LG LS240HE, LS090HE, LS120CE, LS240CE, LS120HE User Manual

...
ENGLISH FRANÇAIS ESPAÑOL
LG Room Air Conditioner
LG
• Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after reading it thoroughly.
Prior to installation, this air-conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3 Norm).
IMPORTANT
OWNER'S MANUAL
##############
2 Room Air Conditioner
Room Air Conditioner Owner’s Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Model # Serial #
You can find them on a label on the side of each unit.
Dealer's Name Date Purchased
Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for service at all.
PRECAUTION
Contact the authorized service technician for
repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by authorized personnel only using only genuine replacement parts.
• Installation work must be performed in
accordance with the National Electric Code by qualified and authorized personnel only.
Safety Precautions.........................3
Prior to Operation ..........................9
Introduction..................................10
Electrical Safety ...........................11
Operating Instructions.................12
Maintenance and Service............26
Safety Precautions
Owner’s Manual 3
ENGLISH
Safety Precautions
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
The meanings of the symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
Installation
Do not use damaged power cords, plugs, or a loose socket.
• There is risk of fire or electric shock.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
• There is risk of fire or electric shock.
Always use the power plug and socket with the ground terminal.
• There is risk of electric shock.
Install the panel and the cover of control box securely.
• There is risk of fire or electric shock.
Do not modify or extend the power cord.
• There is risk of fire or electric shock.
Do not install, remove, or re­install the unit by yourself (customer).
• There is risk of fire, electric shock, explosion or injury.
Safety Precautions
4 Room Air Conditioner
Be cautious when unpacking and installing the product.
• Shape edges could cause injury. Be especially careful of the sharp edges.
For installation, always contact the dealer or an Authorized Service Center.
• There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand.
• It may cause injury, accident, or damage to the product.
Be sure the installation area does not deteriorate with age.
• If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Install the indoor unit on the wall where the height from the floors more then 8ft(2.4m)
• There are sharp moving parts that could cause personal injury.
Do not handle the pipe by yourself(Costomer)
• High-Pressure refrigent may cause personal injury.
Use a dedicated outlet for this appliance.
• There is risk of fire or electric shock.
Grasp the plug to remove the cord from the outlet. Do not touch it with wet hands.
• There is risk of fire or electric shock.
Do not allow water to run into electric part.
• There is risk of fire, failure of the product, and/or electric shock.
Operation
8ft(2.4m)
Safety Precautions
Owner’s Manual 5
ENGLISH
Do not place a heater or other appliances near the power cable.
There is risk of fire, failure of the product, and/or electric shock.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
• Moisture may condense and wet or damage furnishings.
Do not store of use flammable gas or combustibles near the air conditioner.
• There is risk of fire or product failure.
Do not use the product in a tightly closed space for a long time.
• Oxygen deficiency could occur.
Some ventilation by opening window is necessary for the fresh air
When flammable gas leaks, turn off the gas and open a window for ventilation before turning the product on. Do not use the telephone or turn switches on or off.
• There is risk of explosion or fire.
Unplug the unit if strange sounds odors or smoke comes from it.
There is risk of fire, Product faiure, and/or electric shock.
Stop operation and close any window in storm or hurricane before the hurricane arrives.
• There is risk of property damage, failure of product, or electric shock.
Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
• There is risk of physical injury, electric shock, or product.
When the product is soaked (flooded or submerged), contact an Authorized Service Center.
• There is risk of electrical shock.
Wax
Thinner
Safety Precautions
6 Room Air Conditioner
Install the drain hose to ensure that water is drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the product.
• To avoid vibration or water leakage.
Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.
• It may cause a problem for your neighbors.
Installation
Take care to ensure that nobody could step on or fall onto the outdoor unit.
• There could result in personal injury and product damage.
Do not insert hands or other objects through the air inlet or outlet while the air conditioner is plugged in.
• There are sharp and moving parts that could cause personal injury.
Always check for gas(refrigerant) leakage after installation or repair of product.
• Low refrigerant levels may cause product failure.
Ventilate the product from time to time when operating it together with a stove, etc.
• There is risk of fire or electrical shock.
Unplug the appliance before performing cleaning or maintenance.
• There is risk of electric shock.
When the product is not be used for a long time disconnect the power supply plug or turn off the breaker.
• There is risk of product damage or failure, or unintended operation.
90˚
Safety Precautions
Owner’s Manual 7
ENGLISH
Use two or more people to lift and transport the air conditioner.
• Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
• It may cause corrosion in the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
Do not direct airflow at room occupants.
• This could damage your health.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.
• There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
• There is risk of fire, electric shock or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter. They are very sharp!
