website http://www.lgservice.com
email http://www.lgservice.com/techsup.html
LG
LG Ceiling suspended Type Air Conditioner
INSTALLATION MANUAL
MODELS: VL, VK, VJ Chassis
IMPORTANT
•Please read this instruction manual completely before installing the product.
•When the power cord is damaged, replacement should be performed by authorized personnel only.
•Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
•Please retain this installation manual for future reference after reading it thoroughly.
<![endif]>DEUTSCH FRANÇAIS ESPAÑOL ITALIANO ENGLISH
Room Air Conditioner Installation Manual
TABLE OF CONTENTS
Installation |
|
Requirements |
|
Safety Precautions............................ |
3 |
Introduction........................................ |
8 |
Symbols used in this manual.......... |
8 |
Features ........................................... |
8 |
Installation .......................................... |
9 |
Installation parts............................... |
9 |
Installation tools ............................... |
9 |
Installation map.............................. |
10 |
Selecting the best location ........... |
11 |
Piping Length and Elevation......... |
12 |
Preparing Work for Installation ..... |
12 |
Mounting the anchor Nut & |
|
Bolt(Ceiling Mounting)................... |
13 |
Drill a Hole in the Wall................... |
14 |
Installation instructions of |
|
Indoor Unit installation................... |
14 |
Flaring Work................................... |
15 |
Connecting of Piping - Indoor....... |
16 |
Connection of the pipes- |
|
Outdoor .......................................... |
18 |
Connecting the Cables.................. |
18 |
Checking the Drainage ................. |
21 |
Forming the Piping ........................ |
22 |
Air Purging ..................................... |
23 |
Side Cover Assembly.................... |
25 |
Test Running.................................. |
26 |
Required Parts
Four type "A" screws & plastic anchors
Connecting cable
Installation guide map
Pipes: Gas side .............. |
3/8", 1/2" |
Liquid side ................... |
1/4" |
Insulation materials
Additional drain pipe
(Outer diameter |
..............15.5mm) |
Two type "B" screws
Required Tools
Level gauge
Screw driver
Electric drill
Hole core drill
(ø25mm, ø45mm, ø70mm)
Horizontal meter
Flaring tool set
Specified torque wrenches 1.8kg.m, 4.2kg.m, 5.5kg.m, 6.6kg.m
(different depending on model No.)
Spanner ........................Half union
A glass of water
Screw driver
Hexagonal wrench(4mm)
Leak detector
Vacuum pump
Gauge manifold
Owner's manual
Thermometer
Remote control holder
2 Ceiling suspended Type Air Conditioner
Safety Precautions
Safety Precautions
people and property damage, the following instructions must be
the air conditioner.
specified here as they include important items related to safety. instruction will cause harm or damage. The seriousness is classified
symbol indicates the possibility of death or serious injury.
symbol indicates the possibility of injury or damage to properties only.
this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
<![endif]>ENGLISH
Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.
•There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
•There is risk of fire or electric shock.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
For electrical work, contact |
Always ground the product. |
|||||
the dealer, seller, a qualified |
|
|
|
|
||
electrician, or an Authorized |
|
|
|
|
||
Service Center. |
|
|
|
|
||
• Do not disassemble or repair |
• There is risk of fire or |
|||||
the product. There is risk of |
electric shock. |
|||||
fire or electric shock. |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Always install a dedicated |
Use the correctly rated |
circuit and breaker. |
breaker or fuse. |
• Improper wiring or |
• There is risk of fire or |
installation may cause fire or |
electric shock. |
electric shock |
|
Installation Manual 3
Safety Precautions
Do not modify or extend the power cable.
•There is risk of fire or electric shock.
For installation, always contact the dealer or an Authorized Service Center.
•There is risk of fire, electric shock, explosion, or injury.
Do not install, remove, or reinstall the unit by yourself (customer).
•There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand.
•It may cause injury, accident, or damage to the product.
Be cautious when unpacking and installing the product.
•Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.
Be sure the installation area does not deteriorate with age.
•If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
•Moisture may condense and wet or damage furniture.
Do not plug or unplug the power supply plug during operation.
■ Operation
Take care to ensure that power cable could not be pulled out or damaged during operation.
•There is risk of fire or electric shock.
