LG UT30 INSTALLATION MANUAL

P/NO : MFL67855506
INSTALLATION MANUAL
AIR CONDITIONER
www.lg.com
Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
[
Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[
Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si,
Gyeongsangnam-do, KOREA
4-WAY CEILING CASSETTE Original instruction
ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
TIPS FOR SAVING ENERGY
2
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:
• Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air condition­er is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLI­ANCE.
Always comply with the following precautions to avoid danger­ous situations and ensure peak performance of your product
WARNING
!
It can result in serious injury or death when the directions are ignored
CAUTION
!
It can result in minor injury or product damage when the direc­tions are ignored
WARNING
!
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Installation MUST conform with local building codes or, in the absence of local codes, with the Nation Electrical Code NFPA 70/ANSI C1-1003 or current edition and Canadian Electrical Code Part1 CSA C.22.1.
3
ENGLISH
• The information contained in the manual is intended for use by a qualified service technician familiar with safety proce­dures and equipped with the proper tools and test instru­ments.
• Failure to carefully read and follow all instructions in this man­ual can result in equipment malfunction, property damage, personal injury and/or death.
Installation
• Always perform grounding.
- Otherwise, it may cause electrical shock.
• Don’t use a power cord, a plug or a loose socket which is damaged.
- Otherwise, it may cause a fire or electrical shock.
4
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
• For installation of the product, always contact the service cen­ter or a professional installation agency.
- Otherwise, it may cause a fire, electrical shock, explosion or
injury.
• Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.
- If the electrical part cover of the indoor unit and the service
panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.
• Always install an air leakage breaker and a dedicated switch­ing board.
- No installation may cause a fire and electrical shock.
• Do not keep or use flammable gases or combustibles near the air conditioner.
- Otherwise, it may cause a fire or the failure of product.
• Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.
- It may cause injury or an accident.
• Do not disassemble or repair the product randomly.
- It will cause a fire or electrical shock.
• Do not install the product at a place that there is concern of falling down.
- Otherwise, it may result in personal injury.
• Use caution when unpacking and installing.
- Sharp edges may cause injury.
Operation
• Do not share the outlet with other appliances.
- It will cause an electric shock or a fire due to heat genera-
tion.
• Do not use the damaged power cord.
- Otherwise, it may cause a fire or electrical shock.
• Do not modify or extend the power cord randomly.
- Otherwise, it may cause a fire or electrical shock.
• Take care so that the power cord may not be pulled during operation.
IMPORTANT SAFETY INSTRUCTIONS
- Otherwise, it may cause a fire or electrical shock.
• Unplug the unit if strange sounds, smell, or smoke comes from it.
- Otherwise, it may cause electrical shock or a fire.
• Keep the flames away.
- Otherwise, it may cause a fire.
• Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands.
- Otherwise, it may cause a fire or electrical shock.
• Do not use the power cord near the heating tools.
- Otherwise, it may cause a fire and electrical shock.
• Do not open the suction inlet of the indoor/outdoor unit during operation.
- Otherwise, it may electrical shock and failure.
• Do not allow water to run into electrical parts.
- Otherwise, it may cause the failure of machine or electrical
shock.
• Hold the plug by the head when taking it out.
- It may cause electric shock and damage.
5
ENGLISH
• Never touch the metal parts of the unit when removing the fil­ter.
- They are sharp and may cause injury.
• Do not step on the indoor/outdoor unit and do not put any­thing on it.
- It may cause an injury through dropping of the unit or falling
down.
• Do not place a heavy object on the power cord.
- Otherwise, it may cause a fire or electrical shock.
• When the product is submerged into water, always contact the service center.
- Otherwise, it may cause a fire or electrical shock.
• Take care so that children may not step on the outdoor unit.
- Otherwise, children may be seriously injured due to falling
down.
6
ENGLISH
Installation
Operation
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
!
• Install the drain hose to ensure that drain can be securely done.
- Otherwise, it may cause water leakage.
• Install the product so that the noise or hot wind from the out­door unit may not cause any damage to the neighbors.
