LG LW-C1036CL Owner's Manual

M
ROOM
AIR
CONDITIONER OWNER'S
Please
precautions operating
read
your
carefully
operating
room
MANUAL
instructions
thoroughly
conditioner.
ACONDICIONADOR
DE
MANUAL
precauciones
de
ventana.
VENTANA
favor
instalar
y
operar
DEL
instrucciones
de
seguridad
su
PROPIETARIO
de
cuidadosa
acondicionador
before
DE
operacion
totalmente
y
de
safety
installing
AIRE
y
aire
de
antes
TABLE
OF
CONTENTS
FEATURES
OPERATING
FUNCTION VENTILATION TO
CONTROL
HOW
AIR
TO
FILTER
INSTALLATION
BEFORE
REQUESTING
FEATURES
...........................................................................................................
.........................................................................................................
.........................................................................................................
....................................................................................................
AIR
DRAIN
................................................................................................
CLEANING
INSTRUCTIONS.......................................................................
DIRECTION
.....................................................................................
SERVICE
........................................................................
.....................................................................
2
3 3
4 4
5 5 5
7
1.
CABINET
2.
HORIZONTAL
(VERTICAL
3.
VERTICAL
(HORIZONTAL
4.
AIR
DISCHARGE
5.
FRONT
AIR
6.
INTAKE
(INLET
LOUVER)
AIR
GRILLE
GRILLE)
AIR
DEFLECTOR
DEFLECTOR
LOUVER)
-2-
7.
8.
9.
10.
11.
12.
13.
14.
AIR
FILTER
CONTROL POWER EVAPORATOR
CONDENSER
COMPRESSOR BASE BRACE
BOARD
CORD
PAN
OPERATING
?
CAUTION
When
the
air
the
fan
position,
FUNCTION
conditioner
waitatleast3minutes
has
been
performing
before
its
cooling
resetting
operation
to
the
andisturned
cooling
operation
off
or
again.
set
to
?
THERMOSTAT
Thermostat
temperature
for
lower
is
selected
position.
The
5
average
room
by
or
6
position
conditions.
will
automatically
of
the
room.
temperature.
turning
isanormal
8
the
9
7
6
THERMOSTAT
Select
The
knob
5
control
higher
temperature
to
the
setting
1
4
the
number
desired
for
2
3
BEFORE WAIT
THREE
RESTARTING
MED
LOW
MINUTES
?
OPERATION
OFF
MED
LOW
HIGH
MED
LOW
LOW
OPERATION
FAN
FAN
COOL
COOL
COOL
HIGH
MED
:
Turns
:
Permits
operation
:
Permits
operation
:
Permits
speed
:
Permits fan
speed
:
Permits
speed
the
air
conditioner
the
medium
without
the
low
without
cooling
operation.
cooling
operation.
cooling
operation.
fan
cooling.
fan
speed
cooling.
with
the
with
the
with
the
off.
speed
high
medium
low
fan
fan
-3-
VENTILATION
The
ventilation conditions. When
fresh
air
The
damperisopened
lever
is
necessary
must
and
beinthe
in
the
room
CLOSE
room,
airisexhausted.
position
set
the
in
ordertomaintain
ventilation
levertothe
OPEN
Part
the
best
position.
cooling
Part
CLOSE
NOTE:
TO
CONTROL
The
directionofair the
vertical
VENT
Before makeaventilation
part
louver.
using
to
horizontal
can
the
ventilation
kit.
line
AIR
be
controlled
OPEN
feature,
pull
part
down
First,
with
DIRECTION
wherever
.
want
to
you
?
HORIZONTAL
The
ing
cool
horizontal
the
vertical
by
adjusting
AIR-DIRECTION
air
louver
the
direction
right
horizontal
CONTROL
is
adjusted
or
left.
louver
by
and
rotat-
-4-
?
VERTICAL
The the
vertical
horizontal
AIR-DIRECTION
air
direction
louver
forward
CONTROL
is
adjustedbyrotating
or
backward.
HOW
DRAIN PIPE
TO
DRAIN
BASE
PAN
be
air
proper
sure
conditioner
First,
installation.
The for
Generally
drain
pipe.(See
water
the
to
air
insert
the
drain
must
be
drainage.
conditioner
description)
pipe
installed
may
drain
into
base
with
a
condensation
pan
slight
before
tilttothe
through
outside
the
AIR
The
particles
causes
1.
2.
3.
4.
air
Open
Remove
Wash
Gently
FILTER
filter
should
in
the
an
accumulation
the
inlet
the
the
filter
shake
INSTALLATION
CLEANING
be
will
filter
grille
air
filter
using
the
excess
checked
buildupand
of
upward
from
lukewarm
at
least
frostonthe
by
pulling
the
front
water
water
from
INSTRUCTIONS
twiceamonth
block
the
cooling
out
grille
assembly
below
the
filter
to
airflow.
coils.
the
bottom
This
of
by
40°C(104°F).
completely.
if
see
reduces
the
pulling
Replace
cleaning
the
inlet
grille.
the
air
filter
the
is
necessary.
cooling
up
filter.
capacity
slightly.
Trapped
and
also
1.
Remove
at
both
the
sides
screws
andatthe
which
fasten the
back.
cabinet
-5-
Shipping
screws