Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and
obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “WARNING” or “CAUTION”.
These words mean:
WARNING This symbol indicates the possibility of death or serious injury.
CAUTIONThis symbol indicates the possibility of injury or damage to property.
BASIC SAFETY PRECAUTIONS
WARNING To reduce the risk of fire, electric shock, or injury
to persons when using this appliance, follow basic precautions, including the following:
English
• Do not attempt to repair or replace any part
of your air conditioner unless it is specifically
recommended in this manual. All other services
should be referred to a qualified technician.
• If the power cord becomes worn or damaged,
the cord should only be replaced by a qualified
service technician using genuine replacement
parts.
• The air conditioner should be plugged into its
own grounded 15A, 60 Hz., 120 VAC circuit.
• Do not plug other appliances into the same
outlet; it can overload the circuit and cause a fire
or electric shock.
• Do not remove the round grounding prong from
the plug. It can result in the risk of electric shock.
• This air conditioner is not designed for use by
young children. Young children should be
supervised to ensure that they do not play with
or climb on the air conditioner.
• Be sure all packaging materials are removed
from the air conditioner before use. It can result
in personal injury.
• Do not disassemble or modify the air conditioner
or the power cord. It can result in the risk of
electric shock or fire.
• Do not place the power cord or air conditioner
near a heater, radiator, or other heat source. It
can result in the risk of electric shock or fire.
• Do not use this or any appliance near flammable
gases or liquids or other combustibles, such as
gasoline, benzene, thinner, etc. It can result in
the risk of electric shock or fire.
• Make sure the power cord is plugged firmly and
completely into the outlet. It can result in the risk
of electric shock or fire.
• Do not start or stop operation by plugging in or
unplugging the power cord. It can result in the
risk of electric shock.
• If the air conditioner is making unusual sounds or
is emitting smoke or an unusual odor, unplug it
immediately. It can result in the risk of electric
shock or fire.
• Do not use if the electrical socket is loose or
damaged. It can result in the risk of electric
shock or fire.
• Do not operate with wet hands or in a damp
environment. It can result in the risk of electric
shock.
• Do not use this or any electrical appliance if you
smell gas. It can result in the risk of fire or
explosion.
• Turn off and unplug the air conditioner before
cleaning to avoid the risk of electric shock.
• Do not clean the unit with water. Water can enter
the unit and damage the insulation, creating a
shock hazard. If water enters the unit, unplug it
immediately and contact Customer Service. It
can result in the risk of electric shock.
• Use two or more people to lift and install the
unit. Failure to do so can cause back injury or
other injuries.
3
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
BASIC SAFETY PRECAUTIONS
CAUTION To reduce the risk of fire, electric shock, or injury to persons when
using this appliance, follow basic precautions, including the following:
• To avoid possible cuts, avoid contacting the
metal parts of the air conditioner when removing
or reinstalling the filter. It can result in the risk of
personal injury.
• Do not block the air inlet or outlet of the air
conditioner. Reduced air flow will result in poor
performance and could damage the unit.
• Always grasp the plug when plugging in or
unplugging the air conditioner. Never unplug by
pulling on the cord. It can result in result in the
risk of electrical shock and damage.
• Always turn off and unplug the air conditioner
when it will not be used for extended period of
time. This conserves energy and reduces the
chance of accidents.
• Secure the wheels with blocks to prevent the air
conditioner from rolling on smooth floors.
• Install the air conditioner on a sturdy, level floor
capable of supporting up to 110 lbs (50 kg).
Installation on a weak or unlevel floor can result
in result in the risk of property damage and
personal injury.
• Make sure the air conditioner is the correct size
for the area you wish to cool. Using an air
conditioner that is the wrong size can waste
energy and damage the air conditioner.
• Close all doors and windows to the room for
most efficient operation.
• To prevent damage to the surface finish, use only
a soft cloth to clean the air conditioner. Do not
use wax, thinner, or a strong detergent.
• To prevent spills and property damage, be sure
to drain the air conditioner properly.
• To prevent the coils from freezing, do not operate
the air conditioner if the room temperature is
below 18°C (65°F).
• Do not position the air conditioner so that
pets or house plants are exposed to the
direct air flow. It can result in the risk of injury
to pets or house plants.
• This air conditioner is designed for normal
household use. Do not use for cooling pets,
foods, precision machinery, or art objects.
• Do not drink the water from the drain pan.
Dispose of it properly outdoors or down
the drain.
• Do not operate air conditioner without the filter
securely in place. Operation without the filter
could damage the unit.
