LG PQWRCDF0, 457938 User Manual

OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating your set and retain it for future reference.
P/NO : 3828A20580F
www.lge.com
TYPE : Wireless Remote Controller
ENGLISH
ITALIANO
ESPAÑOL FRANCAIS
DEUTSCH
2 Wireless Remote Controller
Wireless Remote Controller Ownerʼs & Installation Manual
TABLE OF CONTENTS
Safety Precaution................................................................3~4
Part Description ..................................................................5~6
Operating Instruction..............................................................7
Installation Instruction............................................................8
- Setting Address of Central Control...........................................8
- Checking Address of Central Control.......................................8
- How to Enter Installer Setting Mode.........................................9
- Installer Setting Code Table ...................................................10
Owner's Instruction...............................................................11
- Cooling Mode .......................................................................11
- Auto Operation Mode .............................................................12
- Auto Changeover Mode .........................................................13
- Dehumidification Mode...........................................................15
- Heating Mode.........................................................................16
- Fan Mode ...............................................................................17
Temperature Setting / Room Temperature Checking.........18
Airflow Setting (Optional).....................................................19
Sub Function .........................................................................20
- Plasma Purification (Optional)................................................20
- Auto Clean (Optional).............................................................20
- Smart Clean (Optional) ..........................................................21
- LCD Luminosity Control (Optional) ........................................22
- Celsius / Fahrenheit Switching (Optional) ..............................22
- Electric heater (Optional) .......................................................22
- Individual vane angle control (Optional).................................23
Timer.......................................................................................24
- Setting the Current Time ........................................................24
- Timer Setting..........................................................................24
- To Cancel the Timer Setting ...................................................24
Safety Precautions
Ownerʼs & Installation Manual 3
ENGLISH
Installation
Operation
Safety Precautions
• The installation requires expert skills, and it should be installed by the service center or other shops specialized in the installation and recognized by our company.
• For all the problems arising after installation by someone who has no relevant qualifications, our company will not provide free service.
• The following safety cautions are provided to prevent unexpected dangers or losses.
: If the user does not follow the mandatory items, it may result in serious injury or death.
: If the user does not follow the mandatory items, it may cause personal injury or property
damage.
: Warning and Caution are to call the userʼs attention to the possible danger. Read and follow
them carefully in order to prevent a safety accident.
: Warning and Caution are indicated in this guide and the product itself to help protect the users
from danger.
WARNING
CAUTION
WARNING
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire. They may burn or explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other health hazards.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries. There is risk of fire or explosion
Do not disassemble, repair, or modify the product at your discretion in order to prevent fire or an electric shock.
Safety Precautions
4 Wireless Remote Controller
Push the button at one time. There will be no operation if you Several buttons at one time.
Do not drop or throw the remote Controller. Do not give any strong impact and Put your foot it.
Do not use this at the moisture and Humidity places.
Do not use this at heating and Firing conditions.
Do not place the remote controller in a location exposed to direct sunlight
Aim at the signal receptor on the wiress remote controller so as to operate
Only'
One
Signal receptor
Signal receptor
7m
Signal receptor
The remote control signal can be received at a distance of up to about 7m
Be sure that there are no obstructions between the remote controller and the signal receptor
Block a strong light over the signal receptor with a curtain or etc. so as to prevent the abnormal operation. (ex:electronic quick start, ELBA, inverter type fluorescent lamp)
CAUTION
Part Description
Ownerʼs & Installation Manual 5
Part Description
Accessory
ENGLISH
Holder(1EA) Fixing Screw (2EA) Owner's / Installation
Manual
AAA(1.5V)
Batteries(2EA)
LCD Screen
Slide door(Closed)
Wireless Remote Controller
Part Description
6 Wireless Remote Controller
Wireless Remote Controller
PLASMA Button (OPTIONAL)
Used to start or stop the plasma-purification function.
JET COOL Button
Speed cooling operates super high fan speed.
OPERATION MODE SELECTION Button
Used to select the operation mode.
FUNCTION SETTING Button
Used to set or clear Auto Clean, Smart Clean, Electric heater or Individual vane angle control
LCD LUMINOSITY Button (OPTIONAL)
Used to adjust LCD luminosity
SMART CLEAN Button (OPTIONAL)
Used to start or stop Smart Clean.
