LG LMNH366BGA0 INSTALLATION MANUAL

INFORMATION
Case 1. Applied combination table Case 2. Applied combination table
P/No.: 3828A30147B
Indoor Unit
Ceiling DuctCassette
LMNH306TFA0
LMNH306TFC0
LMNH366TDA0
LMNH366TDC0
LMNC306TFA0
LMNC306TFC0
LMNC366TDA0
LMNC366TDC0
D
C
B
A
Distributor Unit
• When piping installation work you must use the Y connector to liquid side piping.
LMNH306BGA0
LMNH366BGA0
LMNC306BGA0
LMNC366BGA0
Y connector P/No: 5211A23319A
Outdoor Unit
Socket P/No:5162A20011E
Indoor Unit
Ceiling Duct
LMNC366BGA0
Short tube connector P/No :5211A22140A
• When piping installation work you must use the short tube connector to liquid side piping.
Outdoor Unit
L4UC608FA0
Connection of Piping and Wiring for 30K, 36K Indoor Unit .
PMBD5440L
C
B
A
PMBD5430L
C
B
A
Case 1
Room
Indoor Unit Gas side Liquid side Wiring
A 30K use socket
D
B - - No use
C 12K normal normal C
D 12K normal normal D
Y connector
A
Case 2
Room
Indoor Unit Gas side Liquid side Wiring
A 12K normal normal A
B 12K normal normal B
C 30K Use socket
D - - No use
Y connector
C
* 30K Indoor Unit wire must connect 'A' or 'C' room.
Case 1
Room
Indoor Unit Gas side Liquid side Wiring
A 30K Use socket
B - - No use
C 12K normal normal C
Y connector
A
Case 3
Room
Indoor Unit Gas side Liquid side Wiring
A 30K Use socket
B - - No use
C 24K Use socket normal C
Y connector
A
Case 2
Room
Indoor Unit Gas side Liquid side Wiring
A 30K Use socket
B - - No use
C 18K normal normal C
Y connector
A
Case 4
Room
Indoor Unit Gas side Liquid side Wiring
A 36K Use socket
B - - No use
C 12K normal normal C
Y connector
A
Case 5
Room
Indoor Unit Gas side Liquid side Wiring
A 36K Use socket
B - - No use
C 18K normal normal C
Y connector
A
* 30K, 36K Indoor Unit wire must connect 'A' room
* The Socket converts Pipe size Ø12.7 to Ø15.88.
Loading...