LG LRG30355, GAS RANGE Installation Instructions Manual

GAS RANGE
INSTALLATION INSTRUCTIONS
Please read this guide thoroughly
before installation.
BEFORE YOU BEGIN
To contact LG Electronics, 24 hours a day, 7 days a week:
1-800-243-0000
Or visit us on the Web at: us.lge.com
Read these instructions completely and carefully.
Installation of this range must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA.54, latest edition. In Canada, installation must conform with the current Natural Gas Installation Code, CAN/CGA­B149.1 or the current Propane Installation Code, CAN/CGA-B149.2, and with local codes where applicable. This range has been design-certified by CSA International according to ANSI Z21.1, latest edition and Canadian Gas Association according to CAN/CGA-1.1 latest edition.
As with any appliance using gas and generating
e certain safety pr
heat, ther should follow the Important Safety Information section in your User’
IMPORTANT – Save these instructions for
local electrical inspector’s use.
IMPORTANT – Observe all governing
• codes and or
e ar
ou will find these pr
. Y
s Guide. Read them car
dinances.
ecautions you
ecautions in
efully.
Note to Installer: Leave these instructions with the appliance after installation is completed.
Note to Consumer: Keep the User’s Guide and Installation Instructions for future reference.
NOTE: This appliance must be properly grounded.
• The electrical diagram is in an envelope attached to the back of the range.
• Skill level – Installation of this appliance requires basic mechanical skills.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not covered under the Warranty.
• Remove all tape and packaging.
• Make sure the burners are properly seated and level.
• Take the accessory pack out of the oven and/or drawer.
• Check to be sure that no range parts have come loose during shipping.
INSTALLATION INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INST ALLATION
IN THE COMMONWEALTH OF MASSACHUSETTS
• This product must be installed by a licensed plumber or gas fitter.
• When using ball type gas shut-off valves, they shall be the T-handle type.
• A flexible gas connector, when used, must not exceed 3 feet in length.
FOR YOUR SAFETY
Do not store or use combustible materials, gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
If you smell gas:
1.
2. Don’t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier from a
PREPARING FOR INSTALLATION
TOOLS YOU WILL NEED
MATERIALS YOU MAY NEED
• Gas line shut-off valve
• Pipe joint sealant or UL-approved pipe thread tape with Teflon* that resists action of natural and LP gases
• Flexible metal appliance connector (1/2 A 5-foot length is r installation but other lengths are acceptable. Never use an old connector when installing a new range.
• Flare union adapter for connection to gas supply line (3/4
• Flare union adapter for connection to pressure r
Liquid leak detector or soapy water
• Lag bolt or 1/2 concrete floors only).
Open windows.
neighbor’s home or from a cell phone outside of the home.
I.D.)
ecommended for ease of
or 1/2NPT x 1/2I.D.)
egulator on range (1/2
O.D. sleeve anchor (for
* Teflon: Registered trademark of DuPont
NPT x 1/2I.D.)
.
2
INSTALLATION INSTRUCTIONS
INSTALLATION SAFETY INSTRUCTIONS
WARNING: Read these instructions completely and carefully. Improper
installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, manufacturer (dealer) or the gas supplier.
Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use NEW flexible connectors when installing a gas appliance.
IMPORTANT: Remove all packing material and literature from oven before connecting gas and electrical supply to range.
• Have your range installed by a qualified
installer.
• Your range must be electrically grounded
in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes. See this manual.
• Before installing your range on linoleum or any
other synthetic floor covering, make sure the floor covering can withstand 180°F without shrinking, warping or discoloring. Do not install the range over carpeting unless a sheet
thick plywood or similar insulator is
of 1/4 placed between the range and carpeting.
• Make sure the wall coverings around the
range can withstand heat generated by the range up to 200°F.
void placing cabinets above the range. T
A
reduce the hazard caused by reaching over the open flames of operating burners, install a ventilation hood over the range that pr forward at least 5 cabinets.
• The ventilating hood must be constructed of
sheet metal not less than 0.0122 above the cooktop with a clearance of not less than 1/4 of the combustible material or metal cabinet. The hood must be at least as wide as the appliance and centered over the appliance. Clearance between the cooking surface and the ventilation hood surface
between the hood and the underside
Electrical Connections in
o
ojects
beyond the front of the
thick. Install
MUST NEVER
BE LESS THAN 24 INCHES
EXCEPTION: Installation of a listed microwave
oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.
