LG H20F50DT Owner's Manual

© Copyright 2003, Zenith Electronics Corporation
Installation and Operating Guide | Warranty
Model Number | H20F50DT | HealthView
TM
TV
table of contents
page
5
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.
POWER CORD POLARIZATION:
This product is equipped with a 3-wire grounding-type alternating current line plug. This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the three-wire ground type plug.
NOTE TO CABLE/TV INSTALLER:
This reminder is provided to call the cable TV system installer’s attention to Article 820-40 of the National Electric Code (U.S.A.). The code provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of the cable entry as practical.
REGULATORY INFORMATION:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CAUTION:
Do not attempt to modify this product in any way without written authorization from Zenith Electronics Corporation. Unauthorized modification could void the user’s authority to operate this product.
COMPLIANCE:
The responsible party for this product’s compliance is: Zenith Electronics Corporation, 2000 Millbrook Drive, Lincolnshire, IL 60069, USA. Phone: 1-847-941-8000.
WARNING
RISK OF ELECTRIC SHOCK DO NOT OPEN
3-WIRE COMM-WARN B-2/02
HealthViewTMis a trademark of Zenith Electronics Corporation
© Copyright 2003 Zenith Electronics Corporation
RECORD THE MODEL NUMBER
The serial number of this HealthViewTMTV is located on the back of the cabinet. For future reference, we suggest that you record the serial number here:
MODEL NO. H20F50DT
SERIAL NO.____________________________________
For Customer Support/Service please call:
1-888-865-3026
www.zenith.com
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
Important safety instructions shall be provided with each apparatus. This information shall be given in a separate booklet or sheet, or be located before any operating instructions in an instruction for installation for use and supplied with the apparatus.
This information shall be given in a language acceptable to the country where the apparatus is intended to be used. The important safety instructions shall be entitled “Important Safety Instructions”. The following safety instructions shall be included where applicable, and, when used, shall be verbatim as follows. Additional safety information may be included by adding statements after the end of the following safety instruction list. At the manufacturer’s option, a picture or drawing that illustrates the intent of a specific safety instruction may be placed immediately adjacent to that safety instruction:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from type-over.
PORTABLE CART WARNING
(Continued on next page)
P A G E 3
IMPORTANT SAFETY INSTRUCTIONS
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all the servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has exposed to rain or moisture, does not operate normally, or has been dropped.
15. CAUTION concerning the Power Cord:
Most appliances recommend they be placed upon a dedicated circuit; that is, a single outlet circuit which powers only that appliance and has no additional outlets or branch circuits. Check the specification page of this owner’s manual to be certain.
Do not overload wall outlets. Overloaded wall outlets, loose or damage wall outlets, extension cords, frayed power cords, or damaged or cracked wire insulation are dangerous. Any of these conditions could result in electric shock or fire. Periodically examine the cord of your appliance, and if its appearance indicates damage or deterioration, unplug it, discontinue use of the appliance, and have the cord replaced with an exact replacement part by an authorized servicer.
Protect the power cord from physical or mechanical abuse, such as being twisted, kinked, pinched, closed in a door, or walked upon. Pay particular attention to plugs, wall outlets, and the point where the cords exits the appliance.
16. Outdoor Use Marking: WARNING - To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture.
17. Wet Location Marking: Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus.
P A G E 4
PAGE 5
Table of Contents
Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Important Safety Instructions . . . . . . . . . . . . . . . . 3 - 4
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Step 1. Hook Up the HealthView TV
TV and other Equipment Hookups
Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Cable Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Antenna with VCR . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Cable service with VCR . . . . . . . . . . . . . . . . . . . . . . . 9
External Speaker Connection (8-ohm output) . . . . . . . . 9
Pillow Speaker . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Step 2. Channel Search and Reception Setup
Auto Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
(Select Antenna, or cable service then do channel search)
Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . 12
Optional Installer’s Remote Key Functions . . . . . . . . . . 13
On-Screen Menus Overview . . . . . . . . . . . . . . . . . . . 14
Step 3. Customize the TV’s Features
Setup Menu (Start with page 11, Auto Program)
Add/Del/Blank . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Channel Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Clock Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
On/Off Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Captions (Caption/Text) . . . . . . . . . . . . . . . . . . . . . 19
Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Video Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
FM Radio Menus . . . . . . . . . . . . . . . . . . . . . . 22 - 23
Installer Parental Control Menu . . . . . . . . . . . . 24 - 25
Other Menus and On-Screen Displays . . . . . . . . . . . . 26
Managing the Channel Banks . . . . . . . . . . . . 27 - 28 - 29
Installer Menus . . . . . . . 30 - 31 - 32 - 33 - 34 - 35 - 36
LT2000 Quickset II Clone Programmer . . . . . . 37 - 38 - 39
Patient Operation Section (Copy for patient usage)
Optional Patient Remote Key Functions . . . . . . . . . . . 40
Optional Patient Remote Key Functions - FM Radio . . . . 41
Patient Parental Control Menu . . . . . . . . . . . . . . 42 - 43
Patient Menus and On-Screen Displays . . . . . . . . . . . . 44
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Warranty for HealthView Series TVs . . . . . . . . . Back Cover
Purchase the Optional Installer’s Remote and Clone Programmer
To perform a normal installation set up, you need an installer’s remote such as the HP602, and the LT2000 Quickset II Clone Programmer—both are shown and described in later sections. The installer remote allows access to the Installer menus, User menus, and Source/Channel Bank keys. The installer remote has Menu, Select, and Adjust, and Channel Bank Keys. The LT2000 Quickset II Clone Programmer is used to duplicate a TV’s setup and install it on another identical TV. See your Zenith Dealer.
