LG LG340Q1C-A5, LG360Q1C-A5, LG350Q1C-A5, LG355Q1C-A5, LG365Q1C-A5 Installation Manual

...
Please read this manual carefully before operating your set and retain it for future reference
www.lg-solar.com
Installation manual
PV Solar MODULE
P/NO : MFL69724902 (Rev 00)
LGXXXQ1C(K)-A5
Table of Contents
CONTENTS
1. Safety 3
2. Before & After Installation 4
3. Electrical Installation 5
4. Mechanical Installation 6
5. Product Specifications 8
6. Disclaimer of Liability / Disposal 10
7. Transporting and Storage 10
8. Appendix. 11
Revisions Table
Date Version Description of change Remark
2016.09.02 1.0 (1stedition)
2016.12.07 2.0
Add New Products(Black Model)
2
Safety
3
The instructions related to the safety indicated in the following are for preventing unexpected danger or damage in advance by safely and exactly using the product.
Non-compliance of the instructions may immedia­tely cause serious injury or death.
Non-compliance of the instructions may cause death or serious injury to the user.
Non-compliance of the instructions may cause injury or property damage to the user.
Do not contact with electrically active parts of
the panel, such as terminals, regardless of connection of the module. It may result in spark or lethal electric shock.
Please don’t use the module with the broken
window or the torn back side. There is a danger of electric shock.
Please perform works in the dry condition and
use only dry tools. Do not handle the wet panels without protection equipment. It may result in safety accident.
Damaged module must be treated with safety
protection equipment. It may result in injury.
Do not approach the damaged or broken module
unless you are an expert. It may result in serious injury.
No electrical parts like cables are located after
installation between laminate and mounting structure.
Do Not reconnect or repair Junction box Cable.
It may occur spark or electric shock. Do not bending junction box's cable. While under stress, it may occur module damage. Cable bending radius should be more than 4 times the cable diameter, at least.
Please use proper equipment, connector, wire
and buttress for system configuration of the module. It may result in damage or failure of the product.
Do not perform installation in rainy, heavily
windy or snowy days. It may result in safety accident.
Do not make holes in the frame or glass of the
module. It may decrease the strength of the frame or break the glass.
Do not touch the glass surface or frame of the
solar module after installation of the module. It may result in injury.
Do not locate a heavy object onto the module.
Do not stand on or step on the module. Do not drop or suddenly lay down the module. It may result in injury.
Do not scratch the coating surface of the frame.
It may decrease the strength due to corrosion of the frame.
Do not concentrate sunlight on the module
surface. It may result in damage of the product.
Do not apply a shock to the junction box of the
module or pull the cable. Do not remove the labels attached to the module. It may result in damage of the product.
If the installing structure has a curved surface
e.g. arch type as shown in the below picture, do not forcefully modify the module in installation when connecting it with the structure. Please install the module in the place where the structure has been completely set up because deformation of the structure may cause deformation of the product when performing installation by using a crane, etc after assembling the module to the installing structure.
Before & A fter Installation
Before Installation
Please carefully read this manual before installation.
• Solar module installation should be performed by
an authorized installer for the safety and
maintenance of the system.
• All installation instructions should be clearly
understood before attempting installation.
• Do not twist, pull, or scratch the cable attached to
the solar module.
• Do not touch the solar module with bare hands. It
may result in a burn or injury.
• Do not drop the solar module and cause an
excessive load on solar module.
• Do not disassemble the solar module.
• After installation or repair, check whether solar
module operates properly or not.
• In case the currently used solar module or the
parts applied to the solar module have been
replaced, check whether the changed solar
module is properly operated or not. The newly
replaced solar module and its parts must be the
same solar module(module name) and parts with
the current solar module.
• Please contact the local office to confirm the
regulations and to obtain permission.
• Do not let anyone approach the solar module
who has little knowledge of solar modules or on
the measures to take
when solar modules are damaged in order to avoid the risk of injury or electrical shock.
• Do not locate the solar module horizontally, as this may cause dirt or white efflorescence (glass deformation)
• Panels produce voltage even when not connected to an electrical circuit or load.
• Panels are intended for outdoors, land based applications only. Panels are not intended for use indoor use or application on moving vehicles of any kind.
• Reflection from external environments such as snow, water or other surfaces can increase the power generated by the panel.
• Industry standard rated specifications are made at conditions of 1000W/m
2
irradiance and 25°C (77ºF) solar cell temperature. Colder temperatur­es can substantially increase voltage and power.
• Keep the solar module and system away from children when installing.
• Keep the module packed in the carton until the time of installation.
• Make sure flammable gases are not generated near the installation site.
• Do not work alone. Please work as part of a team of two or more people.
• Wear a safety belt if working high above the ground.
• Contact with electrically active parts of the panels, such as terminals, can result in burns, sparks and lethal shock whether the panel is connected or disconnected.
• Even partial shadowing can substantially reduce panel and system output.
• Care must be taken to avoid low tilt angles which may cause dirt to buildup on the glass against the frame edge.
• Dirt build-up on the surface of the panel can cause active solar cells to be shaded and electrical performance to be impaired.
• Always keep the back surface of the panel free from any foreign objects or structural elements which could come into contact with the panel, especially when the panel is under mechanical load.
• For permission to use mounting methods not described in the Mounting Guide please consult LG Solar. Failure to do so will void the warranty and panel certification.
After Installation
Plug the connector in tightly and ensure that the wiring properly works.
• It is advisable to conduct periodic inspection of the panels for damage to front glass, back sheet, frame, junction box, or external
electrical
connections.
• Check electrical connections for loose connec­tions and corrosion.
• PV panels can operate effectively without ever being washed, although removal of dirt from the front glass can increase output.
• Water, ethanol or a conventional glass cleanser with a micro-fiber cloth can be used for regular washing or rinsing of the front glass to remove dust, dirt or other deposits.
• No aggressive and abrasive cleansers or chemicals such as alkali chemicals including ammonia based solution should ever be used on the treated front glass.
• Always wear rubber gloves for electrical insulation while maintaining, washing or cleaning panels.
• Deposits of foreign material on the frame surface can be cleaned using a wet sponge or cloth and dried in air or by using a clean chamois.
• Perform the wiring work by connecting the connector and wires to the stand away from the roof or ground.
4
Loading...