LG TW-864AX Service Manual spec

- 1-2 -
SECTION 1. GENERAL
ESD PRECAUTIONS
Electrostatically Sensitive Devices (ESD)
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive Devices (ESD). Examples of typical ESD devices are integrated circuits and some field-effect transistors and semiconductor chip components. The following techniques should be used to help reduce the incidence of component damage caused by static electricity.
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any electrostatic charge on your body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging wrist strap device, which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ESD devices, place the assembly on a conductive
surface such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ESD devices.
4. Use only an anti-static solder removal device. Some solder removal devices not classified as "anti-static" can
generate electrical charges sufficient to damage ESD devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ESD
devices.
6. Do not remove a replacement ESD device from its protective package until immediately before you are ready
to install it. (Most replacement ESD devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable conductive materials).
7. Immediately before removing the protective material from the leads of a replacement ESD device, touch the
protective material to the chassis or circuit assembly into which the device will by installed.
CAUTION : BE SURE NO POWER IS APPLIED TO THE CHASSIS OR CIRCUIT, AND OBSERVE ALL
OTHER SAFETY PRECAUTIONS.
8. Minimize bodily motions when handing unpackaged replacement ESD devices. (Otherwise harmless motion
such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity sufficient to damage an ESD device).
CAUTION. GRAPHIC SYMBOLS
THE LIGHTNING FLASH WITH APROWHEAD SYMBOL. WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE SERVICE PERSONNEL TO THE PRESENCE OF UNINSULATED “DANGEROUS VOLTAGE” THAT MAY BE OF SUFFICIENT MAGNITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK.
THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE IS INTENDED TO ALERT THE SERVICE PERSONNEL TO THE PRESENCE OF IMPORTANT SAFETY INFORMATION IN SERVICE LITERATURE.
- 1-3 -
SPECIFICATIONS
• RADIO SECTION
Frequency range(optional)
MW(AM)
.......................................................................
515~1650kHz OR 515~1750kHz (U.S.A)
FM
..........................................................................................
87.35~108.25MHz OR 64~109MHz
SW1
...........................................................................................................................
2.2~7.3MHz
SW2 ......................................................................................................................... 6.8~22.5MHz
LW ........................................................................................................................... 140~290MHz
Intermediate frequencies
MW(AM)/SW
.....................................................................................................................
455kHz
FM
...................................................................................................................................
10.7MHz
Antenna
MW(AM)
.........................................................................................................
Ferrite bar antenna
FM/SW1/SW2
................................................................................................
Telescopic antenna
• CASSETTE SECTION
Recording system
.................................................................................
4 tracks 2 channel stereo
Frequency response
................................................................................................
125~8,000Hz
S/N ratio
............................................................................................................
40/45dB(rec/play)
• GENERAL
Speaker
...........................................................................................................................
3.2 Ωx 2
Output power
.............................................................................................
(T.H.D10%) 2.5W x 2
AC operation
.........................................................
Refer to the indicated voltage on the back of set
Battery operation
.......................................................
DC 9V,six “D”(R20) batteries(not supplied)
Power consumption
...............................................................................................................
35W
Dimensions(WxHxD)...............................................................................................605 x 249.5 x 211mm
Weight
.................................................................................................................................
5.95kg
NOTE : Design and specifications are subject to change without notice for improvement.