LG LRNN246BHA0, LRNV186BHA0, LRNV246BHA0, LRNN186BHA0 INSTALLATION MANUAL

System
Heat Pump Indoor Unit
INSTALLATION MANUAL
LG
MODELS: LRNN, LRNV-BE/BG/BH Series Type: Ceiling Concealed Duct - High Static
website http://www.lgservice.com
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it thoroughly.
Ceiling Concealed Duct - Low Static Type Indoor Unit Installation Manual
TABLE OF CONTENTS
Installation Requirements
Installation Parts Provided....3
Safety Precautions.................4
Installation
Selection the best location ....7
Ceiling opening dimension
and hanging bolt location ......8
Wiring Connection .................9
Required Parts Required Tools
Installation guide mapFour type "A" screws & plastic
anchors
Connecting cable
Pipes: Gas side
Liquid side (Refer to Product Data)
Insulation materialsAdditional drain pipe
Level gaugeScrew driverElectric drillHole core drillHorizontal meter
Flaring tool setSpecified torque wrenches
(different depending on model No.)
Spanner .......Half union
Check the Drainage.............10
Installation of Remote
Control..................................13
Drain Pipe Work...................14
Installation of Drain Pump ...16
Optional Operation ..............18
Twotype"B"screws
A glass of waterScrew driver
Hexagonal wrenchGas-leak detectorVacuum pumpGauge manifold
Owner's manualThermometer
2 Indoor Unit
Air filters
Remote Controller
Air intake vents
Air outlet vents
Installation
Name
Quantity
Shape
for gas pipe
for liquid pipe
Clamp metal
1 EA
Insulation for
fitting
1 set 1 set
Drain hose
1 EA
(Other)
Clamp
6 EA
Screws for
duct flanges
• Owner's manual
• Installation manual
• Washers(8 pcs.)
Installation Parts Provided
Installation Manual 3
3
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Be sure to read before installing the air conditioner.
Be sure to observe the cautions specified here as they include important items related to safety.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the
following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
Installation
Do not use a defective or under­rated circuit breaker. Use this appliance on a dedicated circuit.
•Thereisriskoffireorelectricshock.
Install the panel and the cover of control box securely.
•Thereisriskoffireorelectricshock.
For electrical work, contact the dealer, seller, a qualified electri­cian, or an Authorized Service Center.
• Do not disassemble or repair the product. There is risk of fire or elec­tric shock.
Always install a dedicated cir­cuit and breaker.
• Improper wiring or installation may cause fire or electric shock
Always ground the product.
•Thereisriskoffireorelectricshock.
Use the correctly rated breaker or fuse.
•Thereisriskoffireorelectricshock.
4 Indoor Unit
Safety Precautions
Do not modify or extend the power cable.
• There is risk of fire or electric shock.
For installation, always contact the dealer or an Authorized Service Center.
• There is risk of fire, electric shock, explosion, or injury.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
• Moisture may condense and wet or damage furniture.
Do not install the product on a defective installation stand.
• It may cause injury, accident, or damage to the product.
Be cautious when unpacking and installing the product.
• Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.
Be sure the installation area does not deteriorate with age.
• If the base collapses, the air condi­tioner could fall with it, causing prop­erty damage, product failure, and personal injury.
Operation
Do not store or use flammable gas or combustibles near the product.
• There is risk of fire or failure of product.
Gasolin
Installation Manual 5
Safety Precautions
Installation
Always check for gas (refriger­ant) leakage after installation or repair of product.
• Low refrigerant levels may cause failure of product.
Do not install the product where the noise or hot air from the out­door unit could damage the neighborhoods.
• It may cause a problem for your neighbors.
Install the drain hose to ensure that water is drained away prop­erly.
• A bad connection may cause water leakage.
Use two or more people to lift and transport the product.
• Avoid personal injury.
Keep level even when installing the product.
• To avoid vibration or water leakage.
90˚
Do not install the product where it will be exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product. Corrosion, particularly on the con­denser and evaporator fins, could cause product malfunction or inefficient operation.
6 Indoor Unit
Loading...