CLEAR ALL Button
Used to clear all timer.
ROOM TEMPERATURE SETTING Button
Used to select the room temperature.
ON/OFF Button
Used to turn on/off the unit.
INDOOR FAN SPEED SELECTION Button
Used to select fan speed in four steps low, medium, high and chaos.
UP/DOWN AIRFLOW Button
Used to stop or start louver movement and set the desired up/down airflow direction.
LEFT/RIGHT AIRFLOW Button (OPTIONAL)
Used to set the desired left/right(horizontal) airflow direction.
TIMER AND TIME SETTING Button
Used to set the time of starting or stopping and sleeping operation.
ROOM TEMPERATURE CHECKING Button
Used to check the room temperature.
°C/°F SWITCH Button
Used to switch temperature reading from Celsius to Fahrenheit.
RESET Button
Used to reset the remote controller.
8
1
2
3
4
5 6
7
Operation Mode
Cooling Mode
Auto Mode or Auto Changeover
Dehumidification mode
Heating Mode
Fan Mode
Cooling Model( ), Heat Pump Model( )
9
10
11
12
13 14
15
16
Operating Instruction
Ownerʼs & Installation Manual 7
ENGLISH
Operating Instruction
1. Choose a suitable place where its safe & easy
to reach.
2. Fix the holder to wall etc with the supplied
screws firmly.
3. Slide the remote controller inside the holder.
1. Remote controller should never be exposed to direct sunlight.
2. Signal transmitter & receiver should always be clean for proper communication. Use a soft cloth to clean them.
3. In case some other appliances also get operated with remote control, change their position or consult your serviceman.
1. The signal receiver is inside the unit.
2.
Aim the remote controller towards the unit to operate it. There should not be any blockage in between.
NOTE
How to insert the Batteries
Wireless Remote Controller Maintenance
1. Remove the battery cover by pulling it according to the arrow direction.
2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
3. Reattach the cover by sliding it back into position.
1. Always use/replace both batteries of same type.
2. If the system is not to be used for a long time, remove the batteries to save their working life.
3. If the display screen of remote controller starts, fading replace both of the batteries.
NOTE
Operating Method
Installation Instruction
8 Wireless Remote Controller
Installation Instructions
Installer Setting - Setting Address of Central Control
Installer Setting - Checking Address of Central Control
With the MODE button pressed, press the RESET button.
1
With the PLASMA button pressed, press the RESET button.
1
Press the ON/OFF button toward the indoor unit 1 time, and the indoor unit will display the set address in the display window.
- The address display time and method can differ by the indoor unit type.
2
Reset the remote controller to use the general operation mode.
3
By using the TEMPERATURE SETTING button, set the indoor unit address.
- Setting range : 00 ~ FF
2
After setting the address, press the ON/OFF button toward the indoor unit 1 time.
3
The indoor unit will display the set address to complete the address setting.
- The address display time and method can differ by the indoor uint type.
Reset the remote controller to use the general operation mode.
4 5
Group No.
Indoor Unit No.
Installation Instruction
Ownerʼs & Installation Manual 9
ENGLISH
Installer Setting -How to enter installer setting mode
With the FAN SPEED button pressed, press the RESET button.
1
By using the TEMPERATURE SETTING button, set function code and setting value. (Please refer the Installer Setting Code Table.)
2
Installer setting mode is to set the detail function of the remote controller. If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage. This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated person should be responsible for the results. In this case, free service cannot be provided.
CAUTION
Press the ON/OFF button toward the indoor unit 1 time.
3
Reset the remote controller to use the general operation mode.
4
Refer to the Installer Setting Code Table on the next page.
Function Code
Setting Code
Installation Instruction
10 Wireless Remote Controller
Installer Setting - Installer Setting Code Table
No. Function Function Code Setting Value Remote Controller LCD
0 Mode Override
0 : Set to Master
1 : Set to Slave
1 : Standard
1
2 : Low
3 : High
4 : Super High
0 : Set to Master
Group Control 1 : Set to Slave
2 : Check Master/Slave
3 :
Set to Auxiliary heater
Auxiliary heater 4 :
Cancel Auxiliary heater
5 :
Check Auxiliary heater Installation
Installer Setting Code Table
0
1
2
Ceiling Height
Selection
Mode Override
This Function is only for Non-Auto Changeover H/P model.
