LG F242CD, F122HD, F122CD, F182CD INSTALLATION MANUAL

ENGLISH
LG Multi Air Conditioner
INSTALLATION MANUAL
LG
website http://www.lgservice.com
• Please read this instruction manual completely before installing the product.
• When the power cord is damaged, replacement should be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it thoroughly.
ESPAÑOL
2 Multi Air Conditioner
Multi Air Conditioner Installation Manual
TABLE OF CONTENTS
Safety Precautions............................3
Introduction ........................................8
Symbols used in this manual..........8
Features ...........................................8
Installation ..........................................9
Selection of the best location..........9
Piping Length and Elevation...........9
Drill a Hole in the Wall...................10
Flaring Work...................................10
The Indoor Unit Installation...........12
Checking the Drainage .................15
Wired Remote Controller
Installation ......................................16
Connecting the Cables..................18
Optional Operation ........................21
Connecting cable
Pipes: Gas side
Liquid side
Insulation materials
Additional drain pipe
Level gauge
Screw driver
Electric drill
Hole core drill(ø70mm)
Flaring tool set
Specified torque wrenches
1.8kg.m, 4.2kg.m, 5.5kg.m,
6.6kg.m (different depending on model No.)
Spanner ........................Half union
A glass of water
Screw driver
Hexagonal wrench(4mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Installation
Requirements
Required Parts Required Tools
Installation Manual 3
ENGLISH
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
Installation
Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.
• There is risk of fire or electric
shock.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
• Do not disassemble or repair the product. There is risk of fire or electric shock.
Always ground the product.
• There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
• There is risk of fire or electric shock.
Always install a dedicated circuit and breaker.
• Improper wiring or installation may cause fire or electric shock
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
4 Multi Air Conditioner
Safety Precautions
Do not modify or extend the power cable.
• There is risk of fire or electric shock.
Do not install, remove, or re­install the unit by yourself (customer).
• There is risk of fire, electric shock, explosion, or injury.
Be cautious when unpacking and installing the product.
• Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.
For installation, always contact the dealer or an Authorized Service Center.
• There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand.
• It may cause injury, accident, or damage to the product.
Be sure the installation area does not deteriorate with age.
• If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Operation
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open
.
• Moisture may condense and wet or damage furniture.
Take care to ensure that power cable could not be pulled out or damaged during operation.
• There is risk of fire or electric shock.
Do not place anything on the power cable.
• There is risk of fire or electric shock.
Do not plug or unplug the power supply plug during operation.
• There is risk of fire or electric shock.
Do not touch(operate) the product with wet hands.
• There is risk of fire or electrical shock.
Do not place a heater or other appliances near the power cable.
• There is risk of fire and electric shock.
Installation Manual 5
ENGLISH
Safety Precautions
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.
• Do not use the telephone or turn switches on or off. There is risk of explosion or fire
If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable.
• There is risk of electric shock or fire.
Stop operation and close the window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives.
• There is risk of property damage, failure of product, or electric shock.
Do not allow water to run into electric parts.
• It may cause There is risk of fire, failure of the product, or electric shock.
Do not store or use flammable gas or combustibles near the product.
• There is risk of fire or failure of product.
Do not use the product in a tightly closed space for a long time.
• Oxygen deficiency could occur.
Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
• There is risk of physical injury, electric shock, or product failure.
When the product is soaked (flooded or submerged), contact an Authorized Service Center.
• There is risk of fire or electric shock.
Be cautious that water could not enter the product.
• There is risk of fire, electric shock, or product damage.
Ventilate the product from time to time when operating it together with a stove, etc.
• There is risk of fire or electric shock.
Turn the main power off when cleaning or maintaining the product.
• There is risk of electric shock.
Gasolin
6 Multi Air Conditioner
Safety Precautions
Installation
Always check for gas (refrigerant) leakage after installation or repair of product.
• Low refrigerant levels may cause failure of product.
Install the drain hose to ensure that water is drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the product.
• To avoid vibration or water leakage.
Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.
• It may cause a problem for your neighbors.
Use two or more people to lift and transport the product.
• Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation
.
Do not expose the skin directly to cool air for long periods of time. (Don't sit in the draft.)
