Thank you very much for your special patronage of LG air-conditioners.
A high-grade, high-quality, advanced individual air-conditioning system that is able to respond to expanding,
more sophisticated housing environment needs.
LG Electronics Inc., which has been a top air conditioner maker for the three consecutive years, has developed
"MPS(Multi Power System) Variable Multi Split" system that can efficiently control air-conditioning in a better
way. Unlike traditional multi-type units, "MPS Variable Multi Split" is a next-generation multi type air-condition-
er designed to be installed under any circumstance.
MPS control provides comfortable and convenient environment as small capacity compressor is operating con-
tinuously compared to conventional ON/OFF cycle compressor. A number of indoor units can be linked to an
outdoor units so that each room can be individually air-conditioned.
This can be easily installed in a small space area, and is energy saving since the cooling of each room individu-
ally controlled.
A lot of information regarding the design and the installation of "MPS Variable Multi Split" system is included in
this publication. We hope that with this information you would become an expert of the "MPS Variable Multi
Split" system and be more comprehensive to the system.
LG Electronics Inc.
Air Conditioning Division
2004 Product Data 1
2MPS Variable Multi Split System(50Hz, R410A)
LG Airconditioners Product Data
TABLE OF CONTENTS
Table of contentsPage
Part 1 Features...............................................................................................7
Part 2 MPS Variable Multi-Split system (R410A).......................................11
2004 Product Data 3
4MPS Variable Multi Split System(50Hz, R410A)
Part 1
Features
2004 Product Data 5
Features & Benefit
Operating Ratio
100%
Cooling Capacity
Power Loss Zone
Cooling
Load
Operating Ratio
100%
Cooling Capacity
Saving Zone
40%
60%
100%
Cooling
Load
35%
Energy Saving
Max.
Conventional (On/Off Operation)MPS
*Condition of trial : ISO5115
100%
40%
60%
Conventional (On/Off Operation)MPS Control
MPS(Multi Power System) Variable Control : (Except A2UC146FA0,A2UH146FA0)
Big Energy Saving with MPS Variable Control
• Basic Principle of MPS Variable Control
MPS control provides comfortable and convenient environment as there are two compressors with 60&40%
load sharing with on compressor of small capacity always working to maintain the set temperature conditions &
meanwhile other compressor is at rest if the load is low whereas in conventional system the only compressor is
working with ON/OFF cycles.
• Power Consumption Comparison
MPS Veriable Multi system opeates in one cycle with two compressors.
Only one compressor or two compressors run together, according to the load conditions.
With small load. only one compressor completes the cycle. It saves power consumption at low operation. This
concept is explained in the picture below.
6MPS Variable Multi Split System(50Hz, R410A)
Features & Benefit
90(Min)
0
100
200
300
400
500
(ppm)
6030
Nano Filter
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Normal Filter
Nasty smell
Deodorizing
Formaldehyde
Deodorizing
V.O.C.
Deodorizing
Composition of Triple Deodorizing Filter
¥ Remove odor !
¥ Restrain mildew !
¥ Keep Performance ! (Durability)
¥ Save time to clean up.
AfterBefore
Effect
In 30 minutes "AutoClean" makes the
inner part of Air
conditioner Dry
After Cooling
Operation, Start "AutoClean" automatically
Air Purifying System
- It not only removes microscopic contaminants & dust, but it
also removes house mites, pollen, and pet fur to help prevent allergic diseases like asthma.It provides odor free, dust
free and allergy free air.
• Effect of carbon Nano Ball
Deodorizing efficieny: 8~10times compared to conventional
carbon filter.
• What is Carbon Nano Ball?
Nano(1/1 Bil) ball structure, (200~500nm) consisted of carbon, is adopted as deodorizing material first in the world.
Triple Deodorizing Filter :
- Deodorizing efficiency
:
10% up compared to conventional Deodorizing Filter
Auto Cleaning System :
- Auto Clean helps to remove odor and save clean-up
time. After using air-conditioner, “Auto Clean” makes the
inner part of Air conditioner dry in 30 min. It removes
moisture and mould so you can enjoy odor-free air and
save time to clean up.
2004 Product Data 7
Features & Benefit
Vertical Temperature
Difference
Horizontal Temperature
Difference
Improved value of the 3-Dimensional Cooling
Time Reaching
Temperature
Thinnest Turbo Fan
129 mm
‘Fast & Even Widely’
Normal
‘Speedy & Powerful’
Jet Cool +
‘Indirectly & Softly’
Sleep Mode
Ultra-Slim design(Depth 129mm)
3-Dimensional Cooling System
New Cube 3-Dimension cooling system of ART COOL has Indirect
Cooling mode for sleep operation.
Being in sleep operation, cool air is discharged only right/left side!
Indirect cooling ensures you nice sleep.
