Control (Optional) ................................16
Air Circulation Mode ............................16
Auto Restart Function..........................16
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
■ Staple your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
• Contact the authorized service technician for
repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by
authorized personnel only using only genuine
replacement parts.
following situations ..............................20
2 Room Air Conditioner
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by
the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
■ Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
ENGLISH
Always use a power plug and socket with
a ground terminal.
• There is a risk of electric shock.
For electrical work, contact the dealer, seller,
a qualified electrician, or an Authorized
Service Center. Do not disassemble or repair
the product by yourself.
• There is risk of fire or electric shock.
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
Do not install the product on a defective
installation stand. Be sure that the
installation area does not deteriorate with
age.
• It may cause product to fall.
Do not use a defective or underrated
circuit breaker. Use the correctly rated
breaker and fuse.
• There is risk of fire or electric shock .
Always ground the product as per the
wiring diagram. Do not connect the
ground wire to gas or water pipes
lightening rod or telephone ground wire.
• There is risk of fire or electric shock.
Do not modify or extend the power cable.
If the power cable or cord has scrathes or
skin peeled off or deteriorated then it
must be replaced.
• There is risk of fire or electric shock.
Never install the outdoor unit on a
moving base or a place from where it
can fall down.
• The falling outdoor unit can cause damage or
injury or even death of a person.
Do not use a multi consent. Always use
this appliance on a dedicated cicuit and
breaker.
• Otherwise it can cause electric shock or fire.
Install the panel and the cover of control
box securely.
• There is risk of fire or electric shock due to
dust , water etc.
For installation, removal or reinstall ,
always contact the dealer or an
Authorized Service Center.
• There is risk of fire, electric shock, explosion,
or injury.
When the product is soaked (flooded or
submerged) in water , contact an
Authorized Service Center for repair
before using it again.
• There is risk of fire or eletric shock.
In outdoor unit the step-up capacitor
supplies high voltage electricity to the
electrical components. Be sure to
discharge the capacitor completely
before conducting the repair work.
• An charged capacitor can cause electrical
shock.
When installing the unit, use the
installation kit provided with the product.
• Otherwise the unit may fall and cause severe
injury.
Be sure to use only those parts which
are listed in the svc parts list. Never
attempt to modify the equipment.
• The use of inappropriate parts can cause an
electrical shock, excessive heat generation or
fire.
Owner's Manual 3
Safety Precautions
Indoor/outdoor wiring connections must
be secured tightly and the cable should
be routed properly so that there is no
force pulling the cable from the
connection terminals.
• Improper or loose connections can cause
heat generation or fire.
Be sure to check the refrigerant to the
used. Please read the label on the product.
• Incorrect refrigerant used can prevent the
normal operation of the unit.
Do not place a heater or other heating
appliances near the power cable.
• There is risk of fire and electric shock.
Do not use the product in a tightly closed
space for a long time. Perform ventilation
regularly.
• Oxygen deficiency could occur and hence
harm your health.
Safely dispose off the packing materials.
Like screws, nails, batteries, broken
things etc after installation or svc and
then tear away and thraw away the plastic
packaging bags.
• Children may play with them and cause
injury.
Don't use a power cord, a plug or a loose
socket which is damaged.
• Otherwise it may cause a fire or electrical
shock.
Do not allow water to run into electric
parts. Install the unit away from water
sources.
• There is risk of fire, failure of the product, or
electric shock.
Do not open the front grille of the product
during operation. (Do not touch the
electrostatic filter, if the unit is so equipped.)
• There is risk of physical injury, electric shock,
or product failure.
Make sure to check that the power cable
plug is not dirty, loose or broken and
then only insert the plug completely.
• Dirty, loose or broken power plug can
cause electric shock or fire.
Do not touch , operate, or repair the
product with wet hands. Hold the plug by
hand when taking out
• There is risk of electric shock or fire.
Do not store or use or even allow
flammable gas or combustibles near the
product.
• There is risk of fire.
