LG ZA P20 Users manual

Page 1
Writer
Subject
ZA-P20 RF TEST MANUAL
Written Date
2011-03-24
Examination
Doc No
Approval
Bang Jun Wan
Doc Class
Test Manual
ZigBee Adaptor(ZA-P20)
Subject: Test Manual
Version
Doc Manager
1.0
KQF-0705-1(0) LG Electronics Inc. A4(210X297)
Page 2
2011-03-24 RF Test Manual
.
1 Operation Method
1. Connect DUT and Power Supply, and Turn on PC.
1) Connect Sample’ s RS232C Port and PC’ s RS232C Port with RS232 serial Cable.
2) DUT’ s Power and GND Line at Power Supply(+12V), and Turn on Switch.
2. DUT and PC serial communication setting
2.1 Hyper Terminal setting
BIT/Sec(B) : 115200 DATA BIT(D) : 8 PARITY(P) : NONE STOP BIT(S) : 1 FLOW CONTROL : NONE
Primary Value Change Value
Ver
1.0
KQF-0705-1(0) LG Electronics Inc. A4(210X297)
Page 3
2011-03-24 RF Test Manual
3. TEST C
OMMAND
3.1 settxpowmode l p – POWER Mode Setting Command
1) Operation Method > Command Setting Mode
2) Setting Mode I p 0 0: Normal-mode, PA-internal
0 1: Normal-mode, PA-External 1 0: Boost-mode, PA-internal 1 1: Boost-mode, PA-External
3) Execution Scene
Ver
1.0
3.2 settxpower p – Output Power Setting Command
1) Operation Method > Command Setting Mode
2) Power Range : +8 ~ -32
3) Execution Scene
KQF-0705-1(0) LG Electronics Inc. A4(210X297)
Page 4
3.3 setchannel
c – Channel setting Command
1) Operation Method > Command Setting Mode (Range: 0x0B ~ 0x1A ) > Channel 0x0B -> Change the 0x0B channel, Channel value must be hexadecimal.
2) Channel Table
Channel 0x0B 2405 MHz Channel 0x0C 2410 MHz Channel 0x0D 2415 MHz Channel 0x0E 2420 MHz Channel 0x0F 2425 MHz Channel 0x10 2430 MHz Channel 0x11 2435 MHz Channel 0x12 2440 MHz Channel 0x13 2445 MHz Channel 0x14 2450 MHz Channel 0x15 2455 MHz Channel 0x16 2460 MHz Channel 0x17 2465 MHz Channel 0x18 2470 MHz Channel 0x19 2475 MHz Channel 0x1A 2480 MHz
3) Execution Scene
2011-03-24 RF Test Manual
Ver
1.0
KQF-0705-1(0) LG Electronics Inc. A4(210X297)
Page 5
2011-03-24 RF Test Manual
3.3 txtone – U
n-modulated Singnal Command
1) Operation Method > Command Setting Mode > t x tone Transmitting Carrier frequency. Press 'e'xit to stop
2) txtone (Unmodulated Singnal) TEST
A. settxpowmode 0 1
B. settxpower 0
C. setchannel 0x0B (see the Channel Table)
D. txtone Command Execution
3) Execution Scene
Ver
1.0
KQF-0705-1(0) LG Electronics Inc. A4(210X297)
Page 6
2011-03-24 RF Test Manual
3.4 txstre
am – Modulated signal’ s Maximum rate transmission mode
1) Operation Method > Command Setting Mode > t x stream 'e'nd...
2) txstream(Modulated Signal) TEST
A. settxpowmode 0 1
B. settxpower 0
C. setchannel 0x0B (see the Channel Table)
D. txstream Command Execution
3) Execution Scene
Ver
1.0
KQF-0705-1(0) LG Electronics Inc. A4(210X297)
Page 7
2011-03-24 RF Test Manual
– rx mode
3.5 rx
1) Operation Method > Command Setting Mode
> rx
Entering RX mode, press c to reset, press e to exit
2) rx TEST
A. settxpowmode 0 1
B. settxpower 0
C. setchannel 0x0B (see the Channel Table)
D. rx Command Execution
3) Execution Scene
Ver
1.0
KQF-0705-1(0) LG Electronics Inc. A4(210X297)
Page 8
2011-03-24 RF Test Manual
4. RF TEST
Method
4.1 un-modulated CW Signal Test
1) Command input for un-modulated signal test(txtone)
A. settxpowmode 0 1
B. settxpower 0
C. setchannel 0x0B (see the Channel Table)
D. txtone Command Execution
2) Execution Scene
Ver
1.0
KQF-0705-1(0) LG Electronics Inc. A4(210X297)
Page 9
4.2 Modu
lated Signal Test
1) Command input for TEST (txstream)
A. settxpowmode 0 1
B. settxpower 0
C. setchannel 0x0B (see the Channel Table)
D. txstream Command Execution
2) Execution Scene
2011-03-24 RF Test Manual
Ver
1.0
KQF-0705-1(0) LG Electronics Inc. A4(210X297)
Page 10
4.3 rx Mode Setting
1) Command input for receive TEST
A. settxpowmode 0 1
B. settxpower 0
C. setchannel 0x0B (see the Channel Table)
D. rx Command execution
2) Execution Scene
2011-03-24 RF Test Manual
Ver
1.0
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modications to this device not explicitly approved by
manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may notcause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolledenvironment. This equipment should be installed and operated with minimum 20 cmbetween the radiator and your body.
KQF-0705-1(0) LG Electronics Inc. A4(210X297)
Loading...