Improved value of the 3-Dimensional Cooling
Vertical Temperature
Difference
Horizontal Temperature
Difference
Air Flow Control (ART COOL)
- In normal mode, 3 Dimensional air flow cools air more fast and even widely
- The bottom-ward air flow provides you with speedy and powerful cooling
- When you sleep, Side air flow provides indirect and soft cooling
Time Reaching
Temperature
8MPS Variable Multi Split System(50Hz, R410A)
Features & Benefit
Environment Friendly Refrigerant :
- LG Air conditioners uses environment friendly refrigerant. Which don't do any harm to the environment.
Jet Cool:
- In this mode very quick and fast cooling is done. The unit will continue to supply high velocity air for 30 min-
utes, untill the room temperature reaches 18°C. After 30 minutes, unit will supply air at the set fan speed
whether indoor temperature has reached 18°C or not.
Self Diagnosis Function:
- This function provides diagnosis of the unit. Blinking of the operation LED of the indoor unit means there is
some error.
Cooling, Heating & Fan Operation:
- LG multi air conditioners can provide cooling, heating & fan operation. In the cooling mode, it cools the air with
an operation range of 18~30°C. In the heating mode, it heats the air with an operation range of 16~30°C. In
the fan operation mode, only indoor fan will run at the selected speed, outdoor fan and compressor will be off.
LCD Wireless Remocon:
- It provides ease of control.
Auto Restart Operation :
- When there is electricity failure the unit sharts off. After resumption of the power, unit will start in the same
mode as prior to the power failure. Memorized condition are on / off condition, operating mode (cooling/heat-
ing), set temperature and fan speed. The unit will memorize the above conditions and start with same memo-
rized condition.
Hot Start Function :
- During starting of the unit in the heating mode it prevents cold air blow from the unit.It starts the indoor fan only
after indoor unit pipe temperature reaches a preset value(28°C). When indoor unit pipe temperature has
reached 28°C, then for initial 1 minute the indoor fan runs at low speed and after that at the set fan speed.
Defrost / Deicing :
- In the heating mode, it prevents the ice formation on the outdoor unit. Sensing the outdoor piping temperature,
If it is lower than some preset value then the outdoor fan stops and compressor continues to run till a particular
temperature is reached. Thereby preventing the frost on the outdoor coil. After reaching a particular high tem-
perature outdoor fan again starts.
Time Delay Safety function:
-It delays restarting of the compressor by three minutes thereby preventing damage to the compressor .
2004 Product Data 9
10MPS Variable Multi Split System(50Hz, R410A)
Part 2
MPS Variable Multi-Split System
R410A, Cooling Only/Heat Pump
AMNC076LQL0 AMNC096AP*1
AMNC096LQL0 AMNC126AP*1
AMNC126LRL0
AMNC186LTL0
AMNC246LTL0
AMNH076LQL0 AMNH096AP*1
AMNH096LQL0 AMNH126AP*1
AMNH126LRL0
AMNH186LTL0
AMNH246LTL0
1. Power Supply .................................................................................................................12
2. Model Number Nomenclature .......................................................................................13
3. Outline of System...........................................................................................................14
4. List of Functions .............................................................................................................16
- The power supply is needed only to the outdoor unit. The power supply to the indoor unit Is conducted
through the transmission wiring. Therefore, the power supply can be given at just one place. It will contribute
to simplify the work procedure and to save cost.
A2UC186FA0
A3UC216FA0
A4UC306FA0
A2UH146FA0
A2UH186FA0
A3UH216FA0
A4UH306FA0
1Ø, 220~240V, 50Hz
12MPS Variable Multi Split System(50Hz, R410A)
2. Model Number Nomenclature
AMNH6
07
QLL0
Chassis Name
Serial Number
Combination of Functions
ART COOL Type Front Panel Color
L : Wall Mounted A : ART COOL
B : Blue, D : Wood, M : Metal
L : Nano Plasma
Indoor Unit Type
Electrical Ratings
6: 1ø, 220~240V, 50Hz
Nominal Cooling Capacity in Btu/h
Ex) 7,000 Btu/h ➞ ‘07’ , 18,000 Btu/h ➞‘18’
Model Type
C: Cooling Only H: Heat Pump
Multi Split System Indoor Unit
A3UH621FA0
Multi Type
F: Free Joint Multi Type
Function
A: Basic
Serial Number
Electrical Ratings
6: 1ø, 220~240V, 50Hz
Nominal Cooling Capacity in Btu/h
Ex) 21,000 Btu/h '21', 30,000 Btu/h ➞'30' ➞
Model Type
C: Cooling Only H: Heat Pump
R410A Multi Split System Outdoor Unit
And No. of Connectable Indoor Units
Ex) A3U : Connectable 3 Indoor Units
A4U : Connectable 4 Indoor Units
2.1 Indoor Units
2.2 Outdoor Units
2004 Product Data 13
3. Outline of System
The system has number of indoor units attached to an outdoor unit which saves energy while in operation.
This system can be installed in small space and cooling can be controlled in each room individually.
