P/No. : 3A02045K
PACKAGE AIR CONDITIONERS
INSTALLATION INSTRUCTIONS
Please read this instruction sheets completely before using the products
Applied Model:
(1) 28K/30K(Btu/h)
(3) 44K/50K(Btu/h)
(2) 80K(Btu/h)
2
Contents
1. Installation of Indoor, Outdoor Unit
..................................................................
3
2. Connecting the Cable to Indoor Unit
................................................................
4
3. Power Supply and Wiring
..................................................................................
5
4. Checking the Drainage
.......................................................................................
6
5. Final Check and Test Run
..................................................................................
7
Note.
Please, call the service center and ask an authorized personnel for installation, if
you wish to install at a particular or another place.
5/8" 3/8" 10 5
3/4" 5/8"
15 7
3/4" 3/8"
3/4" 1/2" 15 7
3
1. Installation of Indoor, Outdoor unit
5cm
5cm 40cm
100cm
Indoor unit
1) Selection of the best location
¤ Indoor unit
¤ŁOutdoor unit
¤ØPiping length and the elevation
• There should not be any heat source or
steam near the unit.
• There should not be any obstacles to prevent
the air circulation.
• A place where air circulation in the room will
be good.
• A place where drainage can be easily
obtained.
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from
the wall, ceiling, fence, or other obstacles.
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful
that heat radiation from the condenser is not
restricted.
• There should not be any animals or plants
which could be affected by discharged hot air.
• Ensure the space indicated by arrows from
the wall, ceiling, fence, or other obstacles.
28K/30K
(BTU/h)
80K
(BTU/h)
44K/50K
(BTU/h)
50Hz
60Hz
Pipe Size
MODEL
GAS LIQUID
Max.
length
A (m)
Max.
Elevation
B (m)
Wall
More
than
50cm
Indoor unit
Outdoor
unit
B
More than
50cm
More than
100cm
More than
50cm
A
Outdoor unit