- Otherwise, it may cause dispute with the neighbors.
• Always inspect gas leakage after the installation and repair of product.
- Otherwise, it may cause the failure of product.
• Keep level parallel in installing the product.
- Otherwise, it may cause vibration or water leakage.
• Avoid excessive cooling and perform ventilation sometimes.
- Otherwise, it may do harm to your health.
• Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
- The appearance of the air conditioner may deteriorate,
change color, or develop surface flaws.
• Do not use an appliance for special purposes such as preserv­ing animals vegetables, precision machine, or art articles.
- Otherwise, it may damage your properties.
• Do not place obstacles around the flow inlet or outlet.
- Otherwise, it may cause the failure of appliance or an acci-
dent.
TABLE OF CONTENTS
TABLE OF CONTENTS
7
ENGLISH
8 INSTALLATION PLACES
9 THE INDOOR UNIT
INSTALLATION
10 Indoor Unit Drain Piping 11 Wiring Connection
13 REMOTE CONTROLLER
INSTALLATION
15 Wired remote controller installation
16 INSTALLATION OF DEC-
ORATIVE PANEL(ACCES­SORY)
18 TEST RUNNING
19 OPTIONAL OPERATION
19 Installer Setting -Test Run Mode 20 Installer Setting - Setting Address of
Central Control
21 Installer Setting -Thermistor 22 Installer Setting -Ceiling Height
Selection
22 Installer Setting-Group Setting 24 Installer Setting-Dry Contact Mode
Setting
25 Installer Setting-Celsius / Fahrenheit
Switching
26 Installer Setting -Optional Function
Setting
27 HOW TO SET E.S.P?
INSTALLATION PLACES
Annexed sheet
Or
Packing corrugated
cardboard on the
bottom
8
ENGLISH
INSTALLATION PLACES
- There should not be any heat source or steam near the unit.
- There should not be any obstacles to prevent the air circulation.
- A place where air circulation in the room will be good.
- A place where drainage can be easily obtained.
- A place where noise prevention is taken into consideration.
- Do not install the unit near the door way.
- Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.
- The indoor unit must keep the maintenance space.
Ceiling
Ceiling Board
500 or more
* Please use an annexed sheet or the corru-
gated cardboard on the bottom of packing as installation sheet.
1000
or more
Ceiling Board
300 or more
500 or more
Above 250
1000 or less
Floor
* When using the bottom sheet, please use it
after separating the installation sheet from packing of the product floor by using a knife etc as a picture below.
Unit : mm
300 or less
THE INDOOR UNIT INSTALLATION
Level gauge
Ceiling
Ceiling board
Unit:mm
Unit:mm
875(Ceiling opening)
787(Hanging bolt)
684
(Hanging bolt)
671
875(Ceiling opening)
840 Unit size
840 Unit size
TQ/TR Series
TP/TN/TM Series
585~660
517
461
517
585~660
523
570
570
319
Use the ventilation fan for smoke-collecting hood with sufficient capacity.
Cooking table
Air conditioner
Take enough distance
THE INDOOR UNIT INSTALLATION
CAUTION
!
• This air-conditioner uses a drain pump.
• Install the unit horizontally using a level gauge.
• During the installation, care should be taken not to damage electric wires.
NOTE
!
Avoid the following installation location.
1 Such places as restaurants and kitchen
where considerable amount of oil steam and flour is generated. These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function. In these cases, take the following actions;
- Make sure that ventilation fan is enough to cover all noxious gases from this place.
- Ensure enough distance from the cook­ing room to install the air conditioner in such a place where it may not suck oily steam.
9
ENGLISH
- Select and mark the position for fixing bolts
- Decide the position for fixing bolts slightly
- Drill the hole for anchor bolt on the wall.
and piping hole.
tilted to the drain direction after considering the direction of drain hose.
2 Avoid installng air conditioner in such
places where cooking oil or iron powder is generated.
3 Avoid places where inflammable gas is
generated.
4 Avoid place where noxious gas is generat-
ed.
5 Avoid places near high frequency genera-
tors.
Loading...
+ 20 hidden pages