• Clean the filter every two weeks, or more often
if needed.
ELECTRICAL SAFETY
• This air conditioner must be plugged
WARNING
Electrical Shock Hazard
Failure to follow these instructions can result
in death, fire, or electrical shock.
• This unit must be properly grounded.
• Do not, under any circumstances, cut or
remove the ground prong.
• If you do not have a properly grounded
outlet, or if there is any doubt that the outlet
is not properly grounded, a qualified
electrician should check the outlet and
circuit, and, if necessary, install a properly
grounded outlet.
4
into a grounded 60 Hz, 120 VAC outlet
protected by a 15 amp time delay fuse
or circuit breaker.
• This air conditioner must be installed in
accordance with national wiring codes.
• Do not alter or modify the plug or cord
of this air conditioner. If the power cord
becomes worn or damaged, the cord should
only be replaced by a qualified service
technician using genuine replacement parts.
• Do not use an extension cord.
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
ELECTRICAL SAFETY
INTEGRATED CIRCUIT BREAKER
For additional safety,
the power cord
Reset
Test
button does not cause the circuit breaker to trip,
or if the RESET button will not stay engaged,
unplug the air conditioner immediately and
contact your LG service technician.
Due to potential safety hazards, the use of
an adapter plug is strongly discouraged.
For temporary connections, use only a
UL-listed adapter. Ensure that the large slot
in the adapter is aligned with the large slot
in the outlet.
To prevent damage to the adapter’s ground
terminal, hold the adapter in place while
plugging in or unplugging the air conditioner.
• Attaching the adapter ground terminal to
the wall receptacle cover screw does not
ground the appliance unless the cover
screw is metal and not insulated, and the
wall receptacle is grounded through the
house wiring.
features an integrated
circuit breaker. Test
and reset buttons are
provided on the plug
case.
The circuit breaker
should be tested
periodically by
pressing the TEST
PREFERRED
GROUNDING METHOD
Ensure proper
ground exists
before use.
English
TEMPORARY GROUNDING
METHOD
(Use of adapter
plugs not
permitted
in Canada)
Ensure proper
ground exists
before use.
• Frequent connection and disconnection
can damage the ground terminal on the
adapter. Never use a broken or damaged
adapter.
SAVE THESE INSTRUCTIONS
5
PARTS AND FEATURES
KEY PART AND COMPONTS
1
AIR DISCHARGE
The direction of air can be controlled wherever you want to cool
by adjusting the horizontal louver.
Adjusting the horizontal louver up and down will change
vertial airflow.
2
CONTROL PANEL AND DISPLAY
Easy-to-read digital display shows the set temperature and
indicator lights show the operating mode. Simple push buttons
make changing settings quick and easy.
3
SWIVELING CASTERS
Swiveling casters allow you to move the air conditioner easily
on most floor surfaces.
4
INTEGRATED HANDLES
Integrated handles provide a convenient grip when lifting the
air conditione
5
INFRAED REMOTE CONTROL
The remote control allows you to adjust the temperature
and operate most functions of the air conditioner
from across the room.
2
4
3
5
9
1
6
EXHAUST AIR OUTLET VENT
Insert the large adapter end of the hose into the hole on the
back of the air conditioner.Align the pins on the connector with
the slots in the hole. Twist slightly clockwise until it locks into place.
7
BOTTOM DRAIN PORT
Used when water tank is full or free of using long time.
Before moving the unit, drain the internal water collection
tank completely by using bottom drain port.
8
AIR FILTER
9
HOSE
Use the di
Use the diffuser and hose to connect the air conditioner to the
window installation kit to vent exhaust air outside.
AND DIFFUSE
Check all the accessories included in the package and
please refer to the installation instructions for their usage.
6
6
8
7
PART AND FEATURES
CONTROL PANEL AND REMOTE
6
43
Operation of functions is the same when using the remote or the control panel,
unless otherwise stated.
For detailed instructions on each function,see the following pages.
1
POWER
Operation begins when this button is pressed and stops
when you press the button again.
MODE
2
Press this button to select FAN, COOL,AUTO mode.
FAN SPEED
3
Adjusts the circulation fan speed between HIGH,
LOW fan speed.
4
TIMER
Press this button to set TIMER ON, TIMER OFF
or NO TIME
5
UP & DOWN
Press these buttons to set room temperature
or time when in Time On/Off mode.
6
LED Display
Display different signals accordingly.
