOD
208V UL L
L6-20P OR (2) L6-20R, (2) L6-15R,
Hardwire Connection OR Hardwire Connections
MP2-220N
(plug is removable for L6-20R L6-20P (receptacles are removable
ardwire applications) for hardwire applications)
h
arked MicroPODs
230V CE M
MP2-210K EN60320/C14 EN60320/C13 EN60320/C14 (4) EN60320/C13 MP2-220L EN60320/C20 EN60320/C19 EN60320/C20 (4) EN60320/C13, (1)EN60320/C19
Configuration
The MicroPOD plugs into the utility and UPS, and the UPS is plugged into the MicroPOD. All protected devices are connected to the MicroPOD, allowing maintenance bypass for the UPS.
e e
l
Whi completeness in this literature, Liebert Corporation assumes no
ponsib
s
e
r
om u
r
f
© 2007 Liebert Corporation. All rights reserved throughout the w
ame
All n of their respective owners.
ebert and the Liebert logo are registered trademarks
® Li of the Liebert Corporation.
SL-23800 (R02/07) Printed in USA
aution has been taken to ensure accuracy and
ec
y pr
r
e
v
lity, and disclaims all liability for damages resulting
i
mation or for any errors or omissions.
or
f
f this in
e o
s
orld. Specifications subject to change without notice.
s referred to are trademarks or registered trademarks
usiness-Critical Continuity
B
r an
e
w
o
P are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.
rson Network Power logo
d the Eme
, Eme
rson Network
Loading...