LG Art Cool Mirror Inverter, LAU090HSV2, LAU120HSV2, LAN090HSV2, LAN120HSV2 Engineering Manual

...
ART COOL MIRROR INVERTER WALL MOUNTED
ENGINEERING MANUAL
Art Cool Mirror Inverter Wall Mounted
3/4 Ton,1 Ton, 1 1/2 Ton and 2 Ton
This document, as well as all reports, illustrations, data, information, and
other materials is the property of LG Electronics U.S.A., Inc., and are
disclosed by LG Electronics U.S.A., Inc., only in confidence.
This document is for design purposes only.
DFS-EM-AA-001-US_014B06
For continual product development, LG Electronics U.S.A., Inc., reserves the right to change specifications without notice.
©LG Electronics U.S.A., Inc.
About LG Electronics, Inc.
LG Electronics, Inc. is a global leader and technology innovator in consumer electronics, mobile communications, and home appliances, employing more than 213,000 people in more than 60 countries worldwide. With $136 billion (USD) revenue in 2011, LG Electronics, Inc. is ranked among Fortune 500’s list of largest companies. LG Electronics, Inc. comprises five business units— Home Entertainment, Mobile Communications, Air Conditioning, Business Solutions, and Home Appliance. LG is one of the world’s leading producers of flat panel televisions, audio and video products, mobile handsets, air conditioners, and washing machines. LG’s commercial air conditioning business unit was established in 1968 and has built its lineup of residential and commercial products to include VRF, Flex-Multi, duct-free split systems, packaged terminal air conditioners (PTACs), and room air conditioners. In 2011, the air conditioning and energy solutions business unit grew to include LED lighting and solar products. For more information, visit www.lg.com.
Duct-Free Split (DFS) Systems
LG HVAC systems offer a range of solutions that are cost efficient, quiet and attractive. Duct-Free Split (DFS) systems are “split” into indoor and outdoor units, and provide a smart alternative to both central HVAC and window-mounted air conditioners. These inverter
heat pump systems are available in a variety of configurations to suit
different cooling and heating situations. Installation by a qualified HVAC contractor is safe and easy – little to no duct work or sheet metal is required.
Inverter Systems
LG Single Zone Inverter Wall Mount air-source systems offer the opportunity to minimize ductwork in the same configuration. The system offers zoning without the need for zone damper systems. The LG Single Zone Inverter Wall Mount system’s advanced controls provide exceptional building dehumidification and temperature control, and can rapidly adapt system operating parameters to the ever changing building load. The LG Single Zone Inverter Wall Mount system is easy to design, install, and maintain. The modular design allows occupants to control their environmental condition, providing individualized control of the set-point temperature and allowing oc­cupants to condition only the occupied zones.
Quality Commitment
LG is committed to the success of DFS projects. We provide industry leading technical support during installation and commissioning. LG
offers a variety of classes designed for installers and servicers to ensure that every DFS system installation is completed successfully. Classes are conducted at LG’s training centers and in field locations at various times throughout the year and upon special request.
Introduction
Due to our policy of continuous product innovation, some specications may change without notication.