3.1 Example of System
[A4UH306FA0]
3.2 Combination of Indoor and Outdoor Unit
Indoor Units
A2UC146FA0
A2UH146FA0
2234
Model
Type
Wall
Mounted
ART COOL
Capacity
IndexkWBtu/h
72.17000OOOO
92.69000-OOO
123.512000-OOO
185.318000---O
247.024000---O
92.69000-OOO
123.512000-OOO
Outdoor Unit
A2UC186FA0
A2UH186FA0
No. of Connectable Indoor Units
A3UC216FA0
A3UH216FA0
A4UC306FA0
A4UH306FA0
14MPS Variable Multi Split System(50Hz, R410A)
3. Outline of System
3.3 External Appearance of Indoor Units
Wall Mounted
AMNC076LQL0 AMNH076LQL0
AMNC096LQL0 AMNH096LQL0
AMNC126LRL0 AMNH126LRL0
AMNC186LTL0 AMNH186LTL0
AMNC246LTL0 AMNH246LTL0
ART COOL
AMNC096AP*1 AMNH096AP*1
AMNC126AP*1 AMNH126AP*1
'* : Front Panel Color
B : Blue
D : Wood
M : Metal
2004 Product Data 15
4. List of Functions
Features
Model
Airflow Direction Control(Left & Right)ManualManualManualManual
Airflow Direction Control(Up & Down)AutomaticAutomaticAutomaticAutomatic
Airflow Outlet1313
Airflow Steps(Fan / Cool / Heat)3/4/33/4/33/4/33/4/3
Auto Changeover(Operation)---Auto Cleaning-O-O
Auto Restart OperationOOOO
Central ControlAccessoryAccessoryAccessoryAccessory
CHAOS Wind(Auto Wind)OOOO
Child Lock Function---Cooling & Heating Fan OperationO(not heating)O(not heating)OO
Deice Control--OO
Deodorizing FilterO(Triple)-O(Triple)Drain Pump---E.S.P Control---Forced OperationOOOO
Group Control---High Ceiling Operation---Hot Start Function--OO
Jet CoolOOOO
Nano Plasma Air Purifying FilterOOOO
Plasma Heat Exchanger---Prefilter(Washable / Anti-fungus)OOOO
Self Diagnosis FunctionOOOO
Sleep Mode OperationOOOO
Soft Dry OperationOOOO
Soft Start Function---Test FunctionOOOO
Time Delay Safety FunctionOOOO
Timer(24 Hour, On/Off)OOOO
Timer(Weekly, On/Off)---Two Thermistor Control---Wired LCD Remote Control---Wireless LCD Remote ControlOOOO
Zero Stanby Power---Zone Control----
AMNC-LQ/LR/LTAMNC-APAMNH-LQ/LR/LTAMNH-AP
Notes :
O : Basic
Optional : Factory-Installed
Accessory : Field-Installed
- : Not available on this system
16MPS Variable Multi Split System(50Hz, R410A)
5. Specifications
5.1 Indoor Units
Cooling Only
Indoor Unit Type
Model
Nominal Cooling Capacity ★kcal/hr(W)
Nominal Heating Capacity ★kcal/hr(W)
Air Circulation H/M/L
Setting temperature range°C
Fan motorOutputW
FanType
Fan RPMCooling(H/M/L)rpm
Noise Level
(Sound Press,1m)
Temperature controller
CoilTube Size (OD)inch(mm)
Dehumidification Ratel/h
Dimensions (W*H*D)inch(mm)
Net Weightkg(lbs)
Piping Liquidinch(mm)
ConnectionGasinch(mm)
2. Due to our policy of innovation some specifications may be changed without notification.
18MPS Variable Multi Split System(50Hz, R410A)
5. Specifications
5.2 Outdoor Units
Cooling Only
Cooling Capacity ★kcal/hr
Heating Capacity ★kcal/hr
Input ★Cooling/HeatingW
Running Current ★Cooling/HeatingA
Starting CurrentCooling/HeatingA
Power SupplyØ,V,Hz
Power Factor%
Compressor ALocked Rotor Amp.A
Compressor BLocked Rotor Amp.A
RefrigerantChargeg(oz), type
CoilTube Size (OD)inch(mm)
Fan MotorOutputW
FanType
Air Circulation CMM(CFM)
Noise Level(Sound Press,1m)dBA
Piping ConnectionLiquidinch(mm)
Dimensions (W*H*D)inch(mm)
Net Weightkg(lbs)
Power Supply CableNo.* mm
Interunit CableNo.* mm
Max. Interunit Piping Length
Input ★Cooling/HeatingW
Running Current ★Cooling/HeatingA
Starting CurrentCooling/HeatingA
Power SupplyØ,V,Hz
Power Factor%
Compressor ALocked Rotor Amp.A
Compressor BLocked Rotor Amp.A
RefrigerantChargeg(oz), type
CoilTube Size (OD)inch(mm)
Fan MotorOutputW
FanType
Air Circulation CMM(CFM)
Noise Level(Sound Press,1m)dBA
Piping ConnectionLiquidinch(mm)
Dimensions (W*H*D)inch(mm)
Net Weightkg(lbs)
Power Supply CableNo.* mm
Interunit CableNo.* mm
Max. Interunit Piping Length