Design and specifications subject to change without prior notice.
Installer/Hospital Note:
Pages 40, 41, 42, 43, and 44 contain information and menus which the patient can use to operate the TV. It is recommended that these four pages be copied and included with the literature packet that the hospital provides to the patient.
206-3853
Optional Installer and Patient Remote Controls:
Shown herein are optional remote controls that can be used by the installer and the patient. Be advise that these remote controls are NOT included with this TV. However, these remotes can be pur­chased separately, see your Zenith dealer.
Use the steps outlined below as a setup guide and to determine the TV features that will require adjustment for the needs of the end user
PAGE 6
206-3491-O
Mini glossary
75 OHM RF CABLE The wire that comes from an off-air antenna or cable service provider. Each end looks like a hex shaped nut with a wire
sticking through the middle, and it screws onto the threaded jack on the back of the TV.
A small device that connects a two-wire 300 ohm antenna to a 75 ohm RF jack. They are usually about an inch long with two screws on one end and a round opening with a wire sticking out on the other end.
Antenna Hook Up
Connect an off-air antenna to the HealthView TV
If you have a 75 ohm RF cable, then you don’t need any adapters.
A 300 to 75 ohm adapter is not included with the Zenith HealthView TV.
300 TO 75 OHM ADAPTER
ANTENNA
CABLE
M.P.I.
TV Back
Flat wire
(300 ohm)
Antenna
300/75 ohm
Adapter
TV Back Panel
(Expanded View)
PILLOW SPEAKER
TV
SPKR
PILLOW
SPKR
VideoInSpeaker
Out
Audio
In
ANTENNA
CABLE
M.P.I.
TV Back
Antenna
TV Back Panel
(Expanded View)
RF Coaxial Wire
(75ohm)
PILLOW SPEAKER
TV
SPKR
PILLOW
SPKR
VideoInSpeaker
Out
Audio
In
Locate the Antenna/Cable jack on the back of the HealthView TV.
Connect the antenna wire that runs from the wall to this jack, according to one of the dia­grams shown to the right.
Remove the back of the optional remote and put in two AA batteries.
Plug in the TV. The HealthView TV is designed to operate on standard current, 120-volt 60 Hertz AC. Do not attempt to operate it on DC power.
Go to page 11 to Auto Program the TV.
Back of Remote
1
2
3
4
5
PAGE 7
206-3491-O
Cable Service (CATV) Hook Up
If you’re using a cable box, leave the TV on channel 3 or 4 and use the cable box to change channels.
If you’re using a cable box, Auto Program might only find the channel the cable service is on (usual­ly channel 3 or 4).
Cable TV Wall Jack
RF Coaxial Wire
(75ohm)
ANTENNA
CABLE
M.P.I.
TV Back
TV Back Panel
(Expanded View)
PILLOW SPEAKER
TV
SPKR
PILLOW
SPKR
VideoInSpeaker
Out
Audio
In
Cable TV Wall Jack
Cable Box
In
Out
RF Coaxial Wire
(75ohm)
3 4
output
switch
ANTENNA
CABLE
M.P.I.
TV Back
TV Back Panel
(Expanded View)
PILLOW SPEAKER
TV
SPKR
PILLOW
SPKR
VideoInSpeaker
Out
Audio
In
Locate the Antenna/Cable jack on the back of the HealthView TV.