Ceiling Height Selection
Indoor unit connected to wired remote controller operate as wired remote controller setting.
Group Control
This function is only for group control. Please donʼt set this function in case of non-group control. After setting Group Control of the product, turn off the power then turn it back on after 1 minute.
Auxiliary heater
This function is only applied to models with Auxiliary Heater function being activated.
2
2
22
Ownerʼs & Installation Manual 11
Owner's Instruction
ENGLISH
Cooling Mode - Standard Operation
Press the ON/OFF button. The unit will respond with beep sound.
1
Press MODE button to select Cooling Mode.
2
To lower the temperature
To raise the temperature
Set the desired temperature by pressing TEMP button. Press ROOM TEMPERATURE CHECKING button to check the room temperature. When setting the desired temperature is higher than room temperature, cooling wind isnʼt blow out.
Setting Temp. Range : 18~30°C(64~86°F)
3
Cooling Mode - Power Cooling
Press the ON/OFF button. The unit will respond with beep sound.
1
Press MODE button to select Cooling Mode.
2
Press the JET COOL button. The unit will operate in super high fan speed in cooling mode. Wall mounted models operate power cooling mode for
30 minutes.
3
To cancel the Power cooling Mode press the Jet Cool button or the fan button or the room temperature setting button again and the unit will operate in high fan speed in cooling mode.
4
or or
Owner's Instruction
12 Wireless Remote Controller
Owner's Instruction
Auto Operation Mode
Press the ON/OFF button. The unit will respond with beep sound.
1
Press MODE button to select Auto Operation Mode.
2
During Auto Operation Mode
• If the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating to cooling, then you must set the mode and the desired temperature again.
Set the desired temperature.
<For Cooling Model>
The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you feel hot or cold, press TEMPERATURE SETTING buttons for more cooling or heating effect. You cannot switch the indoor fan speed. It has already been set by the Auto Operation Mode rule.
You can set desired temperature and indoor fan speed. Setting Temp. Range : 18~30°C(64~86°F)
<For Heating Model>
3
Code Feel 2 Cold 1 Slightly cool 0 Neutral
-1 Slightly warm
-2 Warm
Please select the code depend on your feeling.
To raise the temperature
To lower the temperature
Ownerʼs & Installation Manual 13
ENGLISH
Owner's Instruction
Auto Changeover Mode
Press the ON/OFF button. The unit will respond with beep sound.
1
Press MODE button to select Auto Changeover Mode.
2
Set the desired room temperature. Setting Temp. Range in Auto Changeover Mode : 18~30°C
(64~86°F)
3
You can select the fan speed in four stepss-low, medium, high and chaos. Each time the button is pressed, the fan speed mode is shifted.
4
This Function is only available on some products.
During Auto changeover Mode
The air conditioner changes the operation mode automatically to keep indoor temperature. When room temperature vary over ±2°C(4°F) with respect to setting temperature, air conditioner keeps the room temperature within ±2°C(4°F) with respect to setting temperature by auto changeover mode.
To raise the temperature
To lower the temperature
14 Wireless Remote Controller
Owner's Instruction
Auto Changeover Mode - Setting the Mode Change Temperature
This Function is to set the operating mode of the Auto Changeover Mode.
The Mode Change Temperature is the difference of temperature when from cooling mode to heating mode or from heating mode to cooling mode.
Ex) When setting temperature is 25°C(76°F) and room temperature is 20°C(68°F), then operating mode is
heating. If you set the mode change temperature to 2°C(4°F), when the room temperature up to 27°C(25°C + 2°C)(80°F(76°F + 4°F)), the unit start cooling operation.
In Auto Changeover Mode, Press the ROOM TEMPERATURE CHECKING button for 3 seconds. The mode change temperature set before will be displayed.
1
Press the TEMPERATURE SETTING button to set desired Mode Change Temperature. (Default value is 2°C(4°F).)
2
Press for 3 seconds.
Mode Change Temp. Range
: 1~7°C(2~14°F)
To raise the temperature
To lower the temperature
Ownerʼs & Installation Manual 15
ENGLISH
Owner's Instruction
Dehumidification Mode
Press the ON/OFF button. The unit will respond with beep sound.
1
Press MODE button to select Dehumidification Mode.
