LG NWC186MCAB1 Owner’s Manual

Room Air Conditioner
(Window Type)
OWNER'S MANUAL
Safety precautions
Safety Precautions .............3
Safety Precautions
Operating instructions
About the Controls on the Air
Conditioner .........................5
Care and Maintenance .......8
Operating Instructions
Installation Instructions
Installation Instructions.........9
Installation Instructions
Troubleshooting tips
Before You
Call for Service..................11
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
CAUTION
Contact the authorized service technician for repair or maintenance of this unit.
Contact the installer for installation of this unit. The air conditioner is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the air conditioner.
Troubleshooting Tips
-2-
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is classified by the following indications.
Safety Precautions
WARNING
CAUTION::
The items to be followed are classified by the following symbo ls.
This symbol shows the po ssibility of causing death or serious injury .
This symbol indi cates the possibility of injury or dama ge to properties only.
Never Do This
Always Do This
WARNING
Plug in the power plug properly.
Otherwise, it will c ause electric shock or fire due to heat generation or ele ctric al shock.
Do not operate or stop the unit by inserting or pulling out the power plug.
It will cause ele ctric al shock or fire due to heat generation.
Do not damage or use an unspecified power cord.
It will cause electrical shock or fire. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
Do not modify power cord length or share the outlet with other appliances.
It will cause ele ctric al shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
It may cause electric al shock.
-3-
Do not direct airflow at room occupants only.
This could damage your health.
CAUTION
Never touch the metal parts
of the unit when removing
the filter.
It may cause an injury.
Safety Precautions
When cleaning the unit, first
make sure the power and
breaker are turned off.
Since the fan rotates at high speed during operation, it may cause an injury.
Do not operate Switches
with wet hands.
It may cause an electric shock. It may cause a fire or deformation
Do not clean the air
conditioner with water.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
Do not put a pet or house
plant where it will be
exposed to direct air flow.
This could injure the pet or plant. Do not use this air conditioner to
Do not apply an insecticide
or flammable spray.
of the cabinet.
Ventilate well when used
together with a stive, etc.
An oxygen shortage may occur.
Do not use for special
purposes.
preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
Do not put a heater, etc.
where is exposed to direct air
It may cause imperfect combustion.
flow.
-4-
About the Controls on the air conditioner
The controls will look like the following.
Controls
OPERATION
TEMPERATURE OPERATION
AUTO SWING
0
Wait for 3 minutes before restart
THERMOSTAT (TEMPERATURE)
The THERMOSTAT/TEMPERATURE is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number (the right side) and the indoor air will become cooler. The 5 or 6 position (the middle position of arc) is a normal setting for average conditions.
THERMOSTAT (TEMPERATURE)
The THERMOSTAT/TEMPERATURE is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. The temperature is selected by turning the THERMOSTAT/ TEMPERATURE knob to the desired position.
HEATER LAMP
At the heating operation, the lamp is lighted. When the frost settles on the heat exchanger of the outside, defrosting is made automatically and the lamp is unlighted. After defrosting, the heating operation begins again.
AUTO SWING
Auto swing switch controls the horizontal air direction by air swing system (not on all models). ON Auto swing is operated. OFF Auto swing is not operated.( ) : ( ) :
High Cool ( ), Med Cool ( ) and Low Cool
speeds. air circulation and filtering without cooling. Off ( O ) turns the air conditioner off.
NOTE:
Cooling Descriptions
For Normal Cooling- Select High Cool or Med Cool
with the OPERATION knob at the midpoint of THERMOSTAT/TEMPERATURE knob.
For Maximum Cooling- Select High Cool with the OPERATION knob at the highest number available on your THERMOSTAT/TEMPERARURE knob.
For Quieter & Nighttime Cooling- Select Low Cool with the OPERATION knob at the midpoint of THERMOSTAT/TEMPERATURE knob.
( ) provide cooling with different fan
Med Fan
( ) or Low Fan ( ) provides
If you move the switch from a cool setting to
off or to a fan setting, wait at least 3
minutes before switching back to a cool
setting.
OPERATION
HIGH ( ) Cool, LOW ( ) Cool provide cooling with different fan speeds. HIGH ( )heat, LOW( ) heat provide heating with different fan speeds. FAN ( ) provides air circulation and filtering without cooling or
NOTE:
If you move the switch from the cool(or the
heating. OFF ( O ) turns the air conditioner off.
heat) setting to off or to a fan setting, wait at least 3 minutes before switching back to a cool (or heat) setting.