• This could harm to your health.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.
• There is risk of damage or loss of property.
When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker.
• There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody could step on or fall onto the outdoor unit.
• This could result in personal injury and product damage.
Operation
90°
Safety Precautions
Installation Manual 7
ENGLISH
Do not block the inlet or outlet of air flow.
It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter.They are very sharp!
There is risk of personal injury.
Do not step on or put anyting on the product. (outdoor units)
There is risk of personal injury and failure of product.
Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
Do not insert hands or other objects through the air inlet or outlet while the product is operated.
There are sharp and moving parts that could cause personal injury.
Do not drink the water drained from the product.
It is not sanitary and could cause serious health issues.
Use a firm stool or ladder when cleaning or maintaining the product.
Be careful and avoid personal injury.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.
There is risk of fire or explosion
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
They may burn or explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.
The chemicals in batteries could cause burns or other health hazards.
Wax
Thinner
8 Multi Air Conditioner
Introduction
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the air conditioner.
This symbol indicates special notes.
NOTICE
Introduction
Symbols used in this Manual
Features
Air Intake Vents
Air Outlet Vents
Connecting Wires
Piping
Drain Hose
Base Plate
Air Outlet
Air Intake
(side, rear)
Connection pipe Drain hose
Connecting wire
Control cover
Air filters
Air outlet vents
Air intake vents
Remote Controller
Installation Manual 9
ENGLISH
Installation
Installation
Selection of the best location
The place shall easily bear a load exceeding four times the indoor unit’s weight.
The place shall be able to inspect the unit as the figure.
The place where the unit shall be leveled.
The place shall allow easy water
drainage.(Suitable dimension “H” is necessary to get a slope to drain as figure.)
The place shall easily connect with the outdoor unit.
The place where the unit is not affected by an electrical noise.
The place where air circulation in the room will be good .
There should not be any heat source or steam near the unit
Piping Length and Elevation
Total(A+B+C) 30 30 45 45
Max/Room(A/B/C) 15 15 15 15
Standard length 7.5 7.5 7.5 7.5
In-Out(h1) 7.5 7.5 7.5 7.5
In-In(h2) 7.5 7.5 7.5 7.5
Additional
20 20 20 20
Refrigerent(g/m)
Piping Length (m)
F242CX
F362CX F363CX
F483CX
F242HX F483HX
h1
h2
A
B
h1
h2
A
B
C
Top view
(unit: mm)
Front view
Inspection hole
(600X600)
Control box
1000
Front
600600
H
10 Multi Air Conditioner
Installation
Drill the piping hole with a ø70mm hole core drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side.
Drill a Hole in the Wall
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
Flaring Work
Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure.
Cut the pipes and the cable.
1. Use the piping kit accessory or the pipes purchased locally.
2. Measure the distance between the indoor and the outdoor unit.
3. Cut the pipes a little longer than measured distance.
4. Cut the cable 1.5m longer than the pipe length.
Burrs removal
1. Completely remove all burrs from the cut cross section of pipe/tube.
2. Put the end of the copper tube/pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing.
Putting nut on
Remove flare nuts attached to indoor and
outdoor unit, then put them on pipe/tube having completed burr removal. (not possible to put them on after flaring work)
Copper
pipe
90°
Slanted Uneven Rough
Pipe
Reamer
Point down
Flare nut
Copper tube
Installation Manual 11
ENGLISH
Installation
Flaring work
1. Firmly hold copper pipe in a bar in the dimension shown in the table below.
2. Carry out flaring work with the flaring tool.
Bar
Copper pipe
Clamp handle
Red arrow mark
Cone
Yoke
Handle
Bar
"A"
Check
1. Compare the flared work with the figure by.
2. If a flared section is defective, cut it off and do flaring work again.
Slanted
Inside is shiny without scratches
Smooth all round
Even length
all round
Surface
damaged
Cracked Uneven
thickness
= Improper flaring =
mm inch mm
Ø6.35 1/4 1.1~1.3 Ø9.52 3/8 1.5~1.7
Ø12.7 1/2 1.6~1.8 Ø15.88 5/8 1.6~1.8 Ø19.05 3/4 1.9~2.1
Outside diameter A
12 Multi Air Conditioner
Installation
The Indoor Unit Installation
Apply a joint-canvas between the unit and duct to absorb unnecessary vibration.