Connect the cable service wire that runs from the wall, according to one of the dia­grams to the right.
Remove the back of the optional remote and put in two AA batteries.
Plug in the TV. The HealthView TV is designed to operate on standard current, 120-volt 60 Hertz AC. Do not attempt to operate it on DC power.
Go to page 11 to Auto Program the TV.
Back of Remote
1
2
3
4
5
Connect cable service to the HealthView TV
PAGE 8
206-3491-O
Antenna with VCR Hook Up
Connect an off-air antenna and VCR to the HealthView TV
Locate the Antenna/Cable in jack on the back of the VCR.
Connect the antenna wire according to one of the diagrams to the right.
Remove the back of the optional remote and put in two AA batteries.
Plug in the TV. The HealthView TV is designed to operate on standard current, 120-volt 60 Hertz AC. Do not attempt to operate it on DC power.
Go to page 11 to Auto Program the TV.
Back of Remote
1
2
3
4
5
In
Out
Audio
Video
3 4
VCR Back
VCR Back AV Panel
output
switch
Round
Or
Flat wire
(300 ohm)
300/75 ohm
Adapter
TV Back
ANTENNA
CABLE
M.P.I.
TV Back Panel
(Expanded View)
PILLOW SPEAKER
TV
SPKR
PILLOW
SPKR
VideoInSpeaker
Out
Audio
In
Antenna
206-3684-A
Cable Service (CATV) with VCR Hook Up
Connect Cable service and a VCR to the HealthView TV
Leave the VCR and the television tuned to channel three or four and use the cable box to change channels.
Locate the Antenna/Cable in jack on the back of the VCR.
Connect the wire that runs from the cable service wall jack, according to one of the diagrams to the right.
Remove the back of the optional remote and put in two AA batteries.
Plug in the TV. The HealthView TV is designed to operate on standard cur­rent, 120-volt 60 Hertz AC. Do not attempt to operate it on DC power.
Go to page 11 to Auto Program the TV.
Back of Remote
1
2
3
4
5
PAGE 9
In
Out
Audio
Video
3 4
VCR Back
VCR Back AV Panel
output
switch
TV Back
ANTENNA
CABLE
M.P.I.
TV Back Panel
(Expanded View)
PILLOW SPEAKER
TV
SPKR
PILLOW
SPKR
VideoInSpeaker
Out
Audio
In
Cable TV Wall Jack
Cable Box
In
Out
3 4
output
switch
Cable TV Wall Jack
External Speaker Connection (8-ohm)
TV Back
ANTENNA
CABLE
M.P.I.
TV Back Panel
(Expanded View)
PILLOW SPEAKER
TV
SPKR
PILLOW
SPKR
VideoInSpeaker
Out
Audio
In
A/V cables
not included
with TV
8-ohm Speaker In
Speaker Back
Connect Speaker out to an 8-ohm speaker as shown.
PAGE 10
206-3491-O
Pillow Speaker Hook Up
Locate the Pillow Speaker Output jack on the back of the HealthView TV.
Connect an accessory pillow speaker or wired remote control unit to this 6-pin jack.
Select PILLOW SPKR on the rear panel of the HealthView TV.
Use a pillow speaker by Curbell, Model A-16455-02 or other UL recognized pendant control bearing the warning:
“Risk of fire if used in oxygen enriched atmosphere. Keep pendant control away from oxygen equipment.”
TV
TV Back
ANTENNA
CABLE
M.P.I.
TV Back Panel
(Expanded View)
PILLOW SPEAKER
TV
SPKR
PILLOW
SPKR
VideoInSpeaker
Out
Audio
In
1
2
Connect a pillow speaker to the HealthView TV
3
TV ON/OFF
CHAN DOWN
CHAN UP
(MALE PLUG)
VOLUME CONTROL
SPKR.
5
1
4
6
2
1
2
3
4
5
6
3
1
5
2
4
6
TV ON/OFF
OPEN
CHAN UP/DATA IN
COMMON
AUDIO OUT
CHAN DOWN
Controlling the TV with mechanical switches
Pin 4 (common) is momentarily connected to pin 1, 3, or 6 via push-action switches to control On/Off and Channel Up/Down. These pins are at +13 volts DC (when measured from pin 4) with the switches open. Current draw is 8 mA when a switch is closed. (This operation is identical to previous Zenith models using the 5-Wire Interface except that only +7 volts DC was supplied and current draw was only 2.5 mA.)
