Window Air Conditioner
SVC MANUAL(Exploded View)
MODEL :
CAUTION
Before Servicing the unit, read the safety precautions in Standard SVC manual.
Only for authorized service personnel.
http://biz.lgservice.com
W09TCM-CB60

2 Window Air Conditioner
Cooling Capacity
kW
Btu/h
Heating Capacity
kW
Btu/h
Power Input Cooling/Heating W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER
W/W
Btu/h.W
COP W/W
Power Supply Ø / V / Hz
Power Factor %
Air Flow Rate
Indoor,Max m3/min(cfm)
Outdoor,Max m3/min(cfm)
Moisture Removal l/h
Sound Level Indoor,H/M/L dB(A)+3
Outdoor,Max dB(A)+3
Refrigerant & Charge g(oz)
Type
Model
Compressor
Motor Type
Oil Type
Oil Charge cc
O.L.P Name
Type(In/Out)
Fan Motor Type
Motor Output W
Power Supply Cable No.*mm
2
Dimension W*H*D
mm
inch
Net Weight Indoor kg(lbs)
Tool Code(Chassis)
Temperature Control
Energy Saver Switch
Prefilter(washable/anti-fungus)
Plasma Filter
Steps, Fan/Cool/Heat
Airflow Direction Control(up&down)
Airflow Direction Control(left&right)
Remocon Type
Setting Temperature Cooling
Functions Range Heating
Auto Operation (Micom Control)
Panel Touch Type
Timer
Air Discharge
Air Ventilation
Deice Control(Defrost)
Hot Start
Look
Cabinet Type(Chassis Type)
Special Function
Models
TWC096CBMK1
2.56
8735
-
-
880
3.9
-/-
2.91
9.93
-
1 / 220~240 / 50
94
8.5(142)
0.8
47/-/-
55
R22, 355(12.5)
Rotary(Non Tropical)
PH150X1C-4DVDE3
PSC
SUNISO 4GSD
400
BF785-MH
Propeller
6 POLES
108
3*2.1
660*428*770
25.98*16.85*30.31
56(123.5)
WN
Thermistor
-
O
3/3
-
16°C~30°C
-
-
Micom
-
Side by side
O
O
-
B-Look
-
-
15(250)
WASHABLE
manual
manual
1. Specification
Note:
O
: Applied, - : No relation
*
For circuit breaker rating, please conform to local standards wherever necessary.
❈
Some of functions are slightly different depending upon models.
❈
The specification may be subject to change without notice for purpose of improvement.
MICOM