Apply a filter Accessory at air return hole.
Install the unit leaning to a drainage hole
side as a figure for easy water drainage.
A place where the unit will be leveled and that can support the weight of the unit.
A place where the unit can withstand its vibration.
A place where service can be easily performed.
CASE 1
POSITION OF SUSPENSION BOLT
CASE 2
POSITION OF CONSOLE BOLT
(Unit:mm)
Drainage hole
M10 Nut
M10 SP. washer
M10 washer
X 4
X 4
(Local supply)
X 4
M10 Nut
M10 SP. washer
M10 washer
X 4
X 4
(Local supply)
X 4
A
B
C
1-3 mm
D
(G)
H
I
EF
J
A B C D E F (G) H I J
12k/18k/24k
932 880 355 45.5 450 30 87 750 163 260
Btu/h
Dimension
Capacity
Installation Manual 13
ENGLISH
Installation
Select and mark the position for fixing bolts.
Drill the hole for set anchor on the face of ceiling.
Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling.
Mount the suspension bolts to the set anchor firmly.
Secure the installation plates onto the suspension bolts (adjust level roughly) using nuts, washers and spring washers.
1 Set anchor
Old building New building
2 Plate washer 3 Spring washer
4 Nut
5 Suspension bolts
Tighten the nut and bolt to prevent unit falling
Local supply Set anchor Plate washer - M10 Spring washer - M10 Nut - W3/8 or M10 Suspension bolt - W3/8 or M10
14 Multi Air Conditioner
Installation
Ceiling
CAUTION
1~3mm
Drainage hole
Drainage hole
U-Trap
B
C
A 70mm B 2C C 2 x SP SP = External Pressure
(mmAq)
Ex) External Pressure
= 10mmAq A 70mm B 40mm C 20mm
A
Make sure to be closed.
Unit
Drainage pipe (Local supply)
Thermal insulator
(Local supply)
Drainage hole
CAUTION FOR GRADIENT OF UNIT AND DRAIN PIPING
Lay the drain hose with a downward inclination so water will drain out.
Front of view
Always lay the drain with downward inclination (1/50 to 1/100). Prevent any upward flow or reverse flow in any part.
5mm or thicker formed thermal insulator shall always be provided for the drain pipe.
Install the P-Trap (or U-Trap) to prevent a water leakage caused by the blocking of intake air filter.
Applied U-Trap Dimension
1. Install declination of the indoor unit is very important for the drain of the duct type air conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 5mm.
The unit must be horizontal or declined to the drain hose connected when finished
installation.
CORRECT
CORRECT
INCORRECT
INCORRECT
Upward routing not allowed
Installation Manual 15
ENGLISH
Installation
INSULATION, OTHERS
Insulate the joint and tubes completely.
All thermal insulation must comply with local requirement.
INDOOR UNIT
REFRIGERANT PIPE
Insulate and tape both the gas piping and liquid piping.
THERMAL INSULATION
Make sure that there is no clearance here.
Overlap with thermal insulator for piping.
Thermal insulator for refrigerant pipe (Local supply)
Thermal insulator for piping(Local supply)
Hose clip for thermal insulator(Local supply)
Union for liquid pipe
Refrigerant pipe and thermal insulator(Local supply)
Union for gas pipe
Thermal insulator for refrigerant pipe (Local supply)
Hose clip for thermal insulator (Local supply)
Power cable
Liquid pipe
Thermal insulator
Gas pipe
Tape
Checking the Drainage
1) Checking the Drainage
1. Remove the Air Filter.
2. Check the drainage.
Spray one or two glasses of water upon the evaporator.
Ensure that water flows drain hose of indoor unit without any leakage.
Common direction of drain and piping. Tape the tubing, drain hose and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit.
If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors. *Foamed polyethylene or equivalent is recommended.
NOTICE
NOTICE
Wired Remote Controller Installation
16 Multi Air Conditioner
Installation
Remote control
box body
Cord clamp (accessory)
Lever carefully
the box open
using a screw
driver, etc.