If strange sounds, smell or smoke comes
from product.Immediately turn the breaker
off or disconnect the power supply cable.
• There is risk of electric shock or fire.
Ventilate the product room from time to
time when operating it together with a
stove, or heating element etc.
• Oxygen deficiency can occur and hence harm
your health.
Take care to ensure that nobody
especially kids could step on or fall onto
the outdoor unit.
• This could result in personal injury and
product damage.
Do not plug or unplug the power supply plug to turn the unit
ON/OFF .
• There is risk of fire or electric shock.
Two or more people must lift and
transport the product.
• Avoid personal injury.
Turn the main power off and unplug the
unit when cleaning or repairing the
product.
• There is risk of electric shock.
Take care to ensure that power cable
could not be pulled out or damaged
during operation.
• There is risk of fire or electric shock.
When flammable gas leaks, turn off the gas and open a window
for ventilation before turn the product on.
• Do not use the telephone or turn switches on or off. There is risk of
explosion or fire.
Do not install the product where it will be
exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product.
When the product is not to be used for a
long time, disconnect the power supply
plug or turn off the breaker.
• There is risk of product damage or failure, or
unintended operation.
Do not place ANYTHING on the power
cable.
• There is risk of fire or electric shock.
Install the drain hose to ensure that the
condensed water is drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the
product.
• To avoid vibration or noise.
4 Room Air Conditioner
Do not install the product where the noise
or hot air from the outdoor unit could
damage or disturb the neighborhoods.
• It may cause a problem for your neighbors
and hence dispute.
Always check for gas (refrigerant)
leakage after installation or repair of
product.
• Low refrigerant levels may cause failure of
product.
Safety Precautions
Do not use the product for special purposes,
such as preserving foods, works of art, etc. It
is a consumer air conditioner, not a precision
refrigeration system.
• There is risk of damage or loss of property.
Do not touch the metal parts of the
product when removing the air filter.
• There is risk of personal injury.
Do not insert hands or other objects
through the air inlet or outlet while the
product is operating.
• There are sharp and moving parts that could
cause personal injury.
Do not tilt the unit when removing or
uninstalling it.
• The condensed water inside can spill .
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Do not step on or put anyting on the
product. (outdoor units)
• There is risk of personal injury and failure of
product.
Be cautious when unpacking and
installing the product.
• Sharp edges could cause injury.
Do not mix air or gas other than the
specified refrigerant used in the system .
• If air enters the refrigerant system, an
excessively high pressure results, causing
equipment damage or injury.
Use a soft cloth to clean. Do not use
harsh detergents, solvents or splashing
water etc .
• There is risk of fire, electric shock, or damage
to the plastic parts of the product.
Always insert the filter securely after
cleaning. Clean the filter every two weeks
or more often if necessary.
• A dirty filter reduces the efficiency.
If the refrigerant gas leaks during the
repair, do not touch the leakaing
refrigerant gas.
• The refrigernat gas can cause frostbite (cold
burn)
If the refrigerant gas leaks during the
installation, ventilate the area immediately.
• Otherwise it can be harmfull for your health.
ENGLISH
Dismantling the unit, treatment of the
refrigerant oil and eventual parts should
be done in accordance with local and
national standards.
If the liquid from the batteries gets onto
your skin or clothes, wash it well with
clean water. Do not use the remote if the
batteries have leaked.
• The chemicals in batteries could cause burns
or other health hazards.
Do not drink the water drained from the product.
• It is not sanitary and could cause serious health issues.
Replace the all batteries in the remote
control with new ones of the same type.
Do not mix old and new batteries or
different types of batteries.
• There is risk of fire or product failure.
Do not let the air conditioner run for a
long time when the humidity is very high
and a door or a window is left open.
• Moisture may condense and wet or damage
furniture.
Use a firm stool or ladder when cleaning, maintaining or
repairing the product at an height.
• Be careful and avoid personal injury.
Do not recharge or disassemble the
batteries. Do not dispose off batteries in
a fire.