Pillow Speaker Interface
This connector furnishes three control lines and an audio output. A patient-pendant remote control, or entertainment audio and nurse call system may be connected here. All lines are isolated from the AC power line and earth ground. (Opto-isolators isolate the control lines, and a transformer isolates the audio. There are no relays or inductive components in the control lines.)
Pin no. Purpose
1 External TV On/Off switch 2 (not used) 3 External Channel Up switch or Data in 4 Common connection for control, data,
and audio output. Impedance to earth ground is a 10-meg resistor in parallel with a 1100 pf capacitor.
5 Isolated audio output. Nominal 14-ohm source
impedance with short circuit protection. Intended for a pillow speaker with a low-impedance pad-type volume control.
6 External Channel Down switch
Pillow speaker not included with HealthView TV.
3
Controlling the TV with Serial Data
The TV is capable of being controlled by a single-wire, serial data signal. This is a Zenith patented technology and is being implemented by certain brands of “smart” pillow speakers, such as Curbell’s “GEN-II” models.
PAGE 11
206-3747
Auto Program (Channel Search)
Use Auto Program to specify Cable TV or Off Air Antenna incoming signal source and automatically store in the mem­ory of the TV, all of the channels that are found by the channel search
With the optional Installer remote control in hand, press the POWER key to turn on the HealthView TV.
Press the MENU key to show the Setup menu.
Using SELECT on the remote control, highlight Auto Program on the screen.
Press the Right or Left ADJ (Adjust) arrow to go to the Auto Program menu.
Using SELECT, choose either Cable TV or Off Air Antenna on the screen.
Press the Right or Left ADJ arrow to begin the Channel Search.
Press ENTER when the channel search is complete.
1
2
3
4
5
6
7
123
456
7
0
8
ENTER
9
POWER
TV/FM
FLSHBK
MUTE
VOLUME
CHANNEL
MENU
ADJ ADJ
SELECT
TIMER
BANK
CH PREVIEW
BED 1
BED 2
CC
-
+
-
+
3/5
AUTO PROGRAM ADD/DEL/BLNK CH. LABELS CLOCK SET TIMER CAPTIONS LANGUAGE
Mini glossary
OFF AIR ANTENNA If the patient can only view over-the-air broadcasts, select Antenna.
CABLE If you provide cable service to the patients, select Cable.
Auto Program finds channels being received by the TV tuner.
Cable will not work unless the hospital provides a cable service.
4/6
1
7 2
Optional Installer and Patient Remote Controls:
Shown herein are optional remote controls that can be used by the installer and the patient. Be advise that these remote controls are NOT included with this TV. However, these remotes can be purchased separately, see your Zenith dealer.
PAGE 12
206-3491-O
Front Panel Controls
power
channel
volume
captions
4
Press the POWER button to turn on the HealthView TV.
Use the CHANNEL button to cycle through avail­able channels.
Use the VOLUME button to adjust the sound level of the HealthView TV.
Press CAPTIONS repeatedly to turn selected closed captions option On or Off. (See Captions page.)
Using the front control panel to operate the television
1
2
3
2
3
1
4
PAGE 13
206-3853
Installer Remote Key Functions
123
456
7
0
8
ENTER
9
POWER
TV/FM
FLSHBK
MUTE
VOLUME
CHANNEL
MENU
ADJ ADJ
SELECT
TIMER
BANK
CH PREVIEW
BED 1
BED 2
CC
-
+
-
+
FLASHBK (FLASHBACK)
Return to the last channel viewed.
POWER
Turns TV On or Off
.
CHANNEL (UP/DOWN)
Tunes to next available channel.
MUTE
Turns sound Off and On, while the picture remains.
ENTER
Press to view the Channel/Time display or to remove any on-screen display or menu.
NUMBER KEYPAD
Selects channels directly and enters numeric values for some options
.
remote control part number
HP602
124-213-06
TIMER
Press repeatedly to adjust TV turn-off time
up to 4-hours.
Use to pick AM/PM in Clock menu.
VOLUME LEFT/RIGHT
Adjusts the sound levels.
CC (CLOSED CAPTIONING)
Press to access closed captions.
Press ENTER to exit.
A quick list of the keys on the optional HP602 installer’s remote and what they do
BANK
Press and repeat to select a Channel Memory Bank - - 1, 2, 3, or 4 (standby).
MENU/SELECT/ADJ (ADJUST)
Press MENU repeatedly to scroll through
either the Installer, or User menus. Use
SELECT to choose an option and ADJ
(adjust) to change the selected option.