3
TABLE OF CONTENTS
INTRODUCTION ..................................................................................... 5
Architectural Appeal.............................................................................. 6
PRODUCT FEATURES AND BENEFITS ............................................... 8
UNIT NOMENCLATURE .........................................................................9
General Data ................................................................................... 10-13
General Data and Electrical Data ....................................................... 14
Outdoor Unit Dimensions ................................................................... 15
LAU090HSV2, LAU120HSV2 ............................................................ 15
LAU180HSV2, LAU240HSV2 ............................................................ 16
Indoor Unit Dimensions ...................................................................... 17
LAN090HSV2, LAN120HSV2 ............................................................ 17
LAN180HSV2, LAN240HSV2 ............................................................ 18
ACOUSTIC DATA .................................................................................19
Refrigerant Flow Diagrams ................................................................. 20
LAN090HSV2, LAU090HSV2
LAN120HSV2, LAU120HSV2 ............................................................20
LAN180HSV2, LAU180HSV2 ............................................................ 21
LAN240HSV2 LAU240HSV2 ............................................................. 21
Wiring Diagram .................................................................................... 22
LAN090HSV2, LAN120HSV2 ............................................................ 22
LAN180HSV2, LAN240HSV2 ............................................................ 23
LAU090HSV2, LAU120HSV2 ............................................................ 24
LAU180HSV2, LAU240HSV2 ............................................................ 25
Accessories ......................................................................................... 26
PERFORMANCE DATA ........................................................................ 33
Cooling Capacity ............................................................................... 33
Heating Capacity ............................................................................... 35
Equipment Selection Procedure ........................................................ 39
LAN090HSV2, LAU090HSV2
LAN120HSV2, LAU120HSV2 ............................................................39
LAN180HSV2, LAU180HSV2
LAN240HSV2, LAU240HSV2 ............................................................ 40
Building Ventilation Design Guide ..................................................... 41
Placement Considerations ............................................................ 43-45
REFRIGERANT PIPING DESIGN & LAYOUT
BEST PRACTICES ...............................................................................46
Refrigerant Piping Design .................................................................. 47
Design Guideline Summary ............................................................... 47
Selecting Field-Supplied Copper Tubing ........................................... 48
Installation & Layout Best Practices ................................................. 49
Refrigerant Piping System Layout ..................................................... 49
Piping Connection ............................................................................. 52
ELECTRICAL CONNECTIONS ............................................................54
Mechanical Specications .................................................................. 55
Acronyms ............................................................................................. 56
Art Cool Mirror Wall Mounted Engineering Manual
TABLE OF SYMBOLS
This symbol indicates a potentially hazardous situation which, if not avoided, may result in death or serious injury.
This symbol indicates additional helpful information such as an explanation, a comment, or a clarication
about the subject.
This symbol indicates a recommendation or tip. Recommendations instruct the user to apply the suggested
practice to ensure the best operating results in order to achieve the maximum benet of the product. Tips
contain practical information that may help the user solve a problem or describe actions that may save time.
4
Due to our policy of continuous product innovation, some specications may change without notication.
INTRODUCTION
“Architectural Appeal” on page 6
ARCHITECTURAL APPEAL
Convergence of Technological Innovation with Flexibility and Style
Single Zone Inverter
Benefits of Single Zone
Art Cool Mirror Wall Mount Split
•Inverter technology
•Available in 9,000, 12,000, 18,000 and 24,000
Btu/h capacities
•All-season use - heat pump models for both cooling and heating capabilities
•Operating ranges for Outdoor units of 14°F (DB) to 118°F for cooling; 5°F to 75°F (WB) for heating
•Operating ranges for Indoor Units of 64°F to 90°F for cooling; 60°F to 86°F for heating
Wall Mount
The Single Zone Art Cool Mirror Wall Mount Duct Free Split (DFS) System is among the industry’s best air-condition­ing units. Choosing an LG Single Zone Wall Mount product provides a system designer an edge to engineer a system with individual control, and design flex­ibility with advanced controls. The Art Cool Mirror Outdoor and Indoor units are available in a nominal capacity range of 3/4 ,1, 1 1/2 and 2 tons. These are best suited for applications with zones that require heating or cooling, such as residential, and small business office buildings.
Single Zone Wall Mount Outdoor and Indoor units are available in 208–230V/60Hz/1Ph.
•Quiet operation inside and outside
•Duct Free Split system
Art Cool Mirror Wall Mounted Engineering Manual
Adaptable and Flexible
The Single Zone Wall Mount DFS System allows cooling or heating for the entire residence or just a single room without the need for evasive ductwork. There is no tearing down of walls or altering the homes appearance.
Long refrigerant piping lengths allow for extra design flexibility in indoor unit installation.
