Features:
36” Diameter Fiberglass TankAvailable in 48”, 60”, 72”, 84”, and 96” heights  LSG Single or LSGX 2 Stage 2HP Grinder Pumps  Factory Installed Guide Rail System  Quick Tree pre-mounted float system  NEMA 4X Junction Box  NEMA 4X Duplex Alternating Control Panel
Contents
1. General Information
2. Precautions / Pre-Installation
3. Installation Instructions
4. Maintenance & Troubleshooting
5. GR20 Assembly
D3600- Series Duplex Grinder Systems
7000 Apple Tree Avenue Bergen, NY 14416 Phone: (800) 543-2550 Fax: (585) 494-1839 www.libertypumps.com
©Copyright 2013 Liberty Pumps Inc. All rights reserved 1
1 General Information
GRINDER PUMP SPECIFICATIONS
MODEL
H P
VOLTAGE
POWER
CYCLE
(Hz)
PHASE
FULL LOAD
AMPS
LOCKED
ROTOR
AMPS
THERMAL
OVERLOAD
TEMP
STATOR
WINDING
CLASS
SHUT
-OFF
HEAD
CORD
LENGTH
(FT)
DISCHARGE
(NPT)
LSG202A
2
208/230
60 1 15
53
105˚C 221°F
B
108’
25
1-1/4”
LSG202M
2
208/230
60 1 15 53
105˚C 221°F
B
108’
25
1-1/4”
LSG202M-C*
2
208/230
60 1 15
53
105˚C 221°F
B
108’
35
1-1/4”
LSG203M
2
208/230
60 3 10.6 61
N/A B
108’
25
1-1/4”
LSG204M
2
440/460
60 3 5.3 31
N/A B
108’
25
1-1/4”
LSG205M
2
575 60 3 4.9 31
N/A B
108’
25
1-1/4”
LSGX202A
2
208-230
60 1 15
53
105˚C 221°F
B
185’
25
1-1/4”
LSGX202M
2
208-230
60 1 15 53
105˚C 221°F
B
185’
25
1-1/4”
LSGX202M-C*
2
208-230
60 1 15
53
105˚C 221°F
B
185’
35
1-1/4”
LSGX203M
2
208/230
60 3 10.6 61
N/A B
185’
25
1-1/4”
LSGX204M
2
440/460
60 3 5.3 31
N/A B
185’
25
1-1/4”
LSGX205M
2
575 60 3 4.9 31
N/A B
185’
25
1-1/4”
LSG202M-3E
2
220
50 1 9.7 53
135˚C 275°F
B
85’
35
1-1/4”
LSG204M-3E
2
380 50 3 4.2 31
N/A B
85
35
1-1/4”
LSGX202M-3E
2
220 50 1 12.6 53
135˚C 275°F
B
131
35
1-1/4”
LSGX204M-3E
2
380 50 3 4.3 31
N/A B
131’
35
1-1/4”
*Note: LSG202M-C & LSGX202M-C are for external capacitor applications and require the use of control panels fitted with properly matched capacitors and start relays.
Maximum fluid temperature: 140F (60C)
The grinder pump and the control panel are supplied with their own separate Installation/Operation/Maintenance
manuals. Ensure that you have received these manuals, and that you read and understand them prior to installing this unit. Your familiarity with the grinder pump manual and the control panel manual is critical. This installation manual gives a brief overview of the system, and deals mainly with inspection and installation of the basin, but it does not cover the specifics of the pump operation or the control panel operation. If you have any questions, call customer service at (800) 543-2550.
2 Precautions / Pre-Installation
Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments. These pumps are not to be installed in locations classified as hazardous in the National Electric Code, ANSI/NFPA 70, IEC 60079, or
EN 60079, for countries in accordance with any of these standards.
The electrical connections and wiring for a pump installation should only be made by qualified personnel. This pump is supplied with an earth grounding conductor or a grounding-type attachment plug. To reduce the risk of electric shock,
be certain that the earth grounding conductor is connected only to a properly earth grounded control panel or, if equipped with a grounding-type plug, that it is connected to a properly grounded, grounding-type receptacle.
Do not bypass grounding wires or remove ground prong from attachment plugs. Do not remove cord and strain relief, and do not connect conduit to pump. Do not use an extension cord. This system requires separate, properly fused and grounded branch circuit. Make sure the power source is properly sized for the
voltage and amperage requirements of the system, as noted on the nameplate.