LG GR-C460RLCN, GL-C432RQCN, GL-C400RLCN, GL-C432RLCN, GL-C400RQCN, GR-C460RQCN, GR-C420RLCN Owner’s Manual
ENGLISH
RUSSIAN
UZBEK
P/NO : MFL68489013
Green Ion Door Cooling /
Ice Beam Door Cooling(Optional)
3
10
11
13
Lamp Replacement
Inverter On feature(Optional)
2
20
21
22
22
24
WARNING
Keep ventilation openings, in the appliance enclosure or in
the built-in-structure, clear of obstruction.
Do not use mechanical devices or other means to accelerate
the defrosting process, other than those recommended by the
manufacturer.
Do not damage the refrigerant circuit.
Do not use electrical appliances inside the food storage
compartment, unless they are recommended by the
manufacturer.
The refrigerant and insulation blowing gas used in the
appliance requires special disposal procedures. When
disposal, please consult with services agent or a similarly
qualified person.
3
If gas used is R600a
This appliance contains a small amount of isobutane refrigerant
(R600a), natural gas with high environmental compatibility, but it is
also combustible. When transporting and installing the appliance,
care should be taken to ensure that no parts of the refrigerating
circuit are damaged. Refrigerant squirting out of the pipes could
ignite or cause an eye injury. If a leak is detected, avoid any naked
flames or potential sources of ignition and air the room in which the
appliance is standing for several minutes.
Never startup an appliance showing any signs of damage. If in
doubt, consult your dealer.
4
5
Do not use or store
inflammable materials like
ether, benzene, alcohol,
medicine, LP gas, spray or
cosmetics
near or in the
refrigerator.
It may cause
explosion or fire.
6
7
Do not store glass bottles
that can break easily in the
compartment which is
0
below 0 C
8
Do not hang climb or stand on the drawer
compartment or shelf of the refrigerator
Do not insert the shelf from wrong side
Please be careful while assembly & disassembly of glass shelf
9
6. Install Ref from long distance from power
plug.
Inverter-On feature (Optional)
Minimum requirement: UPS/ Inverter
should be in ON condition having
minimum 600VA capacity along with
minimum 120Ah capacity battery
connected with the refrigerator’s power
supply socket.
10
Door Cooling +
1
LED Lamp
Refrigerator Door
Basket
11
12
‘3’ or ‘4’.
When the Freezer compartment is not enough cold in winter, adjust the control for the freezer to High
(4/5/ ● / )
●●
For achieving temperature in Freezing , Energy and Storage Test, Freezer control may be required to set at
“●” or “●●”
Freezer Control
451
NormalMinMax
Recommended Location
4
5
For Regular Models
13
41
Superchill
ColdColdest
Ref.
Temp.
14
Superchill
ColdColdest
Temperature Control
Ref.
Temp.
High
Low
15
DOOR COOLING (OPTIONAL)
16
17
SMART DIAGNOSIS (Only for Selected External Micom Models)
Use this function when calling the Customer Call Centre and receive precise diagnosis when the
Refrigerator malfunctions or fails. Use it only when advised by the consultant and not otherwise.
18
SMART DIAGNOSIS (Only for Selected Internal Micom Models)
Smart diagnosis function is...
Use this function when calling the Customer Call Centre and receive precise diagnosis when the
Refrigerator malfunctions or fails. Use it only when advised by the consultant and not otherwise.
How to use the function
First, call LG service center. Only use the Smart Diagnosis feature when instructed to do so by the LG
call center agent.
1.Open all the doors of the refrigerator.
2.Press the refrigerator control (REF
TEMP) button for 3 sec or more.
Superchill
5.Do not take away the telephone while
data is being transmitted.
CAUTION
The transmission sound may be irritating.
Do not take away the telephone until the sound
stops for good diagnosis.
ColdColdest
3.If the buzzer sounds 4 times (Frequency
of SDS Buzzer is 2000Hz, 0.2sec Off/
0.2sec On 4 times) place the phone near
the speaker hole in the top right hand
side door hinge.
4.Ensu r e th e mi c r o phone of t h e
telephone is towards the speaker hole.
Ref.
Temp.
6.During the data transmission for smart
diagnosis, hold the telephone 10cm
away from the speaker hole and avoid
any background noises. After inputting
SDS, SDS buzzer will ring. After
completion of the data transmission,
the consultant will explain the result of
the smart diagnosis and advice
a c c o r d in gl y. W h e n t h e d a t a
tra n smiss i on i s c o mplet e d, t he
refrigerator will be automatically turned
off and on a few seconds later.
Be aware!
Difference of the regional call qualities may have influence on the function.
If you use home phone, better communication performance will enable much better service.
Smart diagnosis data transmission may not be successful if the call is made from a mobile phone
with poor network reception.
19
LAMP REPLACEMENT
NOTE : This product applies LED Lamp which cannot be replaced
by the user. Please contact authorized service centre for
the lamp replacement.
INVERTER-ON FEATURE (Optional)
1. While using this feature, the refrigerator will work on basic requirement as required by
the product.
2. The results of the Inverter-On feature may vary depending on the number of appliances
that are running on inverter.
3. For optimum running of refrigerator during Inverter-On mode, it is recommended to
switch off the other appliances which are not in use.
4. It is recommended to confirm the quality of food items before consumption.
5. Ice cream etc. may get soften during the use of this feature, if situation arises so, it is
recommended to change the setting as per one’s choice.
20
21
SUPPLY CORD
REPLACEMENT
If the supply cord is damaged, it
must b e r eplaced by th e
manufacturer or its service agent
or a similarly qualified person in
order to avoid a hazard.
22