LG LP1419IVSM user manuals

OWNER’S MANUAL
AIR CONDITIONER
Read this owner’s manual thoroughly before operating the appliance and keep it handy for reference at all times.
TYPE: PORTABLE AIR CONDITIONER (INVERTER)
www.lg.com
Copyright © 2019 - 2020 LG Electronics Inc. All Rights Reserved.
TABLE OF CONTENTS
3 IMPORTANT SAFETY INSTRUCTIONS
11 PRODUCT OVERVIEW
11 Key Parts and Components
12 INSTALLATION
12 Electrical Data 13 Before Installation the Air Conditioner 13 Wireless Remote Control 14 Preparing for Installation 14 Selection of Installation Location 15 Window Vent Panel and Extensions 16 Installation (Vertical) 16 Installation (Horizontal)
20 OPERATION
20 Control Panel and Remote Control 21 Removing Condensation Buildup
22 LG ThinQ Application 24 Smart Diagnosis
TM
25 MAINTENANCE
25 Emptying the Water Collection Tank 25 Cleaning the Case 25 Cleaning the Air Filter
26 TROUBLESHOOTING
26 Before Calling for Service 26 Normal Sounds You May Hear
The following symbols are displayed on units.
This symbol indicates that this appliance uses a flammable refrigerant. If the refrigerant is is leaked and exposure to an external ignition source, there is a risk of fire.
This symbol indicates that the Operation Manual should be read carefully.
This symbol indicates that a service personnel should be handling this equipment with reference to the Installation Manual.
This symbol indicates that information is available such as the Operating Manual or Installation Manual.
SAFETY INSTRUCTIONS
4
When the power cord is to be replaced, replacement work shall be performed by authorized
personnel only using only genuine replacement parts.
and authorized personnel only.
Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.
Always plug into a grounded outlet. Do not under any circumstances, cut or remove the third (ground) prong from the power cord. When installing or moving the appliance, be careful not to pinch, crush, or damage the power
cord. Plug in the power plug properly.
Do not modify or extend the power cord. Do not start/stop operation by plugging/unplugging the power cord.
If the cord/plug is damaged, have it replaced by an authorized service person using authorized
replacement parts. Use a dedicated circuit. Do not disassemble or modify the product. Adhere to all industry recommended safety procedures including the use of long-sleeved gloves
and safety glasses.
Use care when unpacking and installing. The edges of the product may be sharp. Disconnect the power cord or circuit breaker before installing or servicing the appliance.
Keep packaging materials out of the reach of children. These materials can pose a suffocation
risk to children.
Store and install the product where it will not be exposed to temperatures below freezing or
exposed to outdoor weather conditions.
other appliance.
Do not install the unit in potentially explosive atmospheres.
OPERATION
Use this appliance only for its intended purpose. Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled,
or has missing or broken parts, including a damaged cord or plug.
Repair or immediately replace all power cords that have become frayed or otherwise damaged.
Do not use a cord that shows cracks or abrasion damage along its length or at either end. Do not run cord under carpets or mats where it could be stepped on and damaged. Keep the cord out from under heavy objects like tables or chairs.
Do not place the power cord near a heat source. Do not use an adaptor or plug the product into a shared outlet. Do not tamper with controls. If you detect a strange sound, a chemical or burning smell, or smoke coming from the appliance,
unplug it immediately, and contact an LG Electronics Customer Information Center.
straight out from the outlet. Do not grasp the power cord or touch the appliance controls with wet hands.
The air conditioner is not intended for use by young children or invalids without supervision.
Young children should be supervised to ensure that they do not play with the air conditioner.
SAFETY INSTRUCTIONS
5
If water enters the product, turn off the power at the main circuit, then unplug the product and call
for service. If the product has been submerged, contact the LG Electronics Customer Information Center for
instructions before resuming use. Unplug the product when unused for long periods. Unplug the product before cleaning. In the event of a gas leak (propane gas, etc.) do not operate this or any other appliance. Open a
window or door to ventilate the area immediately. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
To clean the interior, contact the LG Electronics Customer Information Center or dealer. Using harsh detergents may cause corrosion or damage to the unit.
Do not use solvent-based detergent on the product. Doing so can cause corrosion or damage,
GROUNDING INSTRUCTIONS
The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with
a standard three-slot (grounding) wall power outlet to minimize the hazard of electric shock. The
sure the receptacle is properly grounded. DO NOT CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER PLUG.
- Situations when the appliance will be disconnected occasionally; Because of potential safety hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from most local hardware stores. The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polarity connection.
Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded
to make sure the receptacle is properly grounded. Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter
ground terminal might break. Do not use the appliance with a broken adapter plug.