Cooling Descriptions
For Normal Cooling- Select HIGH Cool with the OPERATION
knob at the midpoint of the THERMOSTAT/TEMPERATURE knob. For Maximum Cooling- Select HIGH Cool with the OPERATION knob at the clockwise available on the THERMOSTAT/TEMPERATURE knob.
For Quieter & Nighttime Cooling- Select LOW Cool with the OPERATION knob at the midpoint of the THERMOSTAT/
Heating Descriptions
TEMPERATURE knob.
For Normal Heating- Select HIGH heat with the OPERATION knob at the midpoint of the THERMOSTAT/TEMPERATURE knob.
For Maximum Heating- Select HIGH heat with the OPERATION knob at the counterclockwise available on the THERMOSTAT/TEMPERATURE knob.
For Quieter Heating- Select LOW heat with the OPERATION knob at the midpoint of the THERMOSTAT/TEMPERATURE knob.
Operating Instructions
-5-
2 3
REMOTE CONTROLLER
Mode Timer
Fan Cod On
Dry Energy Saver
Fan Speed Temp Auto Swing Power
4 5 6
POWER BUTTON
1
Operation starts, when this button is pressed and stops when you press the button again.
OPERATION MODE SELECTION BUTTON
Operating Instructions
2
Select Cooling Fan or Dehumidification (Dry) mode with this button.
ON/OFF TIMER/SLEEP BUTTON
3
Set the time of on/off operation. The timer can be set by the one hour for a maximum of 12 hours. In the
first 30 minutes set temperature increases by 1°C and in the next 30 minutes temperature increases by another 1°C, this temperature then remains till the timer function is activated. This is how the sleep
function behaves.
FAN SPEED SELECTOR
4
Select the fan speed in Three steps Low (F1) / Med. (F2) / High (F3)
ROOM TEMPERATURE SETTING BUTTON
5
Control the room temperature within a range of 16°C to 30°C.
AUTO SWING
6
The vertical louver swings horizontally by the automatic system and stops when you press the button again.
SIGNAL RECEIVER
7
ENERGY SAVER
8
The fan stops when the compressor stops cooling. Approximately even 3 minutes the fan will turn on and check the room air to determine if cooling is needed.
AUTO RESTART
In failure of electric power the unit runs as previous setting operation when power returns.
How to Insert the Batteries
Remove the cover from the back of the remote
1
controller.
Insert the two batteries.
2
Re-attach the cover.
3
22
7
1
Controls
Precaution:
Slide the cover according to the arrow direction.
Be sure that the (+) and (-) directions are correct. Be sure that both batteries are new.
Slide it back into the position.
The Remote Control unit will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Control unit and the air conditioner.
-6-
5
3
8
Do not use rechargeable batteries, such batteries differ from standard dry cells in shape, dimensions, and performance.
Remove the batteries from the remote controller if the air conditioner is not going to be used for an extended length of time.
1
4
2
6
Additional controls and important information.
Vent Control
The vent control is located above the control knobs.
When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.
Air Direction
The direction of air can be controlled horizontally or vertically by using the horizontal louver or vertical louver.
CLOSE VENT OPEN
To open the vent, pull the lever toward you.
To close it, push it in.
Operating Instructions
Horizontal Air-Direction
The horizontal air direction is adjusted by setting the AUTO SWING switch to the ON position.
Vertical Air-Direction
Fingertip pressure on the bank of horizontal louvers adjusts the air direction up or down
-7-
Care and Maintenance
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
Air Filter
Ensure the power is off before open the front Grill. The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. The grille is designed to clean the filter both upward and downward.
To remove:
Open the inlet grille upward by pulling out the bottom of the
1
inlet grille or downward by pulling out the top of the inlet grille. Using the tab, pull up slightly on the filter to release it and pull
2
it down or up.
Clean the filter with warm, soapy water below 40°C (104°/F).
Operating Instructions
3
Rinse and gently shake the water from the filter and let it dry
4
before replacing it.
CAUTION:
DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.
(Optional)
Drainage
In humid weather, excess water may cause the BASE PAN to overflow.
1
To drain the water, remove the DRAIN CAP.
BASE PAN
To remove the condensed water, you can install the drain pan as below.
2
Take the drain pan which is located in the air discharge.
1. Install the drain pan to the right corner of the cabinet with 4 screws.
2. Connect the drain hose to the outlet located at the bottom of the drain
3. pan. You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied).
-8-
CABINET
DRAIN
PAN
SCREW
DRAIN HOSE
(Optional)
DRAIN CAP
Loading...
+ 16 hidden pages