LG LT1234CNR User Manual [en, es]

your air conditioner and retain it for future reference.
TYPE WINDOW
MODELS LT1034CNR , LT1234CNR , LT1434CNR
MFL68124902
2 Room Air Conditioner
Window-Type Air Conditioner Owner’s Manual
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first,youmaynotneedtocallfor service at all.
PRECAUTION
Contact the authorized service technician for repair
or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young
children or invalids without supervision.
• Young children should be supervised to ensure that
they do not play with the air conditioner.
• When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only using only genuine replacement parts.
• Installation work must be performed in accordance
with the National Electric Code by qualified and authorized personnel only.
Safety Precautions..........................3
Before Operation.............................7
Introduction ....................................8
Electrical Safety ..............................9
Installation ....................................11
Operating Instructions .................18
Maintenance and Service ............21
Safety Precautions
WARNING
Gasolin
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
WARNING
CAUTION
Meanings of symbols used in this manual are as shown below.
Installation
Don’t use a power cord, a plug, or a loose socket which is damaged.
Otherwise, it may cause a fire or electrical shock.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Be sure not to do.
Be sure to follow the instruction.
Always plug into a grounded
Always plug into a grounded
outlet.
outlet.
Otherwise, it may cause a fire or electrical shock.
Do not modify or extend the
Do not modify or extend the
power cord length.
power cord length.
It will cause electric shock or fire due to heat generation.
ENGLISH
Do not disassemble or modify products.
It may cause failure and electric shock.
Be caution when unpacking and installing.
Sharp edges may cause injury.
Do not store flammables like
gasoline, benzene, thinner, etc.
near the air conditioner.
It may cause explosion or fire.
Owner’s Manual 3
Wax
Thinner
Safety Precautions
Operation
Do not place heavy object on the power cord and take care so that the cord should not be pressed.
There is danger of fire or electric shock.
Do not share the outlet with other appliances.
It will cause electric shock or fire due to heat generation.
Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands.
Otherwise, it may cause a fire or electrical shock.
Do not place the power cord near a heater.
It may cause fire and electric shock.
Unplug the unit if strange sounds, odors, or smoke come from it.
Otherwise it may cause fire and electric shock accident.
No correlation between fan usage and oxygen depletion.
An oxygen shortage may occur.
Do not allow water to run into electric parts.
It will cause failure of machine or electric shock.
Do not open the suction inlet grill of the product during operation.
Otherwise, it may electrical shock and failure.
Turn off the power and breaker first when cleansing the unit.
Since the fan rotates at high speed during operation, it may cause injury.
Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
If water enters the product, turn off the the power switch of the main body of appliance. Contact service center after taking the power-plug out from the socket.
Unplug the unit when not using it for a long time.
Prevent accidental startup and the possibility of injury.
4 Room Air Conditioner
Owner’s Manual 5
ENGLISH
Safety Precautions
CAUTION
Do not operate or stop the unit by inserting or pulling out the power plug.
It will cause electric shock or fire due to heat generation.
Hold the plug by the head when taking it out.
It may cause electric shock and damage.
Do not damage or use an unspecified power cord.
It will cause electric shock or fire.
When gas leaks, open the window for ventilation before operating the unit.
Otherwise, it may cause explosion, and a fire.
Do not operate with wet hands or in damp environment.
It will cause electric shock.
Never touch the metal parts of the unit when removing the filter.
They are sharp and may cause injury.
For inner cleaning, contact an Authorized Service Center or a dealer. Do not use harsh detergent that causes corrosion or damage on the unit.
Harsh detergent may also cause failure of product, fire, or electric shock.
Installation
Install the product so the exhaust and noise are not aimed directly at the neighbors.
Be considerate.
Follow installation instructions exactly.
Otherwise, it may cause vibration or water leakage.
Do not use this appliance for special purposes such as cooling pets,
foods, precision
machinery, or objects of art.
Instead of running air conditioning constantly
open a window
for fresh air occasionally.
You will feel better.
If the liquid from the battery gets onto your skin or clothers
wash it well with clean water. Do
not use the remote if the battery has leaked.
y
If you eat the liquid from the battery,brush your teeth and see doctor.Do not use the remote if the battery have leaked.
y
2. No correlation between fan usage and oxygen depletion.
3.
7
8 Room Air Conditioner
Introduction
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the air conditioner.
This symbol indicates special notes.
NOTICE
This appliance should be installed in accordance with the National Electric Code.