• If cabinets are placed above the range, allow a minimum clearance of 30 the cooking surface and the bottom of unprotected cabinets.
• If a 30
• The vertical distance from the plane of the
CAUTION: Items of inter
clearance between cooking surface and overhead combustible material or metal cabinets cannot be maintained, protect the underside of the cabinets above the cooktop with not less than 1/4 covered with sheet metal not less than
0.0122 surface and protected cabinets
BE LESS THAN 24 INCHES
cooking surface to the bottom of adjacent overhead cabinets extending closer than 1 the plane of the range sides must not be less than 18 illustration in this manual.)
children should not be stored in cabinets above a range or on the backsplash of a range—children climbing on the range to reach items could be seriously injured.
thick. Clearance between the cooking
. (See the Dimensions and Clearances
insulating millboard
CAUTION: Do not attempt to
operate the oven of this range during a power failure.
.
between
MUST NEVER
.
to
est to
3
INSTALLATION INSTRUCTIONS
DIMENSIONS AND CLEARANCES
Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for safe use of your range. The location of the electrical outlet and pipe opening (see
Locations
requirements.
) may be adjusted to meet specific
Gas Pipe and Electrical Outlet
INSTALLATION CLEARANCES
The range may be placed with 0 (flush) at the back wall.
clearance
DIMENSIONS
4
ANTI-TIP DEVICE
WARNING!
All ranges can tip and injury could result. To prevent accidental tipping of the range, attach an approved Anti-Tip device to the wall. (See Installing the Anti-Tip Device in this manual.) To check if the device is installed and engaged properly, carefully tip the range forward. The Anti-Tip device should engage and prevent the range from tipping over.
LOCATION
INSTALLATION INSTRUCTIONS
If you pull the range out from the wall for any reason, make sure the Anti-Tip device is engaged when you push the range back against the wall.
Do not locate the range where it may be subject to strong drafts. Any openings in the floor or wall behind the range should be sealed. Make sure the openings around the base of the range that supply fresh air for combustion and ventilation are not obstructed by carpeting or woodwork.
Your range, like many other household items, is heavy and can settle into soft floor coverings such as cushioned vinyl or carpeting. Use care when moving the range on this type of flooring. It is recommended that the following simple and inexpensive instructions be followed to protect your floor.
The range should be installed on a sheet of plywood (or similar material). When the floor covering ends at the front of the range, the area that the range will rest on should be built up with plywood to the same level or higher than the floor covering. This will allow the range to be moved for cleaning or servicing.
Also, make sure your floor covering will withstand 180°F. (See the
Instructions
Make sure the wall coverings around your range can withstand the heat generated (up to 200°F) by the range. (See the
Instructions
section.)
section.)
Installation Safety
Installation Safety
5
INSTALLATION INSTRUCTIONS
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
1. PROVIDE ADEQUATE GAS SUPPLY
Your range is designed to operate at a pressure of 5 gas or, if designed for LP gas (propane or butane), 10
Make sur type of gas for which it is designed.
This range is convertible for use on natural or propane gas. If you decide to use this range on LP gas, conversion must be made by a qualified LP installer befor range on that gas.
oper operation, the pressure of natural gas
For pr supplied to the regulator must be between 5 and 13of water column.
For LP gas, the pressure supplied must be
of water column on natural
of water column.
e you ar
e supplying your range with the
e attempting to operate the
between 10 When checking for proper operation of the
egulator, the inlet pressure must be at least 1
r
eater than the operating (manifold) pr
gr as given above.
The pressure regulator located at the inlet of the range manifold must remain in the supply line regardless of whether natural or LP gas is being used.
A flexible metal appliance connector used to connect the range to the gas supply line should have an I.D. of 1/2 ease of installation. In Canada, flexible connectors must be single wall metal connectors no longer than 6 feet in length.
6
and 13of water column.
and be 5 feet in length for
essur
e
INSTALLATION INSTRUCTIONS
2. CONNECT THE RANGE TO GAS
Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on.
Because hard piping restricts movement of the range, the use of a CSA International-certified flexible metal appliance connector is recommended unless local codes require a hard-piped connection.
Never use an old connector when installing a new range. If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made.
To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon*
around, all male (external) pipe threads.
A
Install a manual gas line shut-off valve in the gas line in an easily accessed location outside of the range. Make sur operating the range knows where and how to shut off the gas supply to the range.
