3" (7.6 cm)
24"
(60.9 cm)
24"
(60.9 cm)
15" (38 cm)
11" (28 cm)
2.5" (6.3 cm)
2.5"
(6.3 cm)
9"
(23 cm)
4"
(10 cm)
9"
(23 cm)
4"
(10 cm)
6"
(15.2 cm)
5"
(13 cm)
6"
(15.2 cm)
25"
(63.5 cm)
36"
(91.4 cm)
3" (7.6 cm)
Acceptable
electrical
outlet area
Normal counter
top depth
Counter
top height
Cabinet
opening
Wall
Center
Cabinet
30"
(76.2 cm)
36"
(91.4 cm)
**15"
(38.1 cm)
*30" (76.2 cm)
Minimum
MINIMUM DIMENSIONS
* 30” (76.2 cm) minimum clearance
between the top of the cooking
surface and the bottom of an
unprotected wood or metal cabinet;
or 24” (60.9 cm) minimum when
bottom of wood or metal cabinet
is protected by not less than
1/4”(6.4 cm) ame retardant
millboard covered with not less than
no. 28 MSG sheet steel, 0.015”
(0.381 mm) stainless steel, 0.024”
(0.610 mm) aluminum or 0.020”
(0.508mm) copper.
** 15” (38.1 cm) minimum
between countertop and
adjacent cabinet bottom.
3" (7.6 cm)
24"
(60.9 cm)
24"
(60.9 cm)
36"
29.8"
(75.7 cm)
15" (38 cm)
11" (28 cm)
2.5" (6.3 cm)
2.5"
(6.3 cm)
9"
(23 cm)
4"
(10 cm)
9"
(23 cm)
4"
(10 cm)
6"
(15.2 cm)
5"
(13 cm)
6"
(15.2 cm)
25"
(63.5 cm)
36"
(91.4 cm)
3" (7.6 cm)
Acceptable
electrical
outlet area
Normal counter
top depth
Counter
top height
Cabinet
opening
Wall
Center
Cabinet
A = 30" (76.2 cm)
DIMENSIONS AND CLEARANCES
This appliance must be installed and
grounded on a branch circuit by a qualied
technician in accordance with the National
Electrical code ANSI/NFPA NO. 70 - latest
edition.
All wiring should conform to Local and NEC
codes. This range requires a single-phase, 3
wire, A.C 120/208 V or 120/240 V 60 Hz
electrical system. Use only a 3-conductor or
a 4-conductor UL - listed range cord with
closed-loop terminals, open-end spade lugs
with upturned ends or similar termination.
Do not install the power cord without a
strain relief.
A range cord rated at 40 amps with
120/240 minimum volt range is required.
If a 50 amp range cord is used, it should
be marked for use with 13/8" diameter
connection openings. This appliance may
be connected by means of a conduit or
power cord. If a conduit is being used, check
the Owners Manual for 3 wire conduit
connections or 4 wire conduit connections.
▲
! Warning
• Allow 2 to 3 ft (61.0 cm to 91.4 cm) of
slack in the line so that the range can be
moved if servicing is ever necessary.
• The power supply cord and plug should
not be modied. If it will not t the
outlet, have a proper outlet Installed by
a qualied electrician.
• Using an extension cord to connect the
power is prohibited. Connect the power
cord and plug directly.
• Electrical ground is required on this
appliance.
• Make sure that the power cord is not
pinched by the range or heavy objects.
Failure to do so can result in serious
burns or electrical shock.
Specified power-supply-cord kit rating
Range rating, watts
Specified
rating of
power
supply-
cord kit,
amperes
Diameter (inches)
of Range
connection
Opening
120/240
volts
3-wire
120/208
volts
3-wire
Power
cord
Conduit
8,750 16,500
16,501 22,500
7,801 12,500
12,501 18,500
40 or 50A
50
1
3
/8"
1
3
/4"
1
1
/8"
1
3
/8"
4 Wire
receptacle
(14-50R)
3 Wire
receptacle
(10-50R)
ELECTRICAL REQUIREMENTS
LDE4413*
QUICK INSTALL &
CLEARANCES
For full installation directions/clearances
please refer to the corresponding
User Manual and Installation Guide.
DIMENSIONS/CLEARANCES/WEIGHT
Shipping Weight 215 lbs
Product Weight 191.8 lbs
Cabinet Width (in) 30"
Overall Depth (in) - including handle 28-15/16"
Overall Height (in) - including backguard 47-9/32"
Overall Width (in) 29-15/16"
Upper Oven
Interior Dimensions (in) 24-13/16" x 10-13/16" x 19-13/16"
(W x H x D)
Height to Cooking Surface (in) 36"
Lower Oven
Interior Dimensions (in) 24-13/16" x 14-1/4" x 19-15/16"
(W x H x D)
Carton Dimensions (in)
(W x H x D) 31-31/32” x 51” x 30-17/32”
POWER/RATINGS
Amp Rating at 208V 40A
Amp Rating at 240V 40A
KW Rating at 208V 11.6kW
KW Rating at 240V 15.5kW
LG Brand_Electric Ranges Fin_1.indd 4 8/21/17 4:22 PM