Front case
The lower part
Face of wall
Under plate
Screw (accessory)
Fix the under plate on the wall
Separate the under plate from Remote control box.
Fix the cord clamps on the wall by ø 3 tapping screws (accessory).
Fix the remote control cord.
DISASSEMBLING
ELECTRICAL WIRING
Wire and make sure that terminal
numbers are matched on unit side and
remote controller side.
The maximum length of the cord is 100m.
If the length of the cord exceeds 50m,
use a wire size greater than 0.5mm
2
.
Remote controller
(Main board)
CN REMO
Installation
Installation Manual 17
ENGLISH
WIERED REMOTE CONTROLLER INSTALLATION
Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature. Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller LED's, the remote controller should be installed properly as shown in Fig.1. (The standard height is 1.2~1.5 m from floor level.)
Operation unit
ZONE
1234
Humidify
JET
AUTO
AUTO SWINGOPERATION
FAN SPEED
Program set
SUB FUNCTION
SET TEMP
Room Temp
HI MED LO
Heater Defrost Filter
Preheat
Out door
Time
Timer
On Set no.Time
Off
0103 0507 09 1113 1517 19 2123
O
p
e
ra
t
io
n
u
n
it
Z
O
N
E
1
2
34
H
um
idify
JET
AUTO
A
U
T
O
S
W
I
N
G
O
P
E
R
A
T
IO
N
F
A
N
S
P
E
E
D
P
r
o
gr
a
m
s
e
t
S
U
B FU
NC
TIO
N
S
E
T
T
E
M
P
R
o
o
m
T
e
m
p
H
I
M
E
D
LO
H
eater
D
efrost
F
ilter
P
reh
ea
t
O
ut door
T
im
e
T
im
e
r
O
n
S
e
t
n
o
.
T
im
e O
f
f
0
1
0
3
0
5
0
7
0
9
1
1
1
3
1
5
1
7
1
9
2
1
2
3
5feet
(1.5meters)
no
no
no
yes
Operation unit
ZONE
1234
Humidify
JET
AUTO
AUTO SWING OPERATION
FAN SPEED
Program set
SUB FUNCTION
SET TEMP
Room Temp
HI MED LO
Heater Defrost Filter
Preheat
Out door
Time
Timer
On Set no.Time
Off
0103 0507 09 1113 1517 19 2123
Fig.1 Typical locations for remote controller
18 Multi Air Conditioner
Installation
Indoor
Connect the cable to the indoor unit by connecting the wires to the terminals on the control board individually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No. are the same as those of the indoor unit.)
Connecting the Cables
The above circuit diagram is subject to change without notice.
The earth wire should be longer than the common wires.
When installing, refer to the circuit diagram behind the panel front of the indoor unit.
Connect the wires firmly so that they may not be pulled out easily.
Connect the wires according to color codes, referring to the wiring diagram.
If a power plug is not used, provide a circuit breaker between power source and the unit as shown by.
The power cord connected to the outdoor unit should be complied with the following specifications (UL, ETL recognized or CSA certified).
The power connecting cable connected to the indoor and outdoor unit should be complied with the following specifications.
Air
Conditioner
Main power source
Circuit Breaker Use a circuit breake or time delay fuse.
0.75
Cable Type(B) H07RN-F
NORMAL CROSS
-SECTIONAL AREA
Grade
(mm2)
F242CX/HX F363CX
F362CX
F483CX/HX
2.5 3.5 4
Cable Type(B) H07RN-F H07RN-F H07RN-F
NORMAL CROSS
-SECTIONAL AREA
Grade
(mm2)
GN/YL
20mm
AWG18
GN/YL
20mm
Installation Manual 19
ENGLISH
Installation
Outdoor
1. Remove the control cover from the unit by loosening the screw. Connect the wires to the terminals on the control board individually.
2. Secure the cable onto the control board with the cord clamp.
3. Refix the control cover to the original position with the screw.
4. Use a recognized circuit breaker between the power source and the unit. A disconnecting device to adequately disconnect all supply lines must be fitted.