Introduction
Symbols Used in this Manual
Features
THE SLEEVE AND THE REAR GRILLE
(optionally supplied with your unit)
SLEEVE ASSEMBLY (Including Aluminum Rear grille)
AIR FILTER
INLET GRILLE
VERTICAL AIR DEFLECTOR
(Horizontal Louver)
(Air Intake)
HORIZONTAL AIR DEFLECTOR
(Vertical Louver)
REAR GRILLE (Aluminum Rear grille)
THE UNIT
AIR DISCHARGE
CABINET
FRONT GRILLE
VENT CONTROL
RESET
TEST
should be
Avoid shock hazard. This unit cannot be user-serviced. Do N27open the tamper-resistant sealed portion. All warranties and performance will be voided. This unit is not intended to be used as an ON/OFF switch.
9
10
Installation
Installation
Remove packing materials from the wall sleeve and tape from the air conditioner.
INSTALLATION REQUIREMENTS
If you use an existing wall sleeve, you should
measure its dimensions. Install the new air conditioner according to these installation instructions to achieve the best performance. All wall sleeves used to mount the new air conditioner must be in good structural condition and have a rear grille to securely attach the new air conditioner. (Figure 1)
With the LGE sleeve(optionally supplied with your unit), you can maintain the best performance of
the new air conditioner. (Figure 2)
20-3/32"
(511 mm)
Air Conditioner
Aluminum metal grille
LGE Wall Sleeve
ELECTRICAL SERVICE
Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on left side of cabinet).
All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to make the necessary corrections. SA storage and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use.
24"(610 mm)
14-13/32" (366 mm)
18-15/32"(468 mm)
25-7/8"
(656 mm)
15-17/32" (394 mm)
16-23/32" (425 mm)
VE CARTON for
Figure 1
Figure 2
INSTALLATION HARDWARE
2 Size options
3
2 Size options
2 4
5
6
7
4
1
8
9
ITEM NAME OF PARTS Q'TY
1 PLASTIC GRILLE 1 2 VERTICAL INSULATION STRIP 1 3 AROUND INSULATION STRIPS 2 4 HORIZONTAL INSULATION STRIP 1 5 SUPPORT BLOCK 2 6 BAFFLE 1 7 TRIM FRAME 2 8 SHIM 2 9
PLASTIC NUTS AND WASHER SCREWS
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time.
Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils.
Make sure air conditioner does not fall during installation.
REQUIRED TOOLS:
Tight Fitting gloves
Standard screwdriver
Phillips screwdriver
Pliers
Sharp knife
3/8-inch open end
wrench or adjustable wrench
1/4-inch hex socket and ratchet
Tape measure
Electric drill
1/4-inch drill bit
ENGLISH
Owner’s Manual 11
12 Room Air Conditioner
Installation
INSTALLATION
We strongly recommend the removal of the old wall sleeve and the installation of a new LGE Wall Sleeve.
If you decide to keep the existing wall sleeve, you have to redirect the louvers at the back of the wall sleeve illustration. The use of pliers is recommended. If you DO NOT redirect, you run the risk of poor performance or product failure. This is not covered under the terms of the LGE warranty.
Pick a location which will allow the conditioned air to blow into the area you want. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed.
ITEMS IN INSTALLATION HARDWARE
You may not need all parts in the kit. Discard unused parts.
Plastic grille 26
ITEM (inches) Qty.
Vertical insulation strip 15 Around Insulation Strips
Horizontal Insulation Strip 23 Support Block 1 Baffle Shim x 1 x Trim Frame 2 Washer Screw 4 Nuts (Plastic) 4 Grille Rear 1
67 59
3
14 x
1
8
3
1
/
/
x 16
4
2
9
3
/
/
x 1
16
8
1
3
/
/
x 1
8
8
27
3
/
/
x 1
32
3
7
/
/32
x 1
8
3
/
/
x 1
x 4
4
8
1
/
4
x
2
3
/
/
4
2
x
8
x 1
x 1
1
/
25
x 1
5
8
1
3
/
1
8
/
1
32
3
/
1
8
3
/16
1
/
2
16
1 2
NOTICE
All wall sleeves used to mount the new air conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the air conditioner.
Remove the old airconditioner from existing wall
2
sleeve. Clean the interior of the existing sleeve.
3
(Do not disturb seals.) Wall sleeve must be securely fastened in wall
4
before installing the air conditioner. Use the nails or screws through sleeve into wall, if needed. Repaint sleeve if needed.
Prepare the wall sleeve for installation of the
5
unit. If you plan to use your existin and it is not LGE, use procedure B or C below.
Procedure Brand
A LGE 16-23/32
White-Westinghouse Frigidaire Carrier (52F series) General Electric
B
/Hotpoint Whirlpool 17-1/8 or 23 Carrier (51S series)
Fedders/Emerson
C
Emerson/Fedders 15 Friedrich 16-3/4
Install new unit into wall sleeve.