These units may be used for a number of residential or commercial environments such as:
•Older homes
•New home construction
•Office buildings
•Restaurants
•Hospitals / Medical facilities
•Schools
•Nursing homes
•Retail establishments
•House of worship
Inverter Technology
Inverter variable-speed DFS Systems are measurably quieter and consume less energy than conventional air conditioners. The Inverter compressor ramps up or down to match the required room capacity and maintain the comfort level. When the selected temperature is reached, the inverter compressor operates at low speed to maintain that comfort level, thereby using less energy.
6 | INTRODUCTION
Due to our policy of continuous product innovation, some specications may change without notication.
PRODUCT DATA
“Product Features and Benefits” on page 8
“Unit Nomenclature” on page 9
“General Data” on page 10
“Electrical Data” on page 7
“Outdoor Unit Dimensions” on page 15
“Indoor Unit Dimensions” on page 18
“Acoustic Data” on page 7
“Refrigerant Flow Diagram” on page 16
“Indoor Unit Wiring Diagram” on page 22
“Outdoor Unit Wiring Diagram” on page 23
“Accessories” on page 26
PRODUCT FEATURES AND BENEFITS
Single Zone Art Cool Mirror Wall Mount
Single Zone Art Cool Mirror Wall Mount units are equipped with inverter components that offer superior load matching and long piping installation. The product works for optimizing power consumption in residential and small office buildings. Utilizing multiple indoor wall mount units each with custom temperature controls allow for precise temperature settings in each zone of the building. Art Cool Mirror allows flexibility in interior design and complements any decor.
Low Sound Levels
When outdoor units operate fully loaded, they have one of the quietest sound levels in the industry. Sound is almost undetect­able during off-peak operation. To promote a quiet, comfortable environment, the LG Single Zone Art Cool Mirror indoor units op­erate at sound levels as low as 24 dB(A) and outdoor units as low as 45 dB(A) at full load. LG customers often ask if the outdoor unit is running after commissioning is complete.
All rotating components are soft-started by the controller using digitally controlled inverters, which reduce undesirable noise caused by fans and compressors cycling on and off.
Comfort Control at Its Best
Tight temperature control through precise load matching maximizes the time that the indoor units remove moisture.
Unlike traditional air conditioning control systems, which use thermostatic controls
Art Cool Mirror Wall Mounted Engineering Manual
to maintain room temperatures, LG Single Zone Inverter controls continuously vary the indoor unit fan speed and refrigerant flow, in­directly providing lower and more consistent humidity levels in the conditioned space. The longer the indoor coil temperature is below the dew-point of the room in conjunction with air movement across the coil, the space humidity level will vary little, compared to technologies that cycle fans and compressors on and off multiple times per hour.
The outdoor unit responds by varying the compressor speed and outdoor fan motors as needed to maintain system operating pressure. As a result, the Single Zone Art
Cool Mirror Wall Mount system delivers precise space temperature control.
Inverter Driven
The rotary (9k/12k Btu/h systems) and twin­rotary (18k/24k Btu/h systems) compressor is optimized to maximize compressor ef­ficiency, which reduces power consumption and monthly utility bills. This latest inverter technology allows the LG Single Zone Art Cool Mirror Wall Mount outdoor unit to vary the compressor motor shaft speed to deliver an appropriate amount of cooling to the indoor unit. Precise refrigerant volume delivery translates into long periods with coil surface temperatures below dew point and minimizes compressor and fan component run time. Occupants remain comfortable while utility costs are reduced.
Simplified Installation
Cooling and heating systems that use the LG Single Zone Art Cool Mirror Wall Mount product simplify and reduce the mechani­cal and control system design time. The designer no longer has to be concerned with interconnecting chilled and condenser water piping, air-distribution duct systems, matching and selecting chillers, towers, pumps, coils, fans, air handlers, or Variable Air Volume (VAV) boxes.
Operating Range
The Single Zone Art Cool Mirror Wall Mount product has a nominal capacity range of 3/4, 1, 1 1/2 and 2 tons (depending on outdoor/ indoor units). Operating ranges include:
Art Cool Mirror Outdoor Units
Cooling: 14°F DB to 118°F DB Heating: 5°F WB to 75°F WB
Compact Size
Single Zone Art Cool Mirror Wall Mount out­door units have the following footprints.