• They may burn or explode.
Do not expose your skin or kids or
plants to the cool or hot air draft.
• This could harm to your health.
Owner's Manual 5
Electrical Safety
Electrical Safety
• This appliance must be properly grounded.
To minimize the risk of electric shock, you must alway plug into a grounded oulet.
• Do not cut or remove the grounding prong from the power plug.
• Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance
unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the
house wiring.
• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and
circuit checked by a qualified electrician.
Temporary Use of an Adapter
We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections,
use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in the
adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground
terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
• Never use the appliance with a broken adapter.
Temporary Use of an Extension Cord
We strongly discourage the use of an extension cord due to potential safety hazards. For temporary
situations, use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V.
This appliance should be installed in accordance with national wiring regulations. This guide acts as a
guide to help to explain product features.
Symbols used in this Manual
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the
air conditioner.
NOTE
6 Room Air Conditioner
This symbol indicates special notes.
Product Introduction
Product Introduction
Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your
indoor unit type.
Indoor Units
Standard Split Type
Display panel LED indicators
Air inlet
Grille tab
Plasma filter (Optional)
Front grille
ON/OFF button
Air filter
ENGLISH
Air outlet
Art Cool Type
Display panel LED indicators
Front panel
Signal receiver
ON/OFF button
Air discharge
Art Cool Type Wide
Display panel LED indicators
Louvers
(Vertical blades)
(Horizontal blade)
Flap
Signal
receiver
Plasma filter
Air filter
Power cord
Plasma filter
Air inlet
Front panel
Power cord
ON/OFF button
Air discharge
Air filter
Signal receiver
Owner's Manual 7
Product Introduction
Art Cool Deluxe(Type 1)
Display panel LED indicators
Air inlet
Plasma filter
Air filter
Air discharge
Front panel
Signal receiver
Power cord
ON/OFF button
Operation Indication Lamps
On/Off
Sleep mode
Energy-Saving
Cooling Mode
Plasma
: Lights up during the system operation, error code and auto restart setting.
: Lights up during sleep mode auto operation.(non-Inverter Model)
: Lights up during Energy-Saving Cooling Mode Operation(Inverter Model only)
: The function illustrates its dynamic mode by using a multiple lighting system.
Art Cool Deluxe(Type 2)
Display panel LCD indicators
Air discharge
Front panel
Signal receiver
Air inlet
Air filter
Plasma filter
Power cord
ON/OFF button
Timer
: Lights up during timer operation.(non-Inverter Model)
Lights up during timer operation or sleep mode auto operation (Inverter Model only)
*hot start operation (Heat pump model only)
OUT
DOOR
Defrost mode
Outdoor unit
operation
: Lights up during defrost mode or
: Lights up during outdoor unit operation. (Cooling model only)
Power Display : Indicates the setting temperature and operation mode.
Operation
mode
Shape of
display
Cooling, heating,
Dehumidification
Mode
Setting
temperature
StandardToo hotHotColdToo cold
Auto operation mode
Comfortable
Jet
Cool/Heat
Energy-saving
cooling mode
Test
operation
Auto
clean
* Hot start operation: Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out
from unit.
* In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat
exchanger coils to maintain the efficiency.
Outdoor Unit
Air intake vents
Connecting
wires
Air outlet vents
Base plate
8 Room Air Conditioner
Refrigerant pipes
Drain hose
Operating Instructions
Operating Instructions
How to insert the Batteries
1. Remove the battery cover by pulling it according to the arrow
direction.
2. Insert new batteries making sure that the (+) and (-) of battery are
installed correctly.
3. Reattach the cover by sliding it back into position.
NOTE
1. Always use/replace both batteries of same type.
2. If the system is not to be used for a long time, remove the
batteries to save their working life.
3. If the display screen of remote controller starts, fading replace
both of the batteries.
Wireless Remote Controller Maintenance
1. Choose a suitable place where its safe & easy
to reach.
2. Fix the holder to wall etc with the supplied
screws firmly.
