LG WG5005R User Manual [en, es]

www.goldstarappliances.com
GoldStar
MANUAL DEL PROPIETARIO
ROOM AIR CONDITIONER
AIRE ACONDICIONADOR

Models/Modelo WG5005R WG5005

OWNER’S MANUAL
IMPORTANT
before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after
reading it thoroughly.
PRECAUTIONS
> Antes de instalar y poner en marcha su ventilador de
casa, haga el favor de leer cuidadosamente esta instrucción de Usuario.
> Luego de su lectura, guarde este manual para el futuro
usuario para las referencias.
Window-Type Air Conditioner Owner's Manuai

TABLE OF CONTENTS

Safety Precautions.....................3
Before Operation
Introduction
Symbols Used in this Manual
......................
..............................
....
Features .................................8
Electrical Safety
.........................
Temporary Use of an Adapter
................................
11
Temporary Use of an
Extension Cord.....................11
Installation
Window Requirements
Preparation of Chassis Unit instaiiation
Operating Instructions
..............................
Size
....................................
Location Clearance
............................
...........................
.....................
..........
.........
.............
12 12 12 13 13 14 15
16
Location and function of Controis
............................
16 Remote Control Operations ..17 Remote Controller Additional Features
.................
...............
18
19
Air Direction........................19
Drain Pipe...........................19
Removal from Window
.......
19

2/ FORYOUR RECORDS

7
8
8
9
Write the model and serial numbers here:
Model # Serial #
■You con find the numbers on a label on the side of the
product.
Dealer's Name Date Purchased
■ Staple your receipt to this page In the event you need It
to prove date of purchase or for warranty Issues.

P READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You'll find many answers to common problems In the chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for
service at all.

A PRECAUTION

• Contact an Authorized Service Center for repair or
maintenance of this unit. Caii 1-800-243-0000 to locate the nearest ASC.
• The air conditioner is not intended for use by young
children or invalids without supervision.
•Young chiidren should be supervised to ensure that
they do not piay with the air conditioner.
• If the power cord requires replacement, have an
Authorized Servicer instali an exact repiacement part.
• Instaiiation work must be performed in accordance
with the Nationai Eiectric Code by quaiified and authorized personnel only.
Maintenance and Service
Air Filter
..............................
.........
Cleaning the Air Conditioner.20 How to Remove the
Front Grille..........................20
Common Problems and Solutions
Troubleshooting
2 Room Air Conditioner
..............................
....................
20 20
21
22

Safety Precautions

Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
■ Incorrect operation due to Ignoring Instructions will cause harm or damage. The seriousness
Is classified by the following Indications.
■ Because of the weight of the product, it is recommended that you have a helper to assist in
the installation.
^WARNING This symbol Indicates the possibility of death or serious Injury.
Acaution This symbol Indicates the possibility of injury or damage to property only.
I Meanings of symbols used In this manual are as shown below.
N
J
<s>
o

Installation

Be sure not to do.
Be sure to follow the instruction.
=( Awarning y
Always install the expansion panel(s).
* Improper assembly or Installation may cause
incorrect operation, including Injury, fire, and poor performance, electric shock hazards.
Do not use the power cord near flammable Do not disassemble or modify products,
gas or combustibles such as gasoline, benzene, thinner, etc.
It may cause explosion or fire. ' It may cause electric shock and failure.
Do not place the power cord near a heater.
' It may cause fire and electric shock.
Owner’s Manual 3
Safety Precautions

Operation

Plug in the power plug properly.
Otherwise, it will cause electric shock or fire.
Do not modify power cord length.
It will cause electric shock or
fire.
Do not operate or stop the unit by inserting or pulling out the power plug.
It will cause electric shock or
fire.
Use the air conditioner on a single outlet circuit. (See page 7.) Do not share the outlet with other appliances.
' It will cause electric shock or
fire.
m
Do not damage or use an unspecified power cord.
It will cause electric shock or
fire.
Always plug into a grounded outlet.
No grounding may cause
electric shock.
Unplug the unit if strange sounds, odors, or smoke come from it.
Otherwise It will cause fire and electric shock accident.
4 Room Air Conditioner
Do not use the socket if it is loose or damaged.
It may cause fire and electric
shock.
Do not operate with wet hands or in damp environment.
> It may cause electric shock.
Safety Precautions
Close all doors, windows and other outside openings to the room.
The air conditioner must be operated in a enciosed area to be most effective.
If water enters the product, turn off the power switch of the main body of appliance. Contact service center after taking the power plug out from the socket.
* It will cause electric shock or failure of
machine.
Do not operate the air conditioner if
you smell gas.
• It may cause explosion, fire,and burn.
Do not clean the air conditioner with water.
Water may enter the unit and degrage the insulation.lt may cause an electric shock.

