•Installation MUST conform with local building codes or, in the absence
of local codes, with the Nation Electrical Code NFPA 70/ANSI C1-1003
or current edition and Canadian Electrical Code Part1 CSA C.22.1.
Power and Electrical Safety
•Immediately disconnect the product in the event of a blackout or
thunderstorm. Failure to do so may result in fire, electric shock and/
or damage.
Single Zone Art Cool Mirror Owner’s Manual
•Always insure proper equipment ground. Failure to do so may result
in electric shock and/or product failure.
•Be sure a circuit breaker is installed before using the air conditioner.
Failure to do so may result in electric shock and/or product failure.
•Do not connect the ground wire to a gas pipe, a lightning rod or a
telephone ground wire; because it may result in electric shock and/
or product failure.
•Use a standard circuit breaker and fuse conforming to the rating of
the air conditioner. Failure to do so may result in electric shock and/
or product failure.
•Do not modify or extend the power cable; because it may result in
•Failure to carefully read and follow all instructions in this manual
may result in equipment malfunction, property damage, personal injury and/or death.
electric shock and/or fire. If the power cable shows wear, such as
scratches or outer skin is peeling off or deteriorated, then it must be
replaced.
•Do not use a damaged power cord; because it may result in electric
shock and/or fire.
•Do not touch, operate or repair the air conditioner with wet hands.;
because it may result in electric shock or product failure.
•Do not place a heater or other heat generating appliances near the
power cable; because it may result in electric shock and/or fire.
•Check that the power cord is not pulled or damaged while the air
conditioner is operating. Failure to do so may result in electric shock,
and/or fire.
•Do not place any objects on the power cord; because it may result in
electric shock or product failure.
4
Due to our policy of continuous product innovation, some specications may change without notication.
Installation Safety
SAFETY INSTRUCTIONS
Single Zone Art Cool Mirror
•Do not install the air conditioner on an unstable surface or where
there is a danger of it falling; because it may result in death, serious
injury, and/or product failure.
•Contact an authorized service center when you install or relocate
the air conditioner. Failure to do so may result in serious injury and/
or product failure.
•Indoor/outdoor wiring connections must be secured tightly and the
cable should be routed properly so that there is no force pulling the
cable from the connection terminals. Improper or loose connections
may cause heat generation or fire.
•Install the panel and the cover of the control box safely. Failure to do
so may result in explosion or fire.
•Do not install the air conditioner near a place with a danger of explosion or fire; because it may result in serious bodily injury or death.
•Ensure that the pipe and the power cable which connect the indoor unit
and the outdoor unit are not pulled tight when installing the air conditioner. Failure to do so may result in electric shock or product failure.
If air enters the refrigerant system, it may result in excessively high
pressure that may lead to personal injury or damage to the equipment.
•Safely dispose of packing materials such as screws, nails or batter-
Usage
ies in a packing bag after installation or repair. Failure to do so may
result in serious bodily injury.
•Use caution when unpacking or installing the air conditioner. Failure
to do so may result in bodily injury or product failure.
•When lifting or transporting the equipment, there should be 2 or
more people, or a forklift. Failure to do so may result in bodily injury.
•Avoid exposure to leaking refrigerant which may occur during installation or repair. Failure to do so may result in personal injury and/or
product failure.
•If there is a refrigerant leak during the installation of the air conditioner, ventilate the area immediately. Failure to do so may result in
serious injury and/or product failure.
•Do not install air conditioner with direct exposure to sea water or sea
wind (salt spray); because it may result in product failure.
•Install the drain hose properly for smooth drainage of condensed
water. Failure to do so may result in product failure.
Safety
•Use only those parts which are listed in the service parts list. Never
attempt to modify the equipment; because that may result in death,
serious injury, and/or product failure.
•Discard the batteries in a safe manner and where there is no danger of
excessiveheatorre.Failuretodosomayresultinexplosionorre.
•Contact an authorized service center when the air conditioner is
submerged into water due to flooding. Failure to do so may result
in explosion or fire.
•Only use components that are approved by the manufacturer and do
not repair or modify them; because that may result in electric shock
and/or product failure.
•Only use the refrigerant specified on the air conditioner label. Failure
to do so may result in explosion or fire.
•Do not allow water to run into the air conditioner; because it may
result in explosion or fire.
•Do not leave flammable substances such as gasoline, benzene and
other white spirits or solvents, including thinner near the air conditioner because; it may result in explosion or fire and may result in
bodily injury.
•Do not use the air conditioner for an extended period of time in a
small place without ventilation; because it may result in explosion or
fire. Make sure to ventilate the space regularly.
•Do not touch the electrostatic filter after opening the front grill; because it may result in electric shock or product failure.