5
2
1
3
9
7
4
English
5
2
8
8
1
1
7
SLEEP MODE
Setting sleeping mode, the temperature will rise
1 °C after 2 hours, and another 2 hours later, rise 1 °C
8
CELSIU AND FAHRENHEIT EXCHANGE BUTTON
9
CONTINUOUS
After setting mightiness, the unit will keep running no matter
what temperature it sets, and E4
NOTE
E1E2 E3 protection works.
To vary from Fahrenheit to Celsius, press both UP and DOWN button
HOW TO USE
B
BEFORE USING YOUR AIR CONDITIONER
PREPARING FOR OPERATION
Refer to the Installation Instructio ns included in
Refer to the Installation Instructio ns included in
this manual before using the air conditioner.
this manual before using the air conditioner.
Once the air conditioner has been properly
Once the air conditioner has been properly
assembled and installed:
assembled and installed:
Plug the power cord into its own dedicated
1
properly grounded outlet.
rrly grounded outlet.
her appliances
it could overload the outlet and create a
it could overload the outlet and ca
fir
Make sure the air conditioner and cord is
Make sure the air conditioner and cord is
2
positioned where it does not create a
positioned where it does not create a
tripping hazard and will receive adequate
tripping hazard and will receive adequate
ventilation. Do not place it directly next to
ventilation. Do not place it directly next to
furniture or objects that could block the
furniture or objects that could block the
vent openings.
vent openings.
Make sure that any items that could be
Make sure that any items that could be
3
blown over or damaged by the airflow from
blown over or damaged by the airflow from
the fan are out of the airflow path.
liances
e hazard.
e
are out of thepath.
cointoown dedicate
Do not plug ot
onotplugot
into the same outlet;
into the same outlet;
UNPACKING THEAIRCONDITIONER
Remove and store packing materials for reuse.
Remove any shipping tape before using the
air conditioner. If the tape leaves behind any
adhesive, rub a small amount of liquid dish
soap onto it and wipe with a damp cloth. Do
NOT use sharp instruments, alcohol, thinners,
or abrasive cleaners to remove adhesive.
They could damage the finish.
IMPORTANT:
• Do not remain in the direct airflow from the air
conditioner for extended periods of time.
• To prevent damage or injury to pets and
plants, make sure they are not exposed to
direct airflow from the air conditioner.
• When used at the same time as stoves,
fireplaces, and other combustion devices,
make sure there is a sufficient flow of fresh air
into the room. Do not use in tightly enclosed
spaces with these types of devices.
• This air conditioner is intended for household
use as a consumer comfort appliance. Do not
use it as a precision climate control system,
or for purposes such as cooling precision
equipment, food, pets, plants, artwork, etc.
Such items could be damaged.
• Do not bend the hose downward when
window installation kit is not applied. It may
cause failure of air conditioner or performance
deterioration.
BEFORE USING YOUR AIR CONDITIONER
INSERTING BATTERIES IN THE REMOTE
Before using your remote, install the provided
AAA batteies :
Press in the locking tab on the battery cover
1
on the back of the remote and remove the
cover
Insert two new alkaline AAA batteries into
2
the battery compartment, being sure to note
the proper polarity.
3
Reattach the battery cover, making sure the
locking tab clicks into place.
NOTE :
Use only alkaline batteries. Do not use
噝
rechargeable batteries.
When replacing batteries, always replace both
噝
batteries with new batteries. Do not mix old
and new batteries.
If the air conditioner will not be used for an
噝
extended period of time, remove the batteries
from the remote.
Be sure to note
proper polarity!
H O W TO USE
English
CAUTION
If the liquid from the batteries
Do not use the remote if the
If you eat the liquid from the
The chemicals in batteries could
gets onto
your skin or clothes, wash it well with clean water.
batteries have
batteries,
brush your teeth and see doctor.
cause bur
leaked.
ns or other health hazards.
9
H O W TO U S E
USING THE CONTROLS
Control panel buttons shown. Operation using the remote control is the same, unless
specifically noted.
1. COOLING MODE
· Press MODE button to choose Cool
mode, the Cool mode indicator will flash.
·
Press UP or DOWN button to set room
temperature between 18to 30ćć .
·
Press SPEED button (or High/Low button)
to select high, low fan speed.
2. AUTOMATIC ADJUSTING MODE
· Press POWER to enter the automatic
adjusting mode when the unit is running for
the first time. When room temperature is
higher than25ć, it will come into cool mode.
On the contrary, it will be fan mode. You can
select the fan speed mode and time mode
when it is under automatic adjusting mode.