3. Slide the remote controller inside the holder.
ENGLISH
NOTE
1. Remote controller should never be exposed to
direct sunlight.
2. Signal transmitter & receiver should always be
clean for proper communication. Use a soft
cloth to clean them.
3. In case some other appliances also get
operated with remote control, change their
position or consult your serviceman.
Operating Method
1. The signal receiver is inside the unit.
2.
Aim the remote controller towards the unit to operate it.
There should not be any blockage in between.
Owner's Manual 9
Operating Instructions
Wireless Remote Controller
The controls will look like the following.
1. START/STOP BUTTON
Used to turn off/on the unit.
Signal transmitter
2. OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
3. ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
4. INDOOR FAN SPEED SELECTOR BUTTON
Used to select fan speed in four steps
low, medium, high and CHAOS.
5. JET COOL BUTTON
Used to start or stop the speed cooling.
(It operates fan in super high speed in cooling mode)
5
1
6
3
6. CHAOS SWING BUTTON
Used to stop or start louver movement and set the
desired up/down airflow direction.
7. ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping
4
2
7
11
8
13
15
ON
OFF
CANCEL
SET
AUTO CLEAN
10
9
12
17
19
18
14
16
operation.
8. TIME SETTING BUTTONS
Used to adjust the time.
9. TIMER SET/CANCEL BUTTON
Used to set and to cancel the timer operation.
10. SLEEP MODE AUTO BUTTON
Used to set sleep mode auto operation.
11. AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or
heating.
ENERGY-SAVING COOLING MODE BUTTON
(OPTIONAL) For inverter type models
Flip-up door
(opened)
12. ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
13. PLASMA BUTTON(OPTIONAL)
Operation Mode
Used to start or stop the plasma-purification
function.
Cooling Operation
14. HORIZONTAL AIRFLOW DIRECTION CONTROL
BUTTON (OPTIONAL)
Auto Operation or Auto Changeover
Used to set the desired horizontal airflow direction.
15. RESET BUTTON
Used prior to resetting time.
Healthy Dehumidification Operation
16. 2nd F BUTTON
Used prior to using modes printed in blue at the
Heating Operation
•
Cooling Model(), Heat Pump Model()
NOTE
To use the functions printed in blue at the bottom of the buttons press 2
button. Pressing the 2
press the 2nd F button again else it will automatically cancel if remains idle after 10 seconds.
nd
F button activates the blue printed function of the respective button. To cancel the function
bottom of buttons.
17. AUTO CLEAN BUTTON(OPTIONAL)
Used to set auto clean mode.
In some models this button has a 2nd function of LED
luminosity control.
18. HEATER BUTTON(OPTIONAL)
(Not available in all models)
19. LCD LUMINOSITY BUTTON(OPTIONAL)
Used to adjust LCD luminosity.
nd
F button first and then the required function
10 Room Air Conditioner
ON
Operation Mode
1
Operating Instructions
Press the START/STOP BUTTON to
turn the unit on.
The unit will respond with a beep.
ENGLISH
3
1
2
3
Open the door of the remote controller and press the
operation mode button. Each time the button is pressed, the
operation mode is shifted in the direction of the arrow.
4
2
Cooling
Auto Operation (Cooling Only Model)
Auto Changeover (Heat Pump Model)
For cooling or heating operation set the desired indoor
temperature by pressing the ROOM TEMPERATURE
SETTING BUTTONS.
For cooling the temperature can be set within 18°C~30°C and
for heating the temperature range is 16°C~30°C.
Auto
Changeover
Healthy
Dehumidification
(Heat pump model only)
To raise the temperature
To lower the temperature
Heating
Set the fan speed with the remote controller. You can select the fan speed in four steps-low,
4
Natural wind by the CHAOS logic
❏
medium, high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON.
Each time the button is pressed, the fan speed mode is shifted.
Fan speed is on low.Fan speed is on medium. Fan speed is on high.CHAOS Air
For fresher feeling, press the INDOOR FAN SPEED SELECTOR BUTTON selector and set to CHAOS mode.
