Prior to installation, this air-conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-3 Norm).
ENGLISH
кмллдав ьбхд
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips Care and Maintenance Operating Instructions Safety Precautions
2
WARNING
WARNING
CAUTION
CAUTION
WARNING
WARNING
Safety precautions
Safety Precautions
Warning ................................2
Caution .................................3
Operating Instructions
Preparation before operation
..4
Remote Control Features .....6
Operation Mode Selection ......7
Additional features..............14
Care and Maintenance
Care and Maintenance .......18
Operation Tips....................20
Troubleshooting tips
Before You
Call For Service...............21
To prevent injury and property damage, follow these instructions.
Incorrect operation due to ignoring instructions will cause harm or damage, the seriousness of which is indicated by the following symbols.
This symbol shows the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
The following items are classified by these symblos.
Never Do This
Always Do This
Plug in the power plug properly.
Do not operate or stop the unit by inserting or pulling out the power plug.
Do not damage or use an unspecified power cord.
• Otherwise, it will cause electric shock or fire due to heat generation or electric shock.
• It will cause electric shock or fire due to heat generation.
• It will cause electric shock or fire.
In the supply cord is damaged, it mut be replaced by the manufacturer or its service agent or a similarly quallfied person in order to avoid a hazard. (Y Attachment)
Do not modify power cord length or share the outlet with other appliances.
Do not operate with wet hands or in damp environment.
Do not direct airflow at room occupants only.
• It will cause electric shock or fire due to heat generation.
• It may cause electric shock. • This could damage your health.
Always perform grounding work. Do not allow water to run into
electric parts.
Always install air leakage breaker and a dedicated switching board.
• No grounding may cause electric shock.
• It may cause failure of machine or electric shock.
• No installation may cause fire and electric shock accident.
Unplug the unit if strange sounds, smell, or smoke comes from it.
Do not use the socket if it is loose or damaged.
Do not open the entrance during operation.
• It may cause fire and electric shock accident.
• It may cause fire and electric shock.
• It may cause electric shock.
Keep firearms away.
Do not use the power cord close to the heating tools.
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
• It may cause fire. • It may cause fire and electric shock. • It may cause an explosion or fire.
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips
3
CAUTION
CAUTION
WARNING
WARNING
Never touch the metal parts of the unit when removing the filter.
Do not clean the air conditioner with water.
Ventilate well when used together with a stove, etc.
• They are sharp and may cause injury.
• Water may enter the unit and degrade the insulation. It may cause an electric shock.
• An oxygen shortage may occur.
When cleaning the unit, first make sure the power and breaker are turned off.
Do not put a pet or house plant where it will be exposed to direct air flow.
Do not use appliance for special purpose such as animals or vegetables, precision machine, or conservation of art articles.
• Since the fan rotates at high speed during operation, it may cause injury.
• This could injure the pet or plant.
• It may cause damage of animals or vegetables or loss of property.
Stop operation and close the window in storm or hurricane.
Hold the plug by the head of the power plug when taking it out.
Turn off the main power switch when not using it for a long time.
• Operation with windows opened may cause wetting of indoor and soaking of household furniture.
• It may cause electric shock and damage.
• It may cause failure of product or fire.
Do not place obstacles around the absorption inlet or instead of blowing-out inlet.
Ensure that an installation console of the outdoor appliance is not damaged due to the use for a long time.
Always insert the filters securely. Clean it once every two weeks.
• It may cause failure of appliance or accident.
• If leaving appliance damaged, there is concern of damage due to the falling of product.
• Operation without filters may cause failure.
Do not use strong detergent such as wax or thinner but use a soft cloth.
Do not place heavy object on the power cord and take care so that the cord should not be pressed.
Do not drink water drained from air conditioner.
• Appearance may be deteriorated due to change of product color or scratching of its surface.
• There is danger of fire or electric shock.
• It contains contaminants and will make you sick.
Ventilate before operating air conditioner when gas goes out.
Do not disassemble or modify products randomly.
• It may cause explosion, fire and, burn. • It may cause failure and electric shock.
Use caution when unpacking and installing. Sharp edges could cause injury.
If water enters the product, turn the power switch of the main body of appliance off. After taking the power-plug out from the socket, contact with the service center.