3. FAN MODE
· Press MODE button (or Fan button) to
choose Fan mode, the Fan mode indicator
will flash.
Select the fan speed by press FAN button
or press High / Low button directly.
4. TIME MODE
· When the appliance is switch off, press
Timer button to set timer-on.
Press Up or Down button to adjust time
·
from 30 minutes to 24 hours. The Time
on indicator will flash.
When the appliance is running, press
·
Timer button to set timer-off.
·
Press Up or Down button to adjust time
from 30 minutes to 24 hours. The Time
off indicator will flash.
5. SLEEPING MODE
· Setting sleeping mode, the temperature
will rise 1ć after 2 hours, and another 2
hours later, rise 1ć
· Then it will keep steady and low fan blow.
6. CONINUOUS
· After setting mightiness, the unit will
keep running no matter what temperature
it sets, and E4ǃE1ǃE2ǃ E3 protection
works.
English
10
·
The temperature can not be set.
High fan blows.
NOTE
噝
Always point the remote at the sensor. The remote may not work if the
sensor is in bright light or if there is not a clear path between the remote
and the sensor.
INSTALLATION INSTRUCTIONS
SELECTION OF INSTALLATION LOCATION
1
Install the unit on a flat and dry place.
2
For best performance,allow at least 50cm
of air space on all sides of the unit for
good air circulation.
WARNING
The length of the exhaust pipe is specially designed according to the specification of this product.
Do not replace or prolong it with your own private hose as this could cause mal-function.
English
11
INSTALLATION INSTRUCTIONS
ATTACHING THE HOSE AND DIFFUSER
NOTE: The air conditioner is shipped with the hose installed. The hose may be removed for cleaning
and storage, if necessary. Simply reverse the steps below to remove.
Insert the large adapter end of the hose into
the hole on the back of the air conditioner.
12
INSTALLATION INSTRUCTIONS
PREPARING FOR INSTALLATION
WARNING The air conditioner is heavy! Use two or more people to
lift and install the unit! Failure to do so could result in back injury or other injuries.
EXHAUST COMPONENTS
The following components are used for window venting.
Not all components are used for every installation.
The window installation kit allows you to install the air conditioner in most vertical-sliding windows 18"
to 48" wide, or casement-style windows from 18" to 48" high.
Small extension
panel
18"
Vent
Panel
18"
Vent
Panel
For an 18" window opening, use the window
vent panel by itself.
Large extension
panel
Large
extension
panel
Vent
Panel
24" − 29"
24" − 29"
Vent
Panel
181⁄4" − 24"
Vent
Panel
Small
extension
181⁄4" − 24"
panel
For window openings from 181⁄4" to 24",
use the window vent panel and the small
extension panel.
Large extension
panel
Large
extension
panel
Vent
Panel
29" − 36"
29" − 36"
Small
extension
panel
Vent
Panel
Vent
Panel
Small
extension
panel
For window openings from 24" to 29",
use the window vent panel and the large
extension panel.
Extension vent
panel
36" − 48"
Extension vent
panel
Large
extension
panel
Vent
Panel
36" − 48"
Small
extension
panel
Large
extension
panel
Vent
Panel
Small
extension
panel
For window openings from 36″ to 48″, use both
vent panels and both extension panels.
For window openings from 29" to 36", use the
window vent panel and both extension panels.
Foam seal A
(Adhesive type)
Foam seal C
(Adhesive type- shorter)
Foam seal B
(Non-adhesive type)
I NS TA LL AT IO NI N ST RU C T I ON S
INSTALLATION IN VERTICAL SLIDING WINDOWS
NOTE: The w indow installation kit can be used with vertical sliding windows between 18"
and 48" wide.
1
Cut the foam seal A(adhesive type) &
C(adhesive type-shorter) to the proper
length, and attach it to the window sash and
frame.
Extension panel
(if required)
Insert the vent panel assembly, including
2
extension panels, if needed, into the window
opening. Extend the extension panels, if
used.
Vent
Panel
English
3
Type B screws
Carefully lower the window. Secure the vent
panel in place with 4 type B screws, plus
one screw for each extension:
Vent panel only:4 type B screws
Vent panel and
one extension:5 type B screws
Vent panel and
two extensions:6 type B screws
Two vent panels and
two extensions:9 type B screws
Cut the foam seal B(Non-adhesive type) to
4
the window width. Stuff the foam seal B
between the glass and the window to
prevent air and insects from getting into the
room.
15
Loading...
+ 33 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.