LAU090HSV2, LAU120HSV2
(WxHxD (in.)): 30 5/16 x 21 1/2 x 11 5/16
LAU180HSV2, LAU240HSV2
(WxHxD (in.)): 34 1/4 x 31 1/2 x 12 19/32
Heat Transfer Efficiency
Fin Design with GoldFin™ Coating
All Single Zone Art Cool Mirror Wall Mount out­door units are provided with large surface coils made of copper tubes with louvered aluminum
nsdesignedtomaximizeunitoperatingef­ciencyoverawiderangeofambientconditions.
Standard from the factory, every LG Single Zone Art Cool Mirror Wall Mount outdoor coil fin surface is coated with LG’s exclusive GoldFin™ anti-corrosive coating designed to prevent natural surface corrosion of the aluminum fins. This maintains heat transfer properties of the coil for an extended time.
A hydrophilic coating is applied to the outdoor unit coil fin surface over the GoldFin coating. This coating enhances the develop­ment of heavier water droplets gathering on the fin surface. As a result, the droplets roll off the fin surfaces, delaying the point when frost forms on the coil surface during heat­ing operation. This coating also makes it possible to easily clean the outdoor unit coil using a mild soap.
Other Features
•Inverter Variable Speed Compressor
•Jet Cool/Jet Heat
•Dehumidifying Mode
•Plasma filter
•Chaos Wind
•Auto restart
•Auto operation
•Self-cleaning indoor coil
•Smaller Footprint
•Precision Load Matching
•Meets AHRI 210/240
8 | PRODUCT DATA
Due to our policy of continuous product innovation, some specications may change without notication.
UNIT NOMENCLATURE
Single Zone Wall Mount Indoor and Outdoor Units
Family LA= Art Cool Premier/ Gallery / Mirror LS= High Efficiency Wall Mount / Standard/ Mega
Type N = Indoor Wall Mount Unit U = Outdoor Heat Pump Unit
Nominal Capacity (Nominal cooling capacity in Btu/h)
090/091 = 9,000 120/121 = 12,000 180/181 = 18,000 240 = 24,000 307 = 30,000 360 = 36,000
Indoor/Outdoor Product HEV = Mega HYV = Art Cool Premier HVP = Art Cool Gallery HSV = High Efficiency HSV2 = Art Cool Mirror HV = Standard
Generation 2 = Second 3 = Third
LA
N 090 HSV 2
Product Data
Due to our policy of continuous product innovation, some specications may change without notication.
PRODUCT DATA | 9
GENERAL DATA
Art Cool Mirror Pairing Table
The following table shows the available outdoor and indoor units, along with the factory provided controller.
Table 1: Single Zone Art Cool Mirror Pairing Table
Outdoor Unit Model/ Btu/h Indoor Unit Model/ Btu/h Controller
LAU090HSV2 / 9,000
LAU120HSV2 / 12,000
LAN090HSV2 / 9,000
LAN120HSV2 / 12,000
AKB73635606
LAU180HSV2 / 18,000
LAU240HSV2/ 24,000
Art Cool Mirror Wall Mounted Engineering Manual
LAN180HSV2 / 18,000 LAN240HSV2 / 24,000
AKB73635606
10 | PRODUCT DATA
Due to our policy of continuous product innovation, some specications may change without notication.