6
g wall sleeve,
Depth(inches)
16, 17-1/2
or 22
16-7/8
18-5/8 16-3/4
or 19-3/4
HOW TO INSTALL
Identify the existing wall sleeve before installing
1
the unit from the listed below.
Brand
White-Westinghouse Frigidaire Carrier (52F series) General Electric /Hotpoint
Whirlpool 25-7/8 16-1/2
Fedders/Emerson 27 16-3/4
LGE 25-7/8 15-17/32 16-23/32 Emerson/Fedders 26-3/4 15-3/4 15 Carrier (51S Series) 25-3/4 16-7/8 18-5/8 Friedrich 27 16-3/4 16-3/4
Wall Sleeve Dimensions (inches)
Width Height Depth
25-1/2 15-1/4
16, 17-1/2
or 22
26 15-5/8 16-7/8
17-1/8
or 23
16-3/4
or 19-3/4
When installation is completed, the replacement unit MUST have a rearward slope as shown. To achieve 1/4" slope, remove the backing from the 8-1/2" shim strips and attach them as shown below in Fig. 3. Place the higher portion of the shim to the front of the rib on the base of the wall sleeve.
1" high
Shim
6" 6"
SHIM PLACEMENT UNIT INSTALLATION
FRONT
1/4"
3
/4" High
UNIT
Wall Sleeve
Figure 3
Installation
PROCEDURE A
If you are using the new sleeve (optionally
1
supplied with your unit), skip to step 3. Otherwise, install the plastic grille from the kit. Cut the plastic grille to 25-1/2" wide and 15­1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.
Fasten the 4 washer screws to secure the grille
2
to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.
Figure 4
Install the new unit into the wall sleeve.
4
To assemble trim,
5
into the slot of the other piece as shown below.
snap the tab of each piece
Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below.
Trim (2 ea)
Wall
ENGLISH
ENGLISH
7 erugiF
or
Remove the backing from the vertical insulation
3
strip 15
9
3
x 1
3
/
/
x 1
and attach that to the
8
8
/
16
inside right of the sleeve as shown below. Remove the backing from the around insulation
1
3
strip 67
/
8
x 1
25
/
/
x
and attach that to the
8
32
inside front of the sleeve as shown below.
Indoor Outdoor
Around Insulation
Vertical Insulation
9 1/2" 6"
Figure 5
Figure 6
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
Make sure air conditioner does not fall during removal.
If unit does not operate after installation check, to be sure the circuit interrupter has not been tripped. Refer to the Troubleshooting guide for reset procedure.
Owner’s Manual 13
Installation
PROCEDURE B
Redirect the louvers at the back of the wall
1
The use of pliers is recommended.
3
7
/
"
60°
Rear Louvers
(Top View)
If the wall sleeve already has a rear grille, skip
2
to step 4. If the wall sleeve does not have a rear grille or louvered panel, install the plastic grille from the kit. Cut the plastic grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.
32
.8 erugiF ni nwohs sa elgna °06 ot eveels
60°
Figure 8
Remove the backing from the Vertical Insulation
4
strip 15
9
3
x 1
3
/
/
x 1
and attach that to the
8
8
/
16
inside right of the sleeve as shown below.
ve the backing from the Around Insulation
Remo
1
3
strip 67
/
8
x 1
25
/
/
x
and attach that to the
8
32
inside front of the sleeve as shown below.
Indoor Outdoor
Around Insulation
Vertical Insulation
9 1/2" 6"
If the depth of your existing wall sleeve is less
5
than or equal to 18", skip to step 6. Otherwise, cut the baffles and the support blocks according to length A in the table below.
Depth D of the existing wall sleeve (inches)
8
D 19-3/
8
4
18 D 18-5/
18-5/
19-3/4 D 22
Length A
(inches)
3
/4
1-3/4
4
A
A
Figure 11
Support Block
Baffle
Figure 12
Place the plastic grille
Fasten the 4 washer screws to secure the grille
3
to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.
or
Fasten the screws
14 Room Air Conditioner
Figure 9
Figure 10
Owner’s Manual 15
PROCEDURE B
8
Remove the backing from the support blocks
6
and attach them to the inside of the wall sleeve as shown Figure 13 . Slide the baffle into slots of the support blocks.
Wall
in
(
Installation
3
7
"
)
/
32
Wall
Sleeve
Front
Install the new unit into the wall sleeve.
7
Assemble trim as described in Step 5, Procedure A.
Baffle
Support Block
Figure 13
CAUTION
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
Make sure air conditioner does not fall during removal.
If unit does not operate after installation check, to be sure the circuit interrupter has not been tripped. Refer to the Troubleshooting guide for reset procedure.
Loading...
+ 33 hidden pages