- Situations when the appliance will be disconnected often; Do not use an adapter plug in these situations. Unplugging the power cord frequently can lead to an eventual breakage of the ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet instead.
Keep any required ventilation openings clear of obstruction. Ducts connected to an appliance shall not contain an ignition source. The appliance must only be supplied at safety extra low voltage corresponding to the marking on
the appliance. This appliance incorporates an earth connection for functional purposes only. This appliance is not intended to be accessible to the general public. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
EN
SAFETY INSTRUCTIONS
6
CAUTION
To reduce the risk of minor or moderate injury to persons, malfunction, or damage to the product or property when using this product, follow basic precautions, including the following:
INSTALLATION
Take care when installing the product that exhaust or condensation does not damage nearby
property.
Follow installation instructions exactly to avoid excessive vibration or water leakage.
OPERATION
This appliance is not intended for use as a precision refrigeration system. Do not use it for special
purposes such as maintaining pets, food, precision machinery, or art objects.
When installing or moving the appliance, be careful not to pinch, crush, or damage the power
cord. Make sure the air inlet and outlet are free from obstructions. Use a soft cloth to clean the appliance. Do not use waxes, thinners, or harsh detergents. Do not step on or place heavy objects on top of the appliance.
Do not drink water drained from the appliance.
are used simultaneously.
Remove the batteries if the remote control is not to be used for an extended period of time. Never mix different types of batteries, or old and new batteries for the remote control.
consult a doctor. Do not recharge or disassemble the batteries.
MAINTENANCE
Never use strong cleaning agents or solvents when cleaning the air conditioner or spray water.
Use a smooth cloth.
In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must
not be supplied through an external switching device, such as a timer, or connected to a circuit
that is regularly switched on and off by the utility.
IMPORTANT SAFETY INSTRUCTIONS
7
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Checks to the area
Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed.
Work procedure
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
General work area
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
Checking for presence of refrigerant
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
Presence of fire extinguisher
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.
No ignition sources
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
Ventilated area
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable refrigerants:
– The actual refrigerant charge is in accordance with the room size within which the refrigerant containing
parts are installed.
– The ventilation machinery and outlets are operating adequately and are not obstructed.
– If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence
of refrigerant.
– Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be
corrected.
– Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any
substance which may corrode refrigerant containing components, unless the components are constructed of
materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
Checks to the refrigeration equipment
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Checks to electrical devices
EN
IMPORTANT SAFETY INSTRUCTIONS
8
Initial safety checks shall include: – Capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking. – No live electrical components and wiring are exposed while charging, recovering or purging the system. – Continuity of earth bonding.
During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being
worked upon prior to any removal of sealed covers, etc.
Particular attention shall be paid to the following to ensure that by working on electrical components, the
casing is not altered in such a way that the level of protection is affected.
This shall include damage to cables, excessive number of connections, terminals not made to original
specification, damage to seals, incorrect fitting of glands, etc.
Ensure that apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of
preventing the ingress of flammable atmospheres.
Replacement parts shall be in accordance with the manufacturer’s specifications.
If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently
operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
Repairs to sealed components
When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures
shall be used. However, it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to:
– Remove refrigerant. – Purge the circuit with inert gas. – Evacuate. – Purge again with inert gas. – Open the circuit by cutting or brazing.
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not
exceed the permissible voltage and current permitted for the equipment in use.
Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable
atmosphere.
The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
Repair to intrinsically safe components
Cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse
environmental effects. The check shall also take into account the effects of ageing or continual vibration from sources such as compressors or fans.
Cabling Check
Under no circumstances shall potential sources of ignition be used in the searching for or detection of
refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.
Detection of flammable refrigerants
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants.
Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
If a leak is suspected, all naked flames shall be removed/extinguished.
Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the
system, or isolated (by means of shut off valves) in a part of the system remote from the leak.
Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine
shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work.
Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the
refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed.
Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate,
or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.)
Leak detection methods
Removal and evacuation
IMPORTANT SAFETY INSTRUCTIONS
9
– Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them. – Cylinders shall be kept upright. – Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. – Label the system when charging is complete (if not already). – Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be “flushed” with
OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
In addition to conventional charging procedures, the following requirements shall be followed.
Charging procedures
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment
and all its detail.
It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required
prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation. b) Isolate system electrically.
d) Pump down refrigerant system, if possible.
f ) Make sure that cylinder is situated on the scales before recovery takes place. g) Start the recovery machine and operate in accordance with manufacturer's instructions. h) Do not overfill cylinders. (No more than 80 % volume liquid charge). i ) Do not exceed the maximum working pressure of the cylinder, even temporarily.
k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
j ) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
c) Before attempting the procedure ensure that:
Decommissioning
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The
label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
Labelling