• There is risk of personal injury.
Do not step on or put anything on the product. (outdoor unit)
• There is risk of personal injury and failure of product.
Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
• A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
Operation
Safety Precautions
8 Room Air Conditioner
Do not drink the water drained from the unit.
• It is not sanitary and could cause serious health issues.
Use a firm stool or ladder when cleaning or maintaining the air conditioner.
• Be careful and avoid personal injury.
Replace all the batteries in the remote.
• There is risk of fire or explosion.
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
• They may burn or explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.
The chemicals in batteries could cause burns or other
health hazards.
Disuse
ENGLISH
Owner’s Manual 9
Prior to operation
Prior To Operation
1. Contact an installation specialist for installation.
2. Plug in the power plug properly.
3. Use a dedicated circuit.
4. Do not use an extension cord.
5. Do not start/stop operation by plugging/unplugging the power cord.
6. If the cord/plug is damaged, ony replace it with an authorized replacement part.
1. Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for a long time.
2. Ventilate the room when the air conditioner is used with other heating devices. Otherwise the oxygen supply may be inadequate.
3. Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices, food, pets, plants, or art objects). Such use may damage your properties.
1. Do not touch the metal parts of the unit when removing the filter. Injury can occur.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit power is accidently turned on while the interior of the unit is being cleaned.
For repair and maintenance, contact your authorized service dealer.
Preparing For Operation
Usage
Cleaning And Maintenance
Service
10 Room Air Conditioner
Introduction
Introduction
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the air conditioner.
This symbol indicates special notes.
NOTICE
Features
Symbols Used In This Manual
(Side)
(Rear)
Air outlet vents
Air intake vents
Piping
Signal Receptor
Front Panel
Air Inlet
Air Filter
Indoor
Outdoor
This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features.
ENGLISH
Owner’s Manual 11
Electrical Safety
Electrical Safety
• This appliance must be properly grounded.
To minimize the risk of electric shock, you must alway plug into a grounded oulet
• Do not cut or remove the grounding prong from the power plug.
• Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.
12 Room Air Conditioner
Operating Instruction
How To Insert The Batteries
Operating Instruction
Remove the battery cover by pulling it according to the arrow direction.
Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
Reattach the cover by sliding it back into position.
Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries.
NOTICE
• The remote controler may be stored by mounting it on a wall.
• To operate the room air conditioner, aim the remote control at the signal receptor.
Storage And Tips For Using The Remote Controler
Signal Receptor
Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)
Operation Indication Lamps
On/Off : Lights up during the system operation, error
code and auto restart setting.
Sleep mode : Lights up during sleep mode auto operation. Plasma : The function illustrates its dynamic mode by
using a multiple lighting system.
Timer : Lights up during timer operation. Defrost mode
Power Display : Indicates the setting temperature and operation
mode.
: Lights up during defrost mode or *hot start
operation (Heat pump model only)
: Lights up during outdoor unit operation.
(Cooling model only)
Outdoor unit operation
OUT
DOOR
Operation indicating
lamps
Operating Instruction
Owner’s Manual 13
ENGLISH
ON
OFF
CANCEL
AUTO CLEAN
SET
1
3
5
4
9
10
12
14 16
18
7
2
8
13 15
11
6
Cooling Operation
Auto Operation or Auto Changeover
Healthy Dehumidification Operation
Flip-up door (opened)
Heating Operation
Signal transmitter
Cooling Model( ), Heat Pump Model( )
17
Operation Mode
Controls
Remote Control Operations
1. START/STOP BUTTON
Operation starts when this button is pressed and stops when the button is pressed again.
2. OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
3. ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
4. INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps low, medium, high and CHAOS.
5.
JET COOL
Used to start or stop the speed cooling.(speed cooling operates super high fan speed in cooling mode.)
6. CHAOS SWING BUTTON
Used to stop or start louver movement and set the desired up/down airflow direction.
7. ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation. (See page 22)
8. TIME SETTING BUTTONS
Used to adjust the time. (See page 22)
9. TIMER SET/CANCEL BUTTON
Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 22)
10. SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation. (See page 22)
11. AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating. (See page 23)
12. ROOM TEMPERATURE CHECKING
BUTTON
Used to check the room temperature.
13. NEO PLASMA(OPTIONAL)
Used to start or stop the plasma­purification function. (See page 20)
14. HORIZONTAL AIRFLOW DIRECTION
CONTROL BUTTON (OPTIONAL)
Used to set the desired horizontal airflow direction.
15. RESET BUTTON
Used prior to resetting time.