Terminal block
Over 5mm
Cover control
Connecting cable
Power cord
Holder for
power supply
cord
Outdoor Unit
According to the confirmation of the above conditions, prepare the wiring as follows.
1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover.
2. The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3. Specification of power source.
4. Confirm that electrical capacity is sufficient.
5. See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.
6. Confirm that the cable thickness is as specified in the power source specification. (Particularly note the relation between cable length and thickness.
7. Always install an earth leakage circuit breaker in a wet or moist area.
8. The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal function of the overload.
9. The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active(phase) conductors.
F242CX
F362CX F363CX
F483CX
F242HX F483HX
25A 35A 35A 50A
Circuit
Breaker(A)
Grade
20 Multi Air Conditioner
Installation
Connection of the cable
1. Remove the cover control from the unit by loosening the screw. Connect the wires to the terminals on the control board individually as the following.
2. Secure the cable onto the control board with the holder (clamper).
3. Refix the cover control to the original position with the screw.
4. Use a recongnized circuit breaker between the power source and the unit. A disconnection device to ade-quately disconnect all supply lines must be fitted.
F242CX/F242HX,F362CX
Terminal on the OUTDOOR UNIT
1(L) 1(L)2(N) 2(N) 3(A) 3(B)
1(L) 2(N)
POWER SUPPLY
1(L) 2(N) 3 4
Terminal on the INDOOR UNIT
A Unit
1(L) 2(N) 3 4
Terminal on the INDOOR UNIT
B Unit
F363CX
Terminal on the OUTDOOR UNIT
1(L) 1(L)2(N) 2(N)2(N) 3(A) 3(B) 3(C)1(L)
1(L) 2(N)
POWER SUPPLY
1(L) 2(N) 3 4
Terminal on the INDOOR UNIT
A Unit
1(L) 2(N) 3 4
Terminal on the INDOOR UNIT
B Unit
1(L) 2(N) 3 4
Terminal on the INDOOR UNIT
C Unit
F483CX/F483HX
Terminal on the OUTDOOR UNIT
L N
1(L) 2(N)
POWER SUPPLY
1(L) 2(N) 3 4
Terminal on the INDOOR UNIT
A Unit
Terminal on the OUTDOOR UNIT
1(L) 3(A) 3(B) 3(C)2(N) 1(L) 2(N)
1(L) 2(N) 3 4
Terminal on the INDOOR UNIT
B Unit
1(L) 2(N) 3 4
Terminal on the INDOOR UNIT
C Unit
Installation Manual 21
ENGLISH
Installation
1. Two Thermistor System
(1) Open the rear cover of the wired remote-controller to set the mode.
(2) Select one of three selectable modes as follows.
Position 1: The room temperature is controlled by the thermistor of the main body.
Position 2: The room themperature is controlled by the thermistor of the wired remote-
controller, control the temperature according to the position of wired remote­controller.
Position 3: The room temperature is controlled by lower temperature between the temperature of main body and of remote-controller sensor.
(3) Move the slide switch to set position.
(4) Close the rear cover and check if it works normally.
CAUTION
:
Select the position after counselling with a customer.
In case of cooling mode, room temperature is controlled by the main body sensor.
To control the room temperature by a wired remote controller, install controller(room
temp. sensor) to sense the temperature more accurately.
Manufactured in the position 3.
TH
R14H
SW TH
REMO MAIN 2TH
OP7 R18H
R17H
OP6
LO
STAND
SW HIGH
HI
R03S
C070
R04S
R02S
R01S
OP3
OP2 OP1
R19H
R11H
R13H R12H
OP5R16H OP4
R15H
CO1H
REMO
Room Temp. sensor
2TH
MAIN
Position 2 Position 1 Position 3
Zone State/Default E.S.P
Slide switch for 2 Thermistor
Optional Operation
22 Multi Air Conditioner
Installation
2. E.S.P.(External Static Pressure) Setting
(1) Open the rear cover of the wired remote-controller to set the mode. (2) Select one of three selectable modes as follows.
Without Zone System
1. Position V-H, F-H:
This position sets the maximum E.S.P as a default set.
2. Position V-L:
This position sets the minimum E.S.P as a default set.