2
Set the fan speed. You can select the fan speed in four steps - low, medium, high, or chaos. Each time the button is pressed, the fan speed mode is shifted.
3
During Dehumidification Mode
• If you select the dehumidification mode on the operation selection button, the indoor unit starts to run the dehumidification function, automatically setting the room temp. and air volume to the best condition for dehumidification based on the sensed room temp. In this case, the setting temp. is not displayed in the Remote Controller and you are not able to control the room temp. either.
• During the healthy dehumidification function, the air volume is automatically set according to the algorithm responding to the current room temp. and makes the room condition healthy and comfortable even in the high humidity season.
16 Wireless Remote Controller
Owner's Instruction
Set the desired temperature by pressing TEMP button. Press ROOM TEMPERATURE CHECKING button to check the room temperature. When setting the desired temperature is lower than room temperature, heating wind isnʼt blow out.
3
Set the fan speed again. You can select the fan speed in four steps–low, medium, high, or chaos. Each time the button is pressed, the fan speed mode is shifted.
4
Press the ON/OFF button. The unit will respond with beep sound.
1
Press MODE button to select Heating Mode.
2
Heating Mode
This Function is only for H/P model.
Setting Temp. Range in
Heating Mode : 16~30°C (60°F~86°F)
To raise the temperature
To lower the temperature
Ownerʼs & Installation Manual 17
ENGLISH
Owner's Instruction
Fan Mode
Set the fan speed again. You can select the fan speed in four steps–low, medium, high, or chaos. Each time the button is pressed, the fan speed mode is shifted.
3
Press the ON/OFF button. The unit will respond with beep sound.
1
Press MODE button to select Fan Mode.
2
Natural Wind by the chaos Logic
• For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to chaos mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the chaos logic.
During Fan Mode
• The outdoor compressor doesn't work. Have a function to circulate the indoor as it sends out the air that doesn't have much temperature difference with indoor.
18 Wireless Remote Controller
Temperature Setting/Room Temperature checking
We can simply adjust the desired temperature
• Press the buttons to adjust the desired temperature
: Increase 1˚C or 2˚F per one time pressing
: Decrease 1˚C or 2˚F per one time pressing
Room temp: Indicate the current room temperature Set temp: Indicate the temperature that user want to set
<Cooling Mode>
The cooling mode doesn't work if desired temperature is higher than room temperature Please lower the desired temperature
<Heating Mode> The heating mode doesn't work if desired temperature is lower than room temperature Please increase the desired temperature
Whenever press button, the room temperature will be displayed within 5 seconds. After 5 seconds, it turns to display the desired temperature. Because of location of remote controller, the real room temperature and the this displayed value can be different.
Temperature Setting/Room Temperature checking
Ownerʼs & Installation Manual 19
ENGLISH
Airflow Setting
The up/down airflow (Vertical Airflow) can be adjusted by using the remote controller.
1. Press the ON/OFF button to start the unit.
2. Press UP/DOWN AIRFLOW button and the louvers will swing up and down. Press the UP/DOWN AIRFLOW button again to set the vertical louver at the desired airflow direction.
• If you press the UP/DOWN AIRFLOW button, the horizontal airflow direction is changed automatically based on the Auto Swing algorithm to distribute the air in the room evenly and at the same time to make the human body feel more comfortable, as if enjoying a natural breeze.
• Always use the remote controller to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand, could damage the air conditioner.
• When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system.
The left/right(horizontal) airflow can be adjusted by using the remote control.
1. Press the ON/OFF button to start the unit.
2. Press the LEFT/RIGHT AIRFLOW button and the louvers will swing left and right. Press the Horizontal Airflow Direction Control Button again to set the horizontal louver at the desired airflow direction.
Up/Down and Left/Right Airflow function isnʼt shown on display of remote controller.
NOTE
Up/Down Airflow Direction Control (Optional)
Left/Right Airflow Direction Control (Optional)
Airflow Setting
Sub function
20 Wireless Remote Controller
Plasma Purification(Optional)
Press the ON/OFF button. The unit will respond with beep sound.
1
Press the PLASMA button. Plasma Purification will start when the button is pressed and stop when the button is pressed again.
2
PLASMA Purification only
If you press the PLASMA button, Plasma Purification operates.
• Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air generating a plasma of high charge electrons. This plasma kills and destroys the contaminants completely to provide clean and hygienic air.