16. 2nd F Button
Used prior to using modes printed in blue at the bottom of buttons. (See page 21)
17. AUTO CLEAN (OPTIONAL)
Used to set Auto Clean mode.
18. ˚C TO ˚F SWITCHING BUTTON
Used to switch temperature reading from Centigrade to Fahrenheit.
Operating Instruction
14 Room Air Conditioner
ON
Cooling
Healthy
Dehumidification
Auto
Changeover
Heating
(Heat pump model only)
To lower the temperature
To raise the temperature
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Cooling Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Close the door of the remote controller. Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C(64°F~86°F) at intervals of 1°C(2°F).
Set the fan speed again with the door of the remote controller still closed. You can select the fan speed in four steps-low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.
1
2
3
4
Gentle Breeze by the CHAOS logic
For fresher feeling, press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind
blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
Cooling operation
Operating Instruction
Owner’s Manual 15
ENGLISH
ON
Cooling
Healthy
Dehumidification
Auto
Heating
(Heat pump model only)
To lower the temperature
To raise the temperature
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Auto Operation, press the operation mode selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you want to change the set temperature, press the Room Temperature Setting buttons. The cooler or warmer you feel, the more times (up to two times) you should press the button. The set temperature will be changed automatically.
During Auto Operation
You cannot control the indoor fan speed. It has already been set by the Fuzzy rule.If the system is not operating as desired, manually switch to another mode. The system will not
automatically switch from the cooling mode to the heating mode, or from heating mode to cooling mode, it must be done by manually resetting.
During Auto Operation, pressing the CHAOS swing button makes the horizontal louvers swing up and
down automatically. If you want to stop auto-swing, press the CHAOS swing button again.
1
2
3
Auto operation (Optional)
Operating Instruction
16 Room Air Conditioner
ON
Cooling
Healthy
Dehumidification
Auto
Changeover
Heating
(Heat pump model only)
To lower the temperature
To raise the temperature
Auto changeover operation(Optional)
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Auto Changeover Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
1
2
Close the door of the remote controller. Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C(64°F~86°F) at intervals of 1°C(2°F).
Set the fan speed again with the door of the remote controller still closed. You can select the fan speed in four steps-low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.
3
4
During Auto Changeover Operation
The air conditioner changes the operation mode automatically to keep indoor temperature. When room temperature varies over ±2°C from the set temperature, air conditioner keeps the room temperature within ±2°C of the set temperature by auto changeover mode.
Operating Instruction
Owner’s Manual 17
ENGLISH
ON
Cooling
Healthy
Dehumidification
Heating
(Heat pump model only)
Auto
Changeover
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Healthy Dehumidification Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
1
2
Set the fan speed again with the door of the remote controller still closed. You can select the fan speed in four steps-low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
3
Gentle Breeze by the CHAOS logic
For fresher feeling, press the Indoor Fan Speed Selector and set
to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
Healthy dehumidification operation
During Healthy Dehumidification Operation
If you select the dehumidification mode on the operation selection button, the product starts to run the
dehumidification function. It automatically sets the room temp. and airflow volume to the best condition for dehumidification, based on the sensed current room temp.
In this case, however, the setting temperature. is not displayed on the remote controller and you are not able to control the room temperature. either.
During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status, so the room condition is kept healthy and comfortable even in the very humid season.
Operating Instruction
18 Room Air Conditioner
ON
Cooling
Healthy
Dehumidification
Heating
(Heat pump model only)
To lower the temperature
To raise the temperature
Auto
Changeover
Heating operation (Heat pump model only)
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Close the door of the remote controller. Set the temperature higher than the room temperature. The temperature can be set within a range of 16°C~30°C(60°F~86°F) at intervals of 1°C(2°F).
Set the fan speed again with the door of the remote controller still closed. You can select the fan speed in four steps–low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.
1
2
3
4
Gentle Breeze by the CHAOS logic
For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the
wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
Operating Instruction
Owner’s Manual 19
ENGLISH
or or
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely
high speed for 30 minutes setting the room temperature. automatically to 18°C. It is especially used to cool the room temperature. quickly in a hot summer.
In heat pump mode or auto changeover mode, however, the JET COOL function is not available. In order to return to the normal cooling mode from the JET COOL mode, just press the operation
mode selection button, airflow volume selection, temperature. setting button or the JET COOL button again.
NOTICE
Press the Start/Stop button. The unit will respond with a beep.
Press the Jet Cool button to operate the speed cooling mode and the unit will operate at super high fan speed on cooling mode for 30 minutes.
To cancel the Jet Cool mode, press the Jet Cool button, the fan speed button or the room temperature setting button again and the unit will operate at high fan speed on cooling mode.