With Zone System
1. Position V-H:
Maximum E.S.P setting & Fan speed is varied according to the state of dampers by micom.
2. Position F-H:
Maximum E.S.P setting & Fan speed doesn't vary according to the opening & Closing of dampers.
3. Position V-L:
Minimum E.S.P setting & Fan speed is varied according to the state of dampers by micom.
* Maximum : 4 mmAq
Minimum : 0 mmAq
(3) Move the slide switch to set position.
(4) Close the rear cover and check if it works normally.
TH
R14H
SW TH
REMO MAIN 2TH
OP7 R18H
R17H
OP6
LO
STAND
SW HIGH
HI
R03S
C070
R04S
R02S
R01S
OP3
OP2 OP1
R19H
R11H
R13H R12H
OP5R16H OP4
R15H
CO1H
V-L
V-H
F-H
Select the position after checking duct work and E.S.P of the unit.
Maunfactured in the position F-H.
CAUTION:
Installation Manual 23
ENGLISH
Installation
3. How to Set E.S.P?
Preheat
ZONE
Operation unit Program set
Room Temp
MED LO
AUTO JET
Heater Defrost Filter
Humidify Out door
Timer
On Set no. Time
Off
01 03 05 07 09 11 13 15 17 19 21 23
1234
OPERATION
FAN SPEED
SUB FUNCTION
SET TEMP
HI
AUTO SWING
Time
Preheat
ZONE
Operation unit Program set
Room Temp
MED LO
AUTO JET
Heater Defrost Filter
Humidify Out door
Timer
On Set no. Time
Off
01 03 05 07 09 11 13 15 17 19 21 23
1234
OPERATION
FAN SPEED
SUB FUNCTION
SET TEMP
HI
AUTO SWING
Time
Time
SUB FUNCTION
SET TEMP
OPERATIONAUTO SWING
Preheat
ZONE
Operation unit Program set
Room Temp
MED LO
AUTO JET
Heater Defrost Filter
Humidify Out door
Timer
On Set no. Time
Off
01 03 05 07 09 11 13 15 17 19 21 23
1234
FAN SPEED
HI
2
Time
SUB FUNCTION
SET TEMP
OPERATIONAUTO SWING
Preheat
ZONE
Operation unit Program set
Room Temp
MED LO
AUTO JET
Heater Defrost Filter
Humidify Out door
Timer
On Set no. Time
Off
01 03 05 07 09 11 13 15 17 19 21 23
34
FAN SPEED
HI
1
Timer
1
2
3
5
4
Timer
Procedure of RPM change:
Ex) External Static pressure is 4mmAq for 24k.
To protect the unit, compressor is designed to be off during E.S.P. setting.
Push the "On/Off" button. The unit will start.
Push the "Timer" and "Wind" button simultaneously for more then 3 seconds.
Push the "Up" of "Down" button for E.S.P adjustment. And, adjust the number which you want.(In this example, the number is "138". Refer to the table 1 on the next page.)
Shift the fan speed mode by pressing the fan speed button. And then, Adjust numbers of next steps by repeating the stage 3. (In this example, the numbers are "149" and "169" respectly)
Push the "Timer" and "Wind" button simultaneously for more than 3 seconds. Then, Wind Data is memorized by the EEPROM of the main PCB.
Note: The range of selection is from 1~255. Since, the display is two Digit only.
If the range selection is above 100 then the third digit will appear in the screen as shown.
24 Multi Air Conditioner
Installation
[Table. 1]
: 1. Be sure to set the value refering table 1. Unexpected set value will cause
mal-function.
2.Table 1 is based at 220V. According to the fluctuation of voltage, air flow rate varies.
NOTICE
Static Pressure(mmAq)
Setting Value
01234
Model Name Step(Hi/Med/Lo)
12.5 CMM 225 223 220 210 180
12k 10 CMM 242 240 238 236 235
8.5 CMM 251 250 249 248 247
16.5 CMM 165 161 158 156 153
18k 14.5 CMM 182 178 174 170 168
13 CMM 195 190 186 183 180 18 CMM 147 145 143 140 138
24k 16.5 CMM 159 156 153 152 149
14 CMM 180 177 174 171 169
P/No.: MFL35865802