•For inner cleaning, contact an authorized service center or a dealer. Do
not use harsh detergent that causes corrosion or damage on the unit;
•Disconnect power if there is a noise, smell or smoke coming from the
airconditioner.Failuretodosomayresultinexplosionorre.
•Ventilate room or area when air conditioner and a heating appliance
such as a heater are used simultaneously. Failure to do so may result in fire, serious injury, and/or product failure.
•Make sure that children do not climb up the outdoor unit or impact it.
Failure to do so may result in death, bodily injury and/or product failure.
•If there is a gas leak, ventilate area sufficiently before using the air
conditioner again. Failure to do so may result in explosion or fire.
•Do not use the product for special purposes, such as preserving
foods, works of art, etc.; because it may result in death, fire and/
or electric shock. The product is a consumer air conditioner, not a
precision refrigeration system.
•Do not block the inlet or outlet of air flow; because it may result in
explosion or product failure.
•Do not insert hands or other objects through the air inlet or outlet
while the air conditioner is operating; because it may result in personal bodily injury or electric shock.
Due to our policy of continuous product innovation, some specications may change without notication.
5
SAFETY INSTRUCTIONS
Single Zone Art Cool Mirror
Usage (Continued)
•Do not expose people, animals or plants to the cold or hot wind from
the air conditioner; because it may result in serious injury.
•Do not drink the water drained from the air conditioner; because it
may result in serious health complications.
•During maintenance, be sure to turn the main power off when cleaning or repairing the air conditioner. Failure to do so may result in
death, serious bodily injury, and/or product failure.
•Do not recharge or disassemble the batteries; because it may result
in explosion, fire or serious bodily injury.
off with clean water. Failure to do so may result in serious bodily injury.
Maintenance
•Do not use strong cleaning agents or solvents when you clean the
air conditioner, or spray water; because it may result in serious
bodily injury or product failure. Make sure to use a smooth cloth
when cleaning the product.
•Do not let the air conditioner run for a long time when the humidity is
very high or when a door or window has been left open; because it
may result in product failure.
•Remove the batteries when the remote controller is not in use for an
extended period of time. Failure to do so may result in product failure.
•Filter must be installed before operating the air conditioner. Failure
to do so may result in product failure.
•Do not place any objects on the air conditioner; because it may result in product failure.
•Follow the standards of the corresponding region or country for handling the refrigerant and the air conditioner, and for disassembling
the air conditioner. Failure to do so may result in product failure.
•Do not mix the batteries for the remote controller with other types of
batteries or mix new batteries with used batteries; because it may
result in product failure.
•Never touch the metal parts of the air conditioner when removing the
airlter;becauseitmayresultinseriousbodilyinjuryorproductfailure.
•Use a sturdy stool or ladder when cleaning, maintaining or repairing
the air conditioner at a height. Failure to do so may result in serious
bodily injury or product failure.
Single Zone Art Cool Mirror Owner’s Manual
6
Due to our policy of continuous product innovation, some specications may change without notication.
UNIT PARTS
Single Zone Art Cool Mirror
The following table shows the available outdoor and indoor units, their model numbers, along with the factory provided controller.
Table 1: Single Zone Art Cool Mirror Pairing Table
Outdoor Unit Model/ Btu/hIndoor Unit Model/ Btu/hController
LAU090HSV2 / 9,000
LAU120HSV2 / 12,000
LAN090HSV2 / 9,000
LAN120HSV2 / 12,000
AKB73635606
LAU180HSV2 / 18,000
LAU240HSV2/ 24,000
LAN180HSV2 / 18,000
LAN240HSV2 / 24,000
AKB73635606
Unit Parts
Due to our policy of continuous product innovation, some specications may change without notication.
7
UNIT PARTS
Basic Components
Indoor Unit Basic Components
Refer to Figure 1 for the basic layout of the components of the Art Cool Mirror indoor unit,
when following operational, maintenance or troubleshooting instructions in this manual.
Air inlet
On/ Off button
Front panel
(Front cover)
Air filter
Air outlet
Air deflector
(Vertical louver & Horizontal vane)
Signal receiver
Operation lamp
Figure 1: Art Cool Mirror Indoor Unit Basic Components
Outdoor Unit Basic Components
Refer to Figure 2 for the basic layout of the components of the Art Cool Mirror outdoor unit,
when following operational, maintenance or troubleshooting instructions in this manual.
Air inlet vents
Single Zone Art Cool Mirror Owner’s Manual
Air outlet vents
Base plate
Refrigerant pipes
Drain hose
Connection
wire
Figure 2: Art Cool Mirror Outdoor Unit Basic Components
8
Due to our policy of continuous product innovation, some specications may change without notication.
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.