1
2
3
Jet cool operation
Operating Instruction
20 Room Air Conditioner
Press the Start/Stop button. The unit will respond with a beep.
1
Open the door of the remote controller. Press the PLASMA button.
Operation will start when the button is pressed and stop when the button is pressed again.
2
Set the fan speed again with the door of the remote controller closed. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
Air purifying operation (NEO PLASMA) can be
with cooling, Heating or any other operations.
NEO PLASMA Air Purifying Operation only
If you press the only PLASMA button, only PLASMA purification function operates. Then, fan speed is low. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the Indoor Fan Speed Selector button is pressed, the fan speed mode is shifted.
3
NEO PLASMA purification operation(Optional)
Operating Instruction
Owner’s Manual 21
ENGLISH
ON
OFF
CANCEL
SET
AUTO CLEAN
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller and press the 2nd Function button to operate functions printed blue color under buttons. (Check the indication of 2nd function on the display of the remote controller.)
2nd function disappears in a short time automatically or when the button is pressed again.
1
2
3
2nd F operation
For more details, refer to functions next pages.
Operating Instruction
22 Room Air Conditioner
Delay OFF Timer Delay ON Timer Delay OFF and ON Timer Delay ON and OFF Timer
Sleep mode
1. Press the Sleep Mode Auto button to set the time you want the unit to stop automatically.
2. The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner.
3. Make sure the Sleep Mode Auto LED lights up . To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star( ) disappears from the operation display.
The Sleep Mode will be operated at slow fan speed (cooling) or medium fan speed (heat pump only) for a comfortable sleep.
In cooling mode or healthy dehumidification mode:
The setting temperature will automatically rise by 1°C(2°F) over the next 30 minutes and by 2°C(4°F) in 1 hour for a comfortable sleep.
NOTICE
Setting the time
1. Time can be set only when you press the Reset button. When you replace the batteries, you should press the reset buttons to reset the time. Press the Start/Stop button.
2. Press 2nd F button and check if 2nd F icon is on.
3. Press the Time Setting buttons until the desired time is set.
4. Press the Timer SET button.
Check the indicator for A.M. or P.M.
NOTICE
1. Make sure the time is set correctly on the display of the remote controller.
2. Press 2nd F button.
3. Press the ON/OFF Timer buttons to turn Timer on or off.
4. Press the Time Setting buttons until the desired time is set.
5. To set the selected time, press the Timer setting button aiming the remote controller at the signal receptor.
To cancel the timer setting
Check if 2nd F icon is off. Press the Timer Cancel button aiming the remote controller at the signal receptor. (The timer lamp on the air conditioner and the display will go out.)
Delay start/Pre-set stop
Select one of the following four types of operation.
NOTICE
with the unit running
ON
OFF
CANCEL
SET
CANCEL
SET
CANCEL
SET
Additional Features
Operating Instruction
Owner’s Manual 23
ENGLISH
Fan speed is on low. Fan speed is on medium. Fan speed is on high.CHAOS Air
The up/down airflow (Vertical Airflow) can be adjusted by using the remote control.
1. Press the Start/Stop button to start the unit.
2.Open the door on the remote control. Press Chaos Swing button and the louvers will swing up and down. Press the Chaos Swing button again to set the vertical louver at the desired airflow direction.
If you press the CHAOS swing button, the vertical
airflow direction is changed automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable, as if enjoying a natural breeze.
Always use the remote control to adjust the up/down
airflow direction. Manually moving the vertical airflow direction louver by hand could damage the air conditioner.
When the unit is shut off, the up/down airflow direction
louver will close the air outlet vent of the system.
To adjust left/right(Horizontal Airflow) direction
Ensure unit is turned off before adjusting the horizontal airflow direction control. Carefully open vertical louver to allow access to the horizontal airflow direction.
Adjust the left/right airflow direction by hand.
NOTICE
Air Circulation Mode
Circulates the room air without cooling or heating.
1. Press the Start/Stop button. the unit will respond with a beep.
2. Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS and back to low again.
CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.
NOTICE
Vertical Airflow Direction Control
24 Room Air Conditioner
Operating Instruction
AUTO CLEAN
ON/OFF
button
During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy
Dehumidification Operation can be removed.
During Auto Clean function, only Start/Stop button, Plasma button and AUTO CLEAN button are
available.
NOTICE
Auto clean (Optional)
1. Whenever you press the AUTO CLEAN button, Auto Clean Function will be reserved and cancelled.
2. Auto Clean function works before and after cooling or dehumidification mode. For details, refer to the below points.
3. When the unit is started after the reservation of Auto Clean ,the Cool Start function operates and indoor Fan is started after 20 seconds.