Do not place anything on the power cable.
•There is risk of fire or electric shock.
Do not touch(operate) the |
Do not place a heater or other |
product with wet hands. |
appliances near the power cable. |
•There is risk of fire or electric shock.
•There is risk of fire or electrical shock.
•There is risk of fire and electric shock.
|
|
Safety Precautions |
|
|
|
Do not allow water to run |
Do not store or use flammable |
Do not use the product in a |
into electric parts. |
gas or combustibles near the |
tightly closed space for a |
|
product. |
long time. |
• It may cause There is risk |
• There is risk of fire or failure |
• Oxygen deficiency could |
of fire, failure of the product, |
of product. |
occur. |
Gasolin
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.
•Do not use the telephone or turn switches on or off.
There is risk of explosion or
Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
•There is risk of physical injury, electric shock, or product failure.
If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable.
•There is risk of electric shock or fire.
When the product is soaked (flooded or submerged), contact an Authorized Service Center.
•There is risk of fire or electric shock.
Stop operation and close the window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives.
•There is risk of property damage, failure of product, or electric shock.
Be cautious that water could not enter the product.
•There is risk of fire, electric shock, or product damage.
<![endif]>ENGLISH
to time when |
Turn the main power off when cleaning or |
etc. |
maintaining the product. |
shock. |
• There is risk of electric shock. |
Installation Manual 5
Safety Precautions
When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker.
•There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody could step on or fall onto the outdoor unit.
• This could result in personal injury and product damage.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
hose to |
Keep level even when |
||
|
||||
|
||||
|
|
is drained |
installing the product. |
|
. |
|
|
|
|
|
|
may |
• To avoid vibration or water |
|
|
leakage. |
leakage. |
|
90˚ |
people to |
Do not install the product |
the |
where it will be exposed to sea |
|
wind (salt spray) directly. |
injury. |
• It may cause corrosion on the product. |
|
Corrosion, particularly on the condenser |
|
and evaporator fins, could cause product |
|
malfunction or inefficient operation. |
Do not expose the skin directly to cool air for long periods of time.
(Don't sit in the draft.)
• This could harm to your health.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.
• There is risk of damage or loss of property.
6 Ceiling suspended Type Air Conditioner
Safety Precautions
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
•There is risk of fire, electric shock, or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter. They are very sharp!
•There is risk of personal injury.
Wax |
Thinner |
|
Do not step on or put anyting on the product. (outdoor units)
•There is risk of personal injury and failure of product.
Do not drink the water drained from the product.
Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
•A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
Use a firm stool or ladder when cleaning or maintaining the product.
• It is not sanitary and could |
• Be careful and avoid |
cause serious health issues. |
personal injury. |
Do not insert hands or other objects through the air inlet or outlet while the product is operated.
•There are sharp and moving parts that could cause personal injury.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.
•There is risk of fire or explosion
<![endif]>ENGLISH
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
• They may burn or explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.
•The chemicals in batteries could cause burns or other health hazards.
Installation Manual 7
Introduction
Introduction
Symbols
used
in
this
Manual
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the air conditioner.
NOTICE This symbol indicates special notes.
Features
|
Air Discharge |
Right Side Cover |
|
Air Filter |
Receptor |
|
|
Inlet Grill |
Left Side Cover |
|
Power Cord |
Air Intake Vents |
Connecting |
|
|
|
Wires |
Piping
Drain Hose
Air Outlet Vents
Base Plate
8 Ceiling suspended Type Air Conditioner
Installation
Installation
Read carefully, and then follow step by step.
Installation
Parts
Hanging bolt(W3/8 or M10)
Nut(W3/8 or M10)
Flat washer for M10(accessory)
Spring washer(M10)
Flat washer for M10(accessory)
Nut(W3/8 or M10)
Installation
Tools
Figure |
Name |
Figure |
Name |
|
Screw driver |
|
Ohmmeter |
Electric drill |
Hexagonal wrench |
Measuring tape, Knife |
Ammeter |
Hole core drill |
Gas-leak detector |
|
Spanner |
Thermometer, |
|
Horizontal meter |
||
|
Torque wrench |
Flaring tool set |
<![endif]>ENGLISH
Installation Manual 9