Installation

Never touch the metal parts
of the unit when removing the filter.
•They are sharp and may
cause injury.
( Acaution )
Do not block the inlet or outlet.
•It may cause failure of appliance
or performance deteriorate.
Ensure that the outer case is not damaged by age or wear.
• If the outer case is damaged, it must be repaired or replaced immediately. Leaving it damaged could result in the air conditioner falling out of the window, creating a safety hazard.
Owner’s Manual 5
Safety Precautions
Be cautious not to touch
the sharp edges when
installing.
It may cause injury.
Unplug the air conditioner
before cleaning it.
’ Since the fan rotates at high
speed during operation, it may cause injury.
Always insert the filter securely. Clean it every two weeks.
Operation without fiiters will cause failure.
■ Operation
Hold the plug by the hand (not the cable) when taking
it out.
' It may cause electric shock
Do not put a pet or house plant where it will be exposed to direct air flow.
' This could injure the pet or
plant.
Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
• The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
----------
Unplug the air conditioner if it will not be used for a long period.
> It will waste power consumption
in vain and it may cause accident.
Do not use this appliance for special purposes such as cooling pets, foods, precision
machinery, or objects of art.
• It is an air conditioner, not a
precision refrigeration system.
:g)
Do not drink water drained from air conditioner. Do not direct airflow at room occupants only.
’ It is not sanitary and could
cause illness or personal
injury hazard.
If the liquid from the batteries gets onto your skin or clothes, wash It well with clean water. Do not use the remote If the batteries have leaked.
• The chemicals in batteries could cause bums or
other health hazards. S
6 Room Air Conditioner
If you eat the liquid from the batteries, brush your teeth and see doctor.Do not use the remote if the batteries have leaked.
• The chemicals in batteries could cause bums or
other health hazards.
o
Before Operation

L Before Operation

Preparing for operation

1. Plug in the power plug properly.
2. Use a dedicated circuit. Overloading the line could create a fire hazard.
3. Do not use an extension cord. See page 11 for more details.
4. Do not start/stop operation by plugging/unplugging the power cord.
5. If the power cord is damaged and requires replacement, have an Authorized
Servicer install an exact replacement part.

Usage

1. Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used
together with stoves or other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items.
4. The air conditioner is a consumer comfort appliance, not a precision climate
control system.

Cleaning and maintenance

1. Do not touch the metal parts of the unit when removing the filter. Injuries can
occur when handling sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can
destroy the insulation, leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned
off. The fan rotates at a very high speed during operation. There is a
possibility of Injury If the unit's power is accidentally triggered on while cleaning inner parts of the unit.

Service

For repair and maintenance, contact an Authorized Service Center. See the warranty page for details or call (800) 243-0000. Have your model number and serial number available. They should be written on page 2 of this manual.
Owner’s Manual 7
Introduction

^ Introduction

Symbols Used in this Manual

A This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the
A

Features

A
HORIZONTAL
AIR DEFLECTOR
air conditioner.
This symbol indicates special notes.
WARNING: This appliance should be installed in accordance with the
National Electric Code.
KNOB
CABINET
AIR FILTER
CONTROL BOARD
HORIZONTAL AIR DEFLECTOR
Remote controller—
8 Room Air Conditioner
CABINET
ROCKER SWITCHS
FRONT GRILLE
COOL AIR DISCHARGE
AIR FILTER
FRONT GRILLE
COOL AIR DISCHARGE

Ш Electrical Safety

Electrical Data

Electrical Safety
115V-
n
W
Use Wall Receptacle Power Suppiy
Standard 125V, 3-wire grounding receptacie rated 15A, 125V AC
Standard 250V, 3-wire grounding receptacie rated 15A, 250V AC
W
©
Standard 250V, 3-wire grounding receptacle rated 20A, 250V AC
vsy
Use 15 AMP. time delay fuse or 15 AMP. circuit breaker.
Use 20 AMP. time deiay fuse or 20 AMP. circuit breaker.
230V-
Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Use of extension cords
Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated 15A, 125 V.
All wiring should be made in accordance with local electrical codes and regulations.