CHANNEL PREVIEW
Gives installer access to the patient’s menus. Displays the available TV channels and patient’s Parental Control menu.
TV/FM
Selects TV or Radio on TVs equipped with
FM radio.
BED 1/BED 2 (*See Note Below)
Determines the code set transmitted, Bed 1 or Bed 2. Switch setting must corre­spond to item 27, HOSPITAL MODE setting in the TV’s Installer Menu.
*Note: Bed 1 - Bed 2 switch on installer/patient remote. The position of the Bed 1 ­Bed 2 switch must correspond to the setting in the Installer’s menu. The switch above can be set by sliding it to the Bed 1 or Bed 2 position. On the patients’ remote, the Bed 1 or Bed 2 position can be selected by using a paper clip or a ball-point pen to slide the switch to the correct position. Left position = Bed 1. Right Position = Bed 2.
PAGE 14
206-3491-O
On-Screen Menus Overview
ON-SCREEN MENUS
Setup Menu Adjusts the basic characteristics of the TV
Auto Program 11 Automatically finds and stores active channels to scroll through using Channel Up/Down.
Add/Del/Blnk 15 Manually choose which active channels will appear when using Channel Up/Down.
Channel Labels 16 Labels the channels with their network names (ABC, CBS, HBO, etc.) or create custom names.
Clock Set 17 Sets the time.
On/Off Timers 18 Set the timers to automatically turn the TV On/Off each day at the preset time(s).
Captions 19 Chooses the captioning or text option.
Language 20 Chooses the language the on-screen menus will appear in.
Video Menu 21 Adjusts the picture appearance. The options are: Contrast, Brightness, Color, Tint, Sharpness,
Picture Pref.
FM Radio Menu 22 Adjusts the FM Radio options.
Parental Control 24 Allows installer to restrict viewable programming for up to 99 hours, with the use
of a password.
26 OTHER MENUS AND ON-SCREEN DISPLAYS
Channel/Time Shows the current time, selected channel and XDS* data if available.
Sleep Timer Sets the time the TV will turn off.
Volume Shows current sound level.
Captions Sets Caption/Text options.
Ch Preview Displays the available channels list.
Channel Bank Shows currently selected channel bank.
Inactive TV Prompts the patient to arrange for TV service.
INSTALLER MENUS 30 Sets up the TV’s operating features.
*XDS (Extended Data Service) Additional program information provided at the discretion of the broadcaster. May include: title of broadcast, length of broadcast, and time remaining until end of broadcast.
Descriptions of the menus on the TV
Using the Menu button on the optional installer’s remote, the installer can access all the menus below.
Menu Name Page Description
PAGE 15
NOAUX3684
Fine-tune the patient’s channel selection list
Setting Add/Delete/Blank
Press the MENU key on the optional Installer’s remote to show the Setup menu on the screen.
Press SELECT repeatedly to highlight the Add/Del/Blnk option.
Using either the NUMBER keypad and ENTER or the Channel Up/Down arrows on the remote, select a channel. (If adding a deleted channel, you will need to use the number keypad and ENTER.)
Using the Right/Left ADJ arrow, choose whether the chan­nel is Added, Deleted, or Blank.
To continue, select another channel and repeat Step 3. When you are finished, press ENTER to remove menu.
Adding VCR 3, VCR 4, or FM to the Channel Preview List
Go to the Setup menu, select the Add/Del/Blnk option. Use Channel Up/Down to select the option and choose Added. Note: If the option was turned off in the Service menu, you will have to reinstate it before it can appear as an option in the Channel Preview list.
Note: You can elect to Add, Delete or Blank: VCR 3 and VCR 4. FM can be Added or Deleted, but not Blanked.
1
2
3
4
5
123
456
708
ENTER
9
POWER
TV/FM
FLSHBK
MUTE
VOLUME
CHANNEL
MENU
ADJ ADJ
SELECT
TIMER
BANK
CH PREVIEW
BED 1
BED 2
CC
-
+
-
+
2
AUTO PROGRAM ADD/DEL/BLNK CH. LABELS CLOCK SET TIMER CAPTIONS LANGUAGE
CH 44 ADDED
SETUP MENU
Mini glossary
ADD Adds new channels to the list that the patient can scroll through when using the remote.
DELETE Removes channels for one reason or another from the list that the patient can scroll through.
BLANK Removes the video signal from a channel so the patient will only receive the audio signal.
4
3/5
1
If you delete a channel, it isn’t gone for good. Just select it using the NUMBER keypad on the remote, or add it later.
3
3
Loading...
+ 33 hidden pages