B
Install male 1/2
NPT internal thread at inlet of regulator.
1/2 Use a backup wrench on the regulator fitting to avoid damage. When installing the range from the front, remove the 90° elbow for easier installation.
flare union adapter to the
e everyone
C
Install male 1/2 to the NPT internal thread of the manual shut-off valve, taking care to back-up the shut-off valve to keep it from turning.
D
Connect flexible metal appliance connector to the adapter on the range. Position range to permit connection at the shut-off valve.
E
When all connections have been made, make sure all range controls are in the off position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system.
or 3/4flare union adapter
WARNING!
DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.
When using test pressures greater than 1/2 psig
essure test the gas supply system of the
to pr residence, disconnect the range and individual shut-off valve from the gas supply piping. When using test pressures of 1/2 psig or less to test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve.
* Teflon: Registered trademark of DuPont
FLEXIBLE CONNECTOR HOOKUP
See page 8 for rigid pipe hookup options.
7
INSTALLATION INSTRUCTIONS
RIGID PIPE HOOKUP OPTIONS
PREFERRED CONNECTION
ALTERNATE CONNECTION
3. ELECTRICAL CONNECTIONS
ELECTRICAL REQUIREMENTS
120-volt, 60 Hertz, properly grounded dedicated circuit protected by a 15-amp or 20-amp circuit breaker or time delay fuse.
EXTENSION CORD CAUTIONS
Because of potential safety hazards associated with certain conditions, we str against the use of an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a UL-listed,
ounding-type appliance extension cor
e gr
3-wir and that the current carrying rating of the cord in amperes be equivalent to, or greater than,
cuit rating.
the cir
ongly r
ecommend
d
GROUNDING
IMPORTANT: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY
PREFERRED METHOD
8
GROUNDED.
The power cord of this appliance is equipped with a three-prong (grounding) plug which mates with a standard three-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance.
The customer should have the wall r and circuit checked by a qualified electrician to
eceptacle is properly grounded.
make sur Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD.
A wor or recommended for gas range receptacles.
Ground Fault Circuit Interrupters (GFCI’s) are devices that sense leakage of current in a circuit and automatically switch off power when a threshold leakage level is detected. These devices must be manually reset by the consumer. The National Electrical Code requires the use of GFCI’s in kitchen receptacles installed to serve countertop surfaces. Performance of the range will not be affected if operated on a GFCI-pr
e the r
d about GFCI’
otected circuit but occasional nuisance
s – GFCI’
s ar
eceptacle
e not r
equir
ed
INSTALLATION INSTRUCTIONS
3. ELECTRICAL CONNECTIONS (continued)
A. USAGE SITUATIONS WHERE THE
APPLIANCE POWER CORD WILL BE DISCONNECTED INFREQUENTLY
TEMPORARY METHOD
(Adapter plugs not permitted in Canada)
An adapter may be used only on a 15-amp circuit. Do not use an adapter on a 20-amp circuit. Where local codes permit, a TEMPORARY CONNECTION may be made to a properly grounded two-prong wall receptacle by the use of a UL-listed adapter, available at most hardware stores.
The larger slot in the adapter must be aligned with the larger slot in the wall receptacle to provide proper polarity in the connection of the power cord.
When disconnecting the power cord from the adapter, always hold the adapter with one hand. If this is not done, the adapter ground terminal is very likely to br this happen, DO NOT USE the appliance until a proper ground has again been established.
eak with r
epeated use. Should
B. USAGE SITUATIONS WHERE THE
APPLIANCE POWER CORD WILL BE DISCONNECTED FREQUENTLY
Do not use an adapter plug in these situations because disconnecting of the power cord places undue strain on the adapter and leads to eventual failure of the adapter ground terminal. The customer should have the two-prong wall receptacle replaced with a three-prong (grounding) receptacle by a qualified electrician before using the appliance.
The installation of appliances designed for mobile home installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or, when such standard is not applicable, the Standard for Manufactured Home Installations, latest edition (Manufactured Home Sites, Communities and Set-Ups), ANSI A225.1, latest edition, or with local codes. In Canada, mobile home installation must be in accordance with the current CAN/CSA Z240/MH Mobile Home Installation Code.
ELECTRICAL DISCONNECT
Locate disconnect plug on the range back.
A
Pinch sides of connector and pull out of
B
range back.
CAUTION
Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded through the house wiring. The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded.
9
Loading...