ENGLISH
4
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips Care and Maintenance Operating Instructions Safety Precautions
Preparation before operation
Storage and Tips For Using the Remote Control
• The remote control may be stored by mounting it on a wall.
• To operate the room air conditioner, aim the remote control at the signal receptor.
How to Insert the Batteries
Remove the battery cover by pulling it according to the arrow direction.
Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
Reattach the cover by sliding it back into position.
NOTES:
• Use 2 AAA(1.5volt) batteries. Do not use rechargeable
batteries.
5
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips
Cooling Mode Lights up during Cooling operation. (Outline)
Auto Operation Mode Lights up during Auto operation. (Outline)
Healthy Dehumidification
Lights up during Healthy Dehumidification operation. (Outline)
Mode
Heating Mode Lights up during Heating operation.
(Heat Pump model only) (Outline)
Defrost Mode Lights up during Defrost control or
Hot Start in Heating operation. (Outline)
Air circulation Mode Lights up during Air Circulation operation. (Outline)
Sleep Mode Lights up during Sleep Mode operation.
Timer Mode Lights up during Timer operation.
Auto Cleaning Mode Lights up during Auto Cleaning reservation.
Jet Cool Mode Lights up during Jet Cool Operation.
Plasma Lights up during Plasma operation.
Fan Speed (Low) Lights up when Fan speed is low.
Fan Speed (Medium) Lights up when Fan speed is Medium.
Fan Speed (High) Lights up when Fan speed is High.
Fan Speed (Chaos) Lights up when Fan speed is Chaos.
Desire temperature
For cooling,dehumidification,heating modes it display Desired temperature
indicator
Cooling : 18~30°C • AI : Auto Operation
Dehumidification : 18~30°C • Po : Jet Cool
Heating : 16~30°C Lo : Test Mode
C1 : Indoor pipe sensor error
Desire temperature Icon
Indoor temperature Icon
ENGLISH
Signal Receptor
Each Icon turns on when the unit is operated, then the only Icon outline to be operated is bright.
ON
OFF
CANCEL
AUTO CLEAN
SET
6
Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips Care and Maintenance Operating Instructions Safety Precautions
1
3
5
4
9
10
17
18
16
7
2
8
13
14 15
11
6
Cooling Operation
Auto Operation
Healthy Dehumidification Operation
Flip-up door (opened)
Heating Operation
Signal transmitter
Cooling Model( ), Heat Pump Model( )
12
About the remote control on the system
The remote control transmits the signals to the system.
Features of the Remote Control- Door Opened
Operation Mode
START/STOP BUTTON
Operation starts when this button is pressed and stops when the button is pressed again.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps low, medium, high and CHAOS.
JET COOL
Used to start or stop the speed cooling. (Speed cooling operates super high fan speed in cooling mode.)
CHAOS SWING BUTTON
Used to stop or start louver movement and set the desired up/down airflow direction.
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation. (See page 14)
TIME SETTING BUTTONS
Used to adjust the time. (See page 14)
TIMER SET/CANCEL BUTTON
Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 14)
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation. (See page 14)
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating. (See page 15)
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
PLASMA(OPTIONAL)
Used to start or stop the plasma-purification function. (See page 12)
HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (NOT ON ALL MODELS)
Used to set the desired horizontal airflow direction. (See page 15)
RESET BUTTON
Used prior to resetting time or after replacing batteries.
2nd F Button
Used prior to using modes printed in blue at the bottom of buttons. (See page 13)
AUTO CLEAN
Used to set Auto Clean mode.
LED LUMINOSITY
Used to adjust LED luminosity.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
7
Safety Precautions Operating Instructions Care and Maintenance Troubleshooting Tips
ON
Cooling
Healthy
Dehumidification
Auto
Heating
(Heat pump model only)
To lower the temperature
To raise the temperature
How to use the Operation Mode Selection button
Press the Start/Stop button. The unit will respond with a beep.
Open the door on the remote control. To select Cooling Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Close the door on the remote control. Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C in 1°C increments.
Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps­low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.
Cooling Operation
1
2
3
4
Natural wind by the CHAOS logic
For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to
CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.
ENGLISH