4. When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean function, the air-conditioner circulates the indoor air in the Auto Clean mode with no more Cooling or Dehumidification operation. It lasts for 30 minutes.
5. If you press the AUTO CLEAN button again during the product operation , Auto Clean function will be cancelled.
Operation procedures when the remote control can't be used. The operation will be started if the ON/OFF button is pressed. If you want to stop operation, re-press the button.
Forced operation
Heat pump Model
Cooling Model
Room Temp. 24°C(75.2°F)
21°C(69.8°F) Room Temp. < 24°C(75.2°F)
Room Temp. < 21°C(69.8°F)
Operating mode Cooling Cooling Healthy Dehumidification Heating
Indoor FAN Speed
High High High High
Setting Temperature
22°C(71.6°F) 22°C(71.6°F) 23°C(73.4°F) 24°C(75.2°F)
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller sets. If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep". If you want to stop the operation, re-press the button.
Operating Instruction
Owner’s Manual 25
ENGLISH
High
Speed
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. So there is no need of activating this function by pressing any key or button. In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode.
Auto restart function has set enable as factory default. But customer can set up by following this instruction.
To disable function
- Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) blinks 4 times.
To enable function
- Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) brights 4 times.
NOTICE
Helpful information
Fan speed and cooling capacity. The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room quickly.
26 Room Air Conditioner
Maintenance and Service
Maintenance And Service
Indoor Unit
Before performing any maintenance, turn off the main power to the system.
Grille, Case, and Remote Control
Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
Supply power must be disconnected before cleaning the indoor unit.
Air filters
The air filters behind the front grille should be checked and cleaned once in every 2 weeks or more often if neccessary.
1.
Open the front panel as shown.
2. Pull the filter tab slightly forward to remove the filter.
3. Clean the filter with a vacuum cleaner or warm, soapy water.
• If dirt is conspicuous, wash with a solution of detergent in lukewarm water.
• If hot water (40°C(104
°F)
or more) is used, it may be
deformed.
4. After washing with water, dry well in the shade.
5. Re-install the air filter.
NEO PLASMA filter (Optional)
The NEO PLASMA filter behind the air filters should be checked and cleaned once in every 3 months or more often if necessary.
1. After removing the air filters, pull slightly forward to remove the NEO PLASMA filter.
2. Clean NEO PLASMA filter with the vacuum cleaner. If it is very dirty, wash it with water.
3. Note the cuts of electric discharge lines.
4. Re-install the NEO PLASMA filter to the original position.
TRIPLE DEODORIZER filter (Optional)
1. After removing the air filters, pull slightly forward to remove the TRIPLE DEODORIZER filter.
2. Dry in the sunlight for two hours.
3. Re-install the TRIPLE DEODORIZER filter to the original position.
NOTICE
Don't touch this NEO PLASMA Filter within 10 seconds after opening he inlet grille, it may cause an electric shock. Never use any of the followings:
Water hotter than 40°C(104
°F)
Could cause deformation and/or discoloration.
Volatile substances Could damage the surfaces of the air conditioner.
Vertical louver
Horizontal louver
Air filters (behind front panel)
Air outlet ventAir inlet vent
G
a
s
o
l
i
n
e
P
o
w
d
e
r
NEO PLASMA Filter
TRIPLE DEODORIZING Filter
Maintenance and Service
Owner’s Manual 27
ENGLISH
(Side)
(Rear)
Air outlet vents
Air intake vents
Piping
Outdoor Unit
The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned.
Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.
NOTICE
Common Problems And Solutions
Before calling for service, please review the following list of common problems and solutions.
The air conditioner is operating normally when:
• You hear a pinging noise. This is caused by water being picked up by the fan on rainy days or in highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency.
• You see water dripping from the rear of the unit. Water may be collected in the base pan in highly humid conditions or on rainy days. This water overflows and drips from the rear of the unit.
• You hear the fan running while the compressor is silent. This is a normal operational feature.
Before calling for service
If you have problems with your air conditioner, read the following information and try to solve the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer.
Air conditioner does not operate
1. Ensure that the air conditioner is plugged into a proper outlet.
2. Check the fuse or circuit breaker.
3. Check whether the voltage is unusually high or low.
Air does not feel cold enough on the cooling setting
1. Ensure that the temperature settings are correct.
2. Check to see if the air filter is clogged with dust. If so, replace the filter.
3. Ensure that the air flow from the outside is not obstructed and that there is a clearance of over 20" between the
back of the air conditioner and the wall or fence behind it.
4. Close all doors and windows and check for any source of heat in the room.
Loading...
+ 60 hidden pages