LG IrisAccess™ 4000: iCAM4100 Quick Start Guide
The content of this document is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by LG Electronics USA Incorporated. LG Electronics USA Incorporated assumes no responsibility or liability for any errors or inaccuracies that may appear in the informational content contained in this document.
Please remember that existing images or drawings that you may want to include in your document may be protected under copyright law. The unauthorized incorporation of such material into your work could be a violation of the rights of the copyright owner. Please be sure to obtain any permission required from the copyright owner.
LG, LG Iris, the LG logo, LG Iris logo and IrisAccess are either registered trademarks or trademarks of LG Electronics Incorporated in the United States and/or other countries.
LG Electronics USA Incorporated, Iris Technology Division. 7 Clarke Drive, Cranbury, New Jersey 08512, USA.
1
Packing List
What’s in the box
• iCAM4100 - IrisCamera
• Power Adapter Input: 110~240V AC - 1.5AMP 50/60Hz Output: 12V DC - 5.0AMP
• Power Cable for 110V
• CAT5 Ethernet Cable
• Quick Start Guide
• Security Screw Wrench
Required Equipment (not included with iCAM4100)
• Server Computer (refer to the Hardware Manual for details)
• Ethernet Switch
• Ethernet Wiring
• Uninterruptible Power Supply
2
iCAM4100 in the IrisAccess System
Ethernet
Door Control
RS-422 Serial
Network Switch
ICU DCU
The iCAM4100 is a two-eye iris camera used to capture the iris images of the user. The iCAM includes an alignment indicator behind the mirror and voice prompts to assist the user. A Vacuum Fluorescent Display (VFD) displays system time, date, and user guidance. When used in a typical access control application, the iCAM is placed near the secured portal to provide user identification. The optional keypad can be used for a PIN verification mode.
The iCAM can be used in enrollment mode using the IrisEnroll application (included with EAC software) or recognition mode when it is configured for use with an ICU. The iCAM can not easily be switched between enrollment and recognition modes once configured.
The iCAM can be wall mounted or used with an optional desk-top stand.
iCAM4100 Model Variations
Smartcard Reader
VFD
iCAM4100 iCAM4100R iCAM4101 iCAM4101R iCAM4110-H1 iCAM4110R-H1 iCAM4110-E1 iCAM4110R-E1 iCAM4111-H1 iCAM4111R-H1 iCAM4111-E1 iCAM4111R-E1
RoHS compliant Keypad HID iClass IE Smart-ID
3
Installation Requirements
bottom of mirror
61”
(155mm)
floor
• The recommended mounting height for the iCAM4100 is 140cm (55 inches) from the floor to the bottom of the unit. This mounting height can be adjusted to accommodate the average user height at the installed location.
• High amounts of ambient light must be avoided. Intense light sources such as sunlight or halogen lamps may reduce the image capture performance of the iCAM, this may result in an increased “failure to acquire” rate.
• The iCAM is not weatherproof and must not be exposed to precipitation or extreme temperatures. An enclosure may be used to protect the unit if required. See www.lgiris.com – Support & Service for more information.
• All system components including the Ethernet network must be powered through Uninterruptible Power Supplies (UPS). UPS must provide power line filtering as well as power back-up operation.
• Each IrisAccess™ system component on the Ethernet network system must have a unique manually assigned IP address.
55” (140mm)
The iCAM4100 requires at least the following wires:
• Ethernet network wiring to connect with the network switch to communicate to the IrisServer or an ICU. * Note: For systems consisting of only an IrisServer and iCAM may use an Ethernet crossover cable to connect the iCAM directly to the IrisServer computer.
• Power (12VDC +/-10% and 2.5Amps MAX)
IMPORTANT: IT IS RECOMMENDED TO USE THE POWER ADAPTER SUPPLIED WITH THIS PRODUCT. AN OVER OR UNDER VOLTAGE APPLIED TO THIS PRODUCT MAY CAUSE PERMANENT DAMAGE AND VOID THE WARRANTY.