GENERAL DATA
Art Cool Mirror Inverter Specications
Table 2: Unit General Data
Type Art Cool Mirror
System (Model) LA090HSV2 (LAN090HSV2/LAU090HSV2) LA120HSV2 (LAN120HSV2/LAU120HSV2) Nominal Cooling Capacity (Btu/h) 9,000 11,200 Cooling Power Input Nominal Heating Capacity (Btu/h) 10,800 13,300 Heating Power Input1 (kW) 0.70 1.00
Cooling COP 3.90 3.66 EER 13.3 12.5 SEER 20 HSPF 11 Power Supply (V / Hz / Ø) 208-230/60/1
ODU Operating Range
Cooling (°F DB) 14-118 Heating (°F WB) 5-75
IDU Operating Range
Cooling (°F WB) 64-90 Heating (°F DB) 60-86
Indoor Temperature Setting Range
Cooling (°F) 65-86 Heating (°F) 61-86
Unit Data
Refrigerant Type Refrigerant Control EEV IDU Sound Pressure ODU Sound Pressure dB(A) 45
Unit Weight (lbs)
Indoor Unit (Net/Shipping) 25/30 Outdoor Unit (Net/Shipping) 78/82 Power/Communication Cable4 (No. x AWG) 4 x 18
Fan
Indoor Type (Qty) Cross Flow (1) Outdoor Type (Qty) Propeller (1) Motor/Drive Brushless Digitally Controlled/Direct
Airflow Rate
Indoor - H/M/L (CFM) 335/272/212 Outdoor - Max (CFM) 1,165
EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit Power wiring is field supplied and must comply with the applicable local and national codes. This unit comes with a dry helium charge. This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units. Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
1
(kW) 0.68 0.90
2
R410A
3
dB(A) (H/M/L) 38/33/24 39/33/24
1
Power Input is rated at high speed.
2
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA.
3
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
4
All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must comply with applicable and national code.
353/272/212
Product Data
Due to our policy of continuous product innovation, some specications may change without notication.
PRODUCT DATA | 11
GENERAL DATA
LAU090HSV2, LAU120HSV2
Table 2: Unit General Data (Continued)
Type Art Cool Mirror
System (Model) LA090HSV2 (LAN090HSV2/LAU090HSV2) LA120HSV2 (LAN120HSV2/LAU120HSV2)
Piping
Liquid Line (in, OD) 1/4 Vapor Line (in, OD) 3/8 Condensation Line (OD | ID) 27/32 | 5/8 Additional Refrigerant Charge (oz/ft) 0.22 Max Pipe Length (ft) Piping Length (no add’l refrigerant, ft) Max Elevation Difference (ft) 32.8
EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit Power wiring is field supplied and must comply with the applicable local and national codes. This unit comes with a dry helium charge. This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units.
5
5
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
5
Piping lengths are equivalent.
65.6 41
Art Cool Mirror Wall Mounted Engineering Manual
12 | PRODUCT DATA
Due to our policy of continuous product innovation, some specications may change without notication.
GENERAL DATA
Art Cool Mirror Inverter Specications
Table 2: Unit General Data (Continued)
Type Art Cool Mirror
System (Model) LA180HSV2 (LAN180HSV2/LAU180HSV2) LA240HSV2 (LAN240HSV2/LAU240HSV2) Nominal Cooling Capacity (Btu/h) 18,200 22,000 Cooling Power Input Nominal Heating Capacity (Btu/h) 22,000 27,600 Heating Power Input1 (kW) 1.76 2.67
Cooling COP 3.69 3.16 EER 12.6 10.8 SEER 20.5 20 HSPF 9.7 10 Power Supply (V / Hz / Ø) 208-230/60/1
ODU Operating Range
Cooling (°F DB) 14-118 Heating (°F WB) 5-75
IDU Operating Range
Cooling (°F WB) 64-90 Heating (°F DB) 60-86
Indoor Temperature Setting Range
Cooling (°F) 65-86 Heating (°F) 61-86
Unit Data
Refrigerant Type Refrigerant Control EEV IDU Sound Pressure ODU Sound Pressure dB(A) 53
Unit Weight (lbs)
Indoor Unit (Net/Shipping) 38/42 Outdoor Unit (Net/Shipping) 133/142 Power/Communication Cable4 (No. x AWG) 4 x 18
Fan
Indoor Type (Qty) Cross Flow (1) Outdoor Type (Qty) Propeller (1) Motor/Drive Brushless Digitally Controlled/Direct
Airflow Rate
Indoor - H/M/L (CFM) Outdoor - Max (CFM) 2,119
EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit Power wiring is field supplied and must comply with the applicable local and national codes. This unit comes with a dry helium charge. This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units. Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
1
(kW) 1.45 2.04
2
R410A
3
dB(A) (H/M/L) 45/40/35
622/509/399 632/526/399
1
Power Input is rated at high speed.