In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
Owner's Manual 11
Operating Instructions
Healthy Dehumidification Operation
During Healthy Dehumidification Operation
❏ If you select the dehumidification mode on the OPERATION MODE
SELECTION BUTTON, the product starts to run the dehumidification
function. It automatically sets the room temperature and airflow volume to
the best condition for dehumidification, based on the sensed current room
Healthy
Dehumidification
temperature.
In this case, however, the setting temperature is not displayed on the remote
controller and you are not able to control the room temperature either.
❏ During the healthy dehumidification function, the airflow volume is
automatically set according to the optimization algorithm responding to the
current room temperature status, so that the room condition is kept healthy
and comfortable even in the very humid season.
To run the healthy dehumidification mode follow steps 1, and 2 and 4
(See operation mode)
Auto Operation (Cooling Only Model)
In this operation mode the actual setting temperature and the fan speed
are automatically set by the electronic control logic based on the current
room temperature. If you feel hot or cold press the temperature setting
buttons respectively for more cooling or heating effect.
NOTE : You cannot set the actual setting temperature and the indoor fan
Auto
To run the auto operation follow steps 1, and 2. (See operation mode)
speed in this operation mode. But you can use the Chaos swing
in this operation.
If the system is not operating as desired, switch manually to
another mode.
Auto Changeover Operation (Heat Pump Model)
Auto
Changeover
12 Room Air Conditioner
Auto operation basically is heating or cooling function of the air
conditioner.
But during this operation the controller changes the operation mode
automatically to keep the temperature within ±2°C with respect to the
setting temperature.
To run this operation follow steps 1, 2, 3, and 4. (See operation mode)
Operating Instructions
Jet Cool/Heat Operation
Jet cool function can be used to cool the room quickly in hot summer. When this
function is turned on, the air conditioner runs in cooling operation mode with super
high fan speed and 18°C setting temperature for 30 minutes for fast and effective
cooling.
Similarly, jet heat function (available only in some models) warms up the room quickly
by operating at super high fan speed and 30°C setting temperature for 60 minutes.
You can activate this operation by pressing the JET COOL BUTTON.
To change from jet cool mode to high fan speed cooling mode, press the JET COOL BUTTON or
INIDOOR FAN SPEED SELECTOR BUTTON or the ROOM TERPERATURE SETTING BUTTON again.
NOTE
• Jet cool function cannot be activated during heating or auto changeover operations.
• In case of Inverter, Art Cool and Art Cool Wide(non-Deluxe) model, you can use jet heat function by
pressing JET COOL BUTTON for heating operation.
• Art Cool and Art Cool Wide models close the side discharges during jet cool/heat operation, for strong
cooling and heating.
ENGLISH
NEO PLASMA Purification Operation (Optional)
Plasma filter is a technology developed by LG to get rid of microscopic
contaminants in the intake air by generating a plasma of high charge electrons.
This plasma kills and destroys the contaminants completely to provide clean and
hygienic air.
Plasma purification can be started by pressing the PLASMA BUTTON on the remote controller.
Repressing it will deactivate the operation.
NOTE
This feature can be used in any operation mode and any fan speed can be used while
plasma filter is functioning.
Auto Clean (Optional)
❏ During auto clean function, moistures left in indoor units after cooling operation or healthy dehumidification
operation can be removed.
AUTO CLEAN
NOTE
❏ During auto clean function, only START/STOP BUTTON, PLASMA BUTTON and AUTO CLEAN BUTTON
can be used.
1. Press the AUTO CLEAN BUTTON to activate this function.
2. Now whenever the unit is turned off, the indoor fan is still running for about 30
minutes internally without cooling or dehumidification operation. Also the louver is
closed.
3. This dries up any remains of moisture & cleans the unit internally.
4. If you press AUTO CLEAN BUTTON again during operation, this function is
cancelled.
Owner's Manual 13
Loading...
+ 29 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.