The refrigerant and insulation blowing gas used in the appliance requires special disposal
procedures. When disposal, please consult with services agent or a similarly qualified person.
This guide contains many important safety messages. Always read and obey all safety messages.
This is the safety alert symbol. It alerts you to safety messages that inform you of hazards that can
hurt or seriously injured or cause damage to the product. All safety messages will be preceded by
the safety alert symbol and the hazard signal word DANGER, WARNING, or CAUTION. These
words mean:
DANGER
WARNING
CAUTION
You will be hurt or seriously injured if you don’t follow instructions.
To reduce the risk of fire, electric shock, or injury to persons when using your
product, basic safety precautions should be followed, including the following.
Read all instructions before using this appliance.
Indicates an imminently hazardous situation which, if not avoided, may result
in minor or moderate injury, or product damage only.
3
IMPORTANT SAFETY INFORMATION
Disposal of your old appliance (as per e-waste Rules)
1. When this crossed out wheeled bin symbol is depicted on the product and its operator's
manual, it means the product is covered by the e-waste Management and Handling
Rules, 2011 and are meant to be recycled, dismantled, refurbished or disposed off.
2. Do's
a. The product is required be handed over only to the authorized recycler for
b. Keep the product in isolated area, after it becomes non-functional/un-repairable so as to
prevent its accidental breakage.
Don'ts
a. The product should not be opened by the suer himself/herself, but only by authorized service
personnel.
b. The product is not meant for re-sale to any unauthorized agencies/scrap dealer/kabariwalah.
c. The product is not meant for mixing into household waste stream.
d. Do not keep any replaced spare part(s) from the product in exposed area.
3. Any disposal through unauthorized agencies/person will attract action under Environment
(Protection) Act 1986.
4. Hazards of improper handling or accidental breakage :
a. The refrigerant (R134a) used, if overexposed, might cause dizziness and loss of concentration.
Liquid contact can cause irritation and frostbite. The refrigerant (R600a), squirting out of the
pipes could ignite or cause eye injury.
b. The blowing agent cyclopentane is highly flammable liquid and vapor, harmful to aquatic life.
Contact with liquid may cause cold burns/frost bites. Repeated exposure cause skin dryness.
5. To locate a nearest collection centre or call for pick-up (limited area only) for disposal of this
appliance, please contact Toll Free No. for details. All collection
centre and pick up facilities are done by third parties with LG electronics India Pvt. Ltd. merely as a
facilitator.
For more detailed information, please visit : http://www.lg.com/in
disposal.
1800-315-9999, 1800-180-9999
1800-315-9999, 1800-180-9999
4
IMPORTANT SAFETY INFORMATION
WARNING/
To reduce the risk of fire, electric shock, or injury to persons while using your product, the following
basic safety precautions should be followed. Read all instructions before using this appliance.
This appliance contains a small amount of isobutane refrigerant (R600a), natural gas with high environmental
compatibility, but it is also combustible. When transporting and installing the appliance, care should be taken to
ensure that no parts of the refrigerating circuit are damaged. Refrigerant squirting out of the pipes could ignite or
cause an eye injury. If a leak is detected, avoid any naked flames or potential sources of ignition and ventilate the
room in which the appliance is installed for several minutes.
In order to avoid the creation of a flammable gas air mixture if a leak in the refrigerating circuit occurs, the size of the
room in which the appliance may be installed depends on the amount of refrigerant used. The room must be 1m in
size for every 8g of R600a refrigerant inside the appliance. The amount of refrigerant in your particular appliance is
shown on the label on the back of the appliance.
Never start up an appliance showing any signs of damage. If any doubt, consult your dealer.
The refrigerant and insulation blowing gas used in the appliance requires special disposal
procedures. When disposal, please consult with services agent or a similarly qualified person.
Natural Gas (isobutene, R600a) environment-friendly
refrigerant, even a small
amount (30~90g) is
combustible. When the
gas is leaked due to
severe damage during
delivering, installing or
using the refrigerator, any spark may cause fire
or burn.
Do not insert hand or metal stick into the
cool air vents, cover, bottom of the
refrigerator & heat proof grill (exhaust hole)
at backside.
It may cause electric
shock or injury.
What to do with your old refrigerator,
AmnHo$ nwamZo àerVH$ `§Ì H$m {ZKQ>mZ
Your refrigerator contains liquid
(refrigerant, lubricant) made of
recyclable materials, All these
materials must be sent to a
recycling waste disposal site as
they can be reused after a
specific recycling process.