INFORMATION
Case 1. Applied combination table
Indoor Unit
Cassette |
Ceiling Duct |
Outdoor Unit |
|
|
|||
LMNH306TFA0 |
LMNH306BGA0 |
|
|
LMNH306TFC0 |
|
||
|
L8UH1008FA0 |
||
LMNH366TDA0 |
|
||
LMNH366BGA0 |
|
||
LMNH366TDC0 |
|
||
|
|
||
LMNC306TFA0 |
LMNC306BGA0 |
|
|
LMNC306TFC0 |
|
||
|
L8UC1008FA0 |
||
LMNC366TDA0 |
|
||
LMNC366BGA0 |
|
||
LMNC366TDC0 |
|
||
|
|
||
A |
B C D |
|
|
|
|
|
|
|
|
Y connector |
Socket |
Distributor Unit |
P/No: 5211A23319A |
P/No:5162A20011E |
•When piping installation work you must use the Y connector to liquid side piping.
Case 2. Applied combination table
Indoor Unit
Outdoor Unit
Ceiling Duct
LMNC366BGA0 |
L4UC608FA0 |
Short tube connector
P/No :5211A22140A
•When piping installation work you must use the short tube connector to liquid side piping.
P/No.: 3828A30147B
Connection of Piping and Wiring for 30K, 36K Indoor Unit .
PMBD5440L |
Case 1 |
|
|
|
Case 2 |
|
|
|
|||
|
|
Room |
Indoor Unit |
Gas side |
Liquid side |
Wiring |
Room |
Indoor Unit |
Gas side |
Liquid side |
Wiring |
|
|
A |
30K |
use socket |
Y connector |
A |
A |
12K |
normal |
normal |
A |
|
|
B |
- |
- |
No use |
B |
12K |
normal |
normal |
B |
|
|
C D |
|
|||||||||
A B |
C |
12K |
normal |
normal |
C |
C |
30K |
Use socket |
|
C |
|
|
Y connector |
||||||||||
|
|
D |
12K |
normal |
normal |
D |
D |
- |
- |
No use |
|
|
|
|
* 30K Indoor Unit wire must connect 'A' or 'C' room.
Case 1 |
|
|
|
|
Case 2 |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
Room |
Indoor Unit |
Gas side |
Liquid side |
Wiring |
|
Room |
Indoor Unit |
Gas side |
Liquid side |
Wiring |
|
|
|
|
|
|
|
|
|
|
|
A |
30K |
Use socket |
Y connector |
A |
|
A |
30K |
Use socket |
Y connector |
A |
|
|
|
|
|
|
|
|
|
||
B |
- |
- |
No use |
|
B |
- |
- |
No use |
||
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
C |
12K |
normal |
normal |
C |
|
C |
18K |
normal |
normal |
C |
|
|
|
|
|
|
|
|
|
|
|
PMBD5430L |
Case 3 |
|
|
|
Case 4 |
|
|
|
||
|
|
|
|
|
|
|
||||
|
Room |
Indoor Unit |
Gas side |
Liquid side |
Wiring |
Room |
Indoor Unit |
Gas side |
Liquid side |
Wiring |
|
A |
30K |
Use socket |
Y connector |
A |
A |
36K |
Use socket |
Y connector |
A |
|
B |
- |
- |
No use |
B |
- |
- |
No use |
||
A B C |
|
|
||||||||
C |
24K |
Use socket |
normal |
C |
C |
12K |
normal |
normal |
C |
Case 5
Room |
Indoor Unit |
Gas side |
Liquid side |
Wiring |
|
|
|
|
|
|
|
A |
36K |
Use socket |
Y connector |
A |
|
|
|
|
|
||
B |
- |
- |
No use |
||
|
|||||
|
|
|
|
|
|
C |
18K |
normal |
normal |
C |
|
|
|
|
|
|
* 30K, 36K Indoor Unit wire must connect 'A' room
* The Socket converts Pipe size Ø12.7 to Ø15.88.