• This function can be used in any operation mode and any fan speed can be used while plasma filter is functioning.
Sub function
Auto Clean (Optional)
This function operate when the unit is turned off.
Press the FUNCTION SETTING button 1 time. Auto Clean symbol will blink.
1
Press the SET/CLEAR button to reserve or cancel the Auto Clean function.
If the Auto Clean function is reserved, whenever the unit is turned off, the indoor fan is still running for about 30 minutes internally without cooling or dehumidification operation. Also the louver is closed. This dries up any remains of moisture & cleans the unit internally.
2
Sub function
Ownerʼs & Installation Manual 21
ENGLISH
Smart Clean (Optional)
The Smart Clean function can be used by setting to manual or automatic.
Auto Smart Clean operation
If the accumulated operation time of the product exceeds 30 hours, the Smart Clean automatically starts when the unit is turned off.
1. Press the FUNCTION SETTING button 2 times. Smart Clean symbol will blink.
2. Press the SET/CLEAR button to reserve or cancel the Smart Clean function. You can set/clear with out on or off.
1. When the unit stop, press the SMART CLEAN button. Smart Clean symbol will be displayed.
2. To stop Smart Clean function, press the SMART CLEAN button. Smart Clean symbol will disappear. (If Auto Smart Clean is reserved, the symbol will not disappear.)
Manual Smart Clean operation
The brush clean a dust from the filter by moving from left to right or from right to left on the filter. The sucked dust is collected into the dust box. The operating process of Smart Clean is different from the product type.
Sub function
22 Wireless Remote Controller
Electric heater (Optional)
It can only be set during heating operation.
Press the FUNCTION SETTING button 3 times. Electric heater symbol will blink.
1
Press the SET/CLEAR button to reserve or cancel the Electric heater function.
2
• The indoor unit displays during the heating mode, the Auxiliary heater is automatically turned on, but it is not displayed on the wireless remote controller separately.
• It operates in Floor heating mode in Console products.
LCD Luminosity Control (Optional)
Press the LCD LUMINOSITY button. It is comfortable when you feel that the display of the unit too bright .
Celsius/Fahrenheit Switching
Press the °C/°F SWITCH button to change from Celsius to Fahrenheit or from Fahrenheit to Celsius.
Whenever press TEMPERATURE SETTING button in Fahrenheit mode, the temperature will increase/drop 2°F.
Sub function
Ownerʼs & Installation Manual 23
ENGLISH
• There may be differences between wireless remote controller up/down/left/right buttons and the wind discharge port directions.
• Set desired angle with checking the vane angle movement of the product.
• The individual vane control function is an additional function of a product, and it may not work in some products.
Individual vane angle control (Optional)
Press SET/CLEAR button to reserve or cancel the individual vane angle control function.
3
It is the function that can control 4 vane angles individually in the ceiling type 4Way cassette product group.
Press the FUNCTION SETTING button 3 times. (4 times during heating operation) Individual vane angle control symbol will blink.
• If you press the SET/CLEAR button in that time, all vanes are set to standard angle.
1
Set each vane angle by pressing up/down/left/right direction keys.
• Every time the button is pressed, corresponding vane angle and set values are displayed.
• When up direction button is pressed, the display window appears as of the figure in the right, and the angle can be set to 1~6.
• Multi-V Console products can be controlled by up key in the up/down control.
2
Setting Value
4 vanes
Timer
24 Wireless Remote Controller
Timer
• If you wish to cancel all timer setting, press the CLEAR ALL button.
• If you wish to cancel each timer setting, press the TIMER button to turn timer sleep or on or off as you want. And then press the SET/CLEAR button aiming the remote controller at the signal receptor. (The timer lamp on the air conditioner and the display will go off.)
1. Press the TIMER button for 3 seconds.
2. Press TIME SETTING buttons
until the desired time is set.
Check the indicator for A.M. and P.M.
3. Press the SET / CLEAR button.
NOTE
Timer Sleep Timer On Timer Off
1. Press the TIMER button to turn timer on or off.
2. Press TIME SETTING buttons
until the desired time is set.
3. Press the SET / CLEAR button.
Select one of the following 3 types of operation.
NOTE
Setting the Current Time
To cancel the Timer Setting
Timer Setting
Loading...