2
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA.
3
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
4
All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must comply with applicable and national code.
Product Data
Due to our policy of continuous product innovation, some specications may change without notication.
PRODUCT DATA | 13
GENERAL DATA AND ELECTRICAL DATA
Table 2: Unit General Data (Continued)
Type Art Cool Mirror
System (Model) LA180HSV2 (LAN180HSV2/LAU180HSV2) LA240HSV2 (LAN240HSV2/LAU240HSV2)
Piping
Liquid Line (in, OD) 3/8 Vapor Line (in, OD) 5/8 Condensation Line (OD | ID) 27/32 | 5/8 Additional Refrigerant Charge (oz/ft) 0.38 Max Pipe Length (ft) Piping Length (no add’l refrigerant, ft) Max Elevation Difference (ft) 49.2
EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit Power wiring is field supplied and must comply with the applicable local and national codes. This unit comes with a dry helium charge. This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units.
5
5
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
5
Piping lengths are equivalent.
98.4
24.6
Table 3: 208-230V, 60Hz, 1-Phase Single Zone Art Cool Mirror Outdoor Electrical Data Table
Unit Model Nos.
Nom.
Tons
Compressor Qty
Compressor(A)
Cool/Heat
Fan Qty ODU Fan(A) MCA(A) MOP(A)
Art Cool Mirror
LAU090HSV2 3/4 1 6.8/7.6 1 0.45 10 15
LAU120HSV2 1 1 6.8/7.6 1 0.45 10 15
LAU180HSV2 1 1/2 1 14.6 1 0.75 19 30
LAU240HSV2 2 1 14.6 1 0.75 19 30
For component model nos. Voltage tolerance is ±10%.
Art Cool Mirror Wall Mounted Engineering Manual
Maximum allowable voltage unbalance is 2%. MCA = Minimum Circuit Ampacity.
Maximum Overcurrent Protection (MOP) is calculated as follows: (Largest motor FLA x 2.25) + (Sum of other motor FLA) rounded down to the nearest standard fuse size.
14 | PRODUCT DATA
Due to our policy of continuous product innovation, some specications may change without notication.
10-1/2
Discharge Air Grille
21-1/2
20-29/32
OUTDOOR UNIT DIMENSIONS
LAU090HSV2, LAU120HSV2
10-29/32
30-5/16
22
1
18 -5/16
4-3/16
Product Data
8-3/32
2
2- 13/16
3
5
Unit: inch
2-3/32
6-3/32
13-29/32
4
11- 5/16
Due to our policy of continuous product innovation, some specications may change without notication.
PRODUCT DATA | 15
OUTDOOR UNIT DIMENSIONS
Discharge Air Grille
LAU180HSV2, LAU240HSV2
31-1/2
30-13/16
15-13/32
20-29/32
13-3/32
12-19/32
21-1/2
34-1/4
3-3/32
2
Art Cool Mirror Wall Mounted Engineering Manual
12-19/32
2-3/16
6-5/16
14-3/16
16 | PRODUCT DATA
Unit: inch
345
1
2
Item No. Part Name Remark
Due to our policy of continuous product innovation, some specications may change without notication.
6
INDOOR UNIT DIMENSIONS
Front Panel
Return Air Grille
LAN090HSV2, LAN120HSV2
8-1/16
1-31/32
2-13/32
1-3/4
2-5/32
1
Unit Outline
17-13/32
34-13/16
Place a level on raised tab
4
3
17-13/32
11-1/4
2
1-3/4
Product Data
2-9/16
Left rear piping
5-3/16
6-29/32
Due to our policy of continuous product innovation, some specications may change without notication.
Installation Plate
Unit: inch
2-3/4
Right rear piping
5
3-11/16
8-1/2
PRODUCT DATA | 17