NOTICE

Aluminum house wiring may pose special problems. Consult a qualified electrician.
ELECTRICAL SAFETY
IMPORTANT GROUNDING INSTRUCTIONS
Air conditioner has a three-prong grounding plug on its power supply cord, which must be plugged into properly grounded three-prong wall receptacle for your protection against possible shock hazard.
230, 208, and 2301208 VOLT UNITS
These units are equipped with a three-prong grounding plug on the power supply cord, which must be plugged into a matching properly grounded three-prong wall receptacle for your protection against possible shock hazard. If such an outlet is not present, one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and ordinances.

NOTICE

DO NOT USE AN EXTENSION CORD on 230,
208, and 230/208 Volt units.
Owners Manual 9

Electrical Safety

Electrical safety
A WARNING: This appliance must be properly grounded.
The power cord of this appliance is equipped with a three-prong grounding plug. To minimize the risk of electric shock, use the plug with a standard three-slot grounding wall power outlet. If the power outlet does not Include a grounding slot,
have a qualified electrician replace the outlet before you use the room air
conditioner.
WARNING: Changing the outlet without making the appropriate wiring changes will create an unsafe condition that could result in fire or
A
electrical shock. Refer all such work to a licensed and qualified electrician.
WARNING: plug.
A
WARNING: Attaching the adapter ground terminal to the wall
receptacle cover screw does not ground the appliance unless the
A
cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
WARNING: If you have any doubt whether the air conditioner is
properly grounded, have the wall receptacle and circuit checked by a
A
qualified electrician.
10 Room Air Conditioner
Do not cut or remove the grounding prong from the power
Electrical Safety

Temporary Use of an Adapter

We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use oniy a UL-iisted adapter, avaiiabie from most iocal hardware stores. Ensure that the iarge slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
A WARNING: Never use the appliance with a broken adapter.

Temporary Use of an Extension Cord

We strongly discourage the use of an extension cord due to potential safety hazards. For temporary situations, use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V.
Owners Manual 11
Installation

B Installation

Have the following tools available for installation:
* Screwdriver (Slotted and Phillips) * Ruler
Knife Pencil
Hammer Level

Window Requirements

Size
This room air conditioner is
designed for installation in standard double-hung windows with actual opening widths from 21" to 35".
The upper and lower window sash
must open sufficiently to allow a clear vertical opening of 12" from the bottom of the upper sash to the window stool.
WARNING: This product is a WINDOW AIR CONDITIONER. As such, a standard single-hung or double-hung window is required for proper installation. Non-window installations, including using sleeves, holes in walls, and other installations are not recommended.
12 Room Air Conditioner
Installation
Location
Install the air conditioner where the
sunlight does not shine directly on the
unit.
Clearance
Proper clearance enhances the cooling efficiency of the unit and prevents heat radiation of the condenser.
* The bottom of the cabinet should be 30" to 60" above the ground. * The outside of the cabinet must extend outward for at least 1/2". * There should be no obstacles such as a fence or wall within 20" from the back
of the cabinet.
* All side louvers of the cabinet must remain exposed to the outside of the
structure.
Owners Manual 13
Installation

Preparation of Chassis

1. Insert the guide panels(Type G) into the guides of the air conditioner (Type H),Fasten the curtains to the unit with screws (Type A).
I: Use a long screwdriver and
installing the screws will be easier.
2. Cut the adhesive-backed seal strip (Type E) to the window width. Remove the backing from the seai strip and attach the seai strip to the underside of the bottom window.
3. Locating unit in window
Open the window and mark center iine on the center of the inner sill.
4. Attach L bracket
4-1. Install the L brackets behind the
inner window sill, with short side of bracket as shown. Use the 2 screws (Type A) provided.
4-2. The bracket helps to hold unit
securely in place. Be sure to place bracket edge flush against back of inner sill.
14 Room Air Conditioner
Inner Sill
Outer Sill Type A ipsWe
Center Line
Outside
L Bracket
Loading...
+ 30 hidden pages