LG DLGX7188RM User Manual [en, es]

1-800-243-0000
Or visit us on the Web at: us.lge.com
TM
TROMM DRYER
wi th Stea m
US ER’S GU ID E &
IN STALL ATION I NS TRUCTION S
Before beginning installation, read these
instructions carefully. This will simplify installation
and ensure that the dryer is installed correctly and
safely. Leave these instructions near the dryer
after installation for future reference.
SECADORA TROMM
co n vapór
GU ÍA DEL US UAR IO E
Número telefónico de LG Electronics, las 24 horas del día, 7 días a la semana:
1-800-243-0000
O visítenos en la Web en: us.lge.com
TM
IN STRUCCIO NE S DE IN STALAC IÓN
Antes de comenzar la instalación, lea atentamente estas instrucciones. Esto simplificará la instalación
y asegurará que la secadora está instalada
en forma correcta y segura. Conserve estas
instrucciones cerca de la secadora luego de la
instalación para futuras consultas.
Mod els/ Mode los
Electric/Eléctrica
DLEX7177WM DLEX7177RM
Gas/Gas
DLGX7188WM DLGX7188RM
P/No. 3828EL3010F
I N T ROD U C T I O N
2
IMPORTANT SAFETY INSTRUCTIONS
Basic Safety Precautions .......................................3
What to Do if You Smell Gas .................................. 4
Grounding Instructions ........................................... 5
Safety Instructions for Installation ...................... 5, 6
Safety Instructions for Steam Functions ................ 6
Safety Instructions for Connecting Electricity ....... 7
PARTS AND FEATURES
Special Features ..................................................... 8
Key Parts and Components ................................... 9
INSTALLATION INSTRUCTIONS
Choose the Proper Location ................................ 10
Clearances ........................................................... 10
Installation With Optional
Pedestal Base or Stacking Kit .............................. 11
Leveling the Dryer ................................................ 12
Reversing the Door Swing .................................... 12
Changing the Dryer Vent Location ....................... 13
Venting the Dryer ............................................ 14, 15
Connecting Gas Dryers .................................. 16, 17
Connecting Electric Dryers ............................. 18–22
Special Requirements for Manufactured
or Mobile Homes .................................................. 23
Final Installation Check .......................................23
Sorting Loads ....................................................... 24
Loading the Dryer ................................................. 24
Check the Lint Filter Before Every Load ............... 24
THANK YOU!
Congratulations on your purchase
and welcome to the LG family. Your
new LG Dryer combines the most
advanced drying sensor technology
with simple operation and high
efficiency. By following the
operating and care instructions
in this manual, your dryer will
provide you with many years of
reliable service.
HOW TO USE
Control Panel Features ......................................... 25
Cycle Guide .......................................................... 26
The Display ........................................................... 27
Operating the Dryer .............................................. 28
Cycle Setting Buttons .......................................... 29
Cycle Option Buttons .......................................... 29
Special Functions ................................................. 30
Custom Program .................................................. 31
Before Using The Steam Functions...................... 31
Steam Functions ............................................ 32, 33
Steam Cycle Guide .............................................. 33
USER-MAINTENANCE INSTRUCTIONS
Regular Cleaning .................................................. 34
TROUBLESHOOTING
Before Calling for Service ............................... 35–37
SPECIFICATIONS/OPTIONAL ACCESSORIES
Key Dimensions and Specifications ..................... 38
Optional Accessories ........................................... 38
Pedestal Installation ....................................... 39, 40
Stacking Kit Installation .................................. 41, 42
Product Registration Information
Model: Serial Number: Date of Purchase:
The model and serial number can be located on the rating plate inside the front door.
WARRANTY ................................................... 43
I M P O RTAN T S A F E T Y I N S T RU C T I O N S
READ ALL INSTRUCTIONS BEFORE USE wWARNING For your safety, the information in this manual must be
followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.
Your Safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word DANGER or WARNING. These words mean:
wDANGER: You can be killed or seriously injured if you don’t immediately follow instructions. wWARNING: You can be killed or seriously injured if you don’t follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
BASIC SAFETY PRECAUTIONS
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
• Read all instructions before using the dryer.
• Before use, the dryer must be properly installed as described in this manual.
• Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
• Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
• Do not reach into the dryer if the drum or any other part is moving.
• Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
• Do not tamper with controls.
• Before the dryer is removed from service or discarded, remove the door to the drying compartment.
• Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.
• Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
• Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
• Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.
• The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.
• Do not install or store the dryer where it will be exposed to the weather.
• Always check the inside of the dryer for foreign objects.
• Clean lint screen before or after each load.
3
I M P O RTAN T S A F E T Y I N S T RU C T I O N S
4
READ ALL INSTRUCTIONS BEFORE USE wWARNING For your safety, the information in this manual must be
followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance or any other appliances.
• Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
1. Do not try to light a match or cigarette, or turn on any gas or electrical appliance.
2. Do not touch any electrical switches. Do not use any phone in your building.
3. Clear the room, building, or area of all occupants.
CALIFORNIA SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT
This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects, or other reproductive harm and requires businesses to warn customers of potential exposure to such substances.
Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde, and soot, caused primarily by the incomplete combustion of natural gas or LP fuels.
4. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions carefully.
5. If you cannot reach your gas supplier, call the fire department.
Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.
I M P O RTAN T S A F E T Y I N S T RU C T I O N S
READ ALL INSTRUCTIONS BEFORE USE
wWARNING For your safety, the information in this manual must be
followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance must be equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
wWARNING Improper
connection of the equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service
person if you are in doubt as to whether the appliance is properly grounded.
Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance must be connected to a grounded metal, permanent wiring system or an equipment­grounding conductor must be run with the circuit conductors and connected to the equipment­grounding terminal or lead on the appliance.
Electrical shock can result if the dryer is not properly grounded.
SAFETY INSTRUCTIONS FOR INSTALLATION
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
Properly ground dryer to conform with all governing codes and ordinances. Follow details in the installation instructions. Electrical shock can result if the dryer is not properly grounded.
Before use, the dryer must be properly
installed as described in this manual.
Electrical shock can result if the dryer is not properly grounded.
Install and store the dryer where it will not be
exposed to temperatures below freezing or exposed to the weather.
All repairs and servicing must be performed by an authorized servicer unless specifically recommended in this Owner’s Guide. Use only authorized factory parts. Failure to follow
this warning can cause serious injury, fire, electrical shock, or death.
To reduce the risk of electric shock, do not install the dryer in humid spaces. Failure to
follow this warning can cause serious injury, fire, electrical shock, or death.
Connect to a properly rated, protected,
and sized power circuit to avoid electrical overload. Improper power circuit can melt,
creating electrical shock and/or fire hazard.
Remove all packing items and dispose of all shipping materials properly. Failure to do so can result in death, explosion, fire, or burns.
Place dryer at least 18 in. above the floor for a garage installation. Failure to do so can result in death, explosion, fire, or burns.
Keep all packaging from children. Packaging material can be dangerous for children. There is a risk of suffocation.
5
I M P O RTAN T S A F E T Y I N S T RU C T I O N S
6
READ ALL INSTRUCTIONS BEFORE USE
wWARNING For your safety, the information in this manual must be
followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.
SAFETY INSTRUCTIONS FOR INSTALLATION
Exhaust/Ducting:
Gas dryers MUST be exhausted to the outside. Failure to follow these instructions
can result in fire or death.
The dryer exhaust system must be exhausted
to the outside of the dwelling. If the dryer is not exhausted outdoors, some fine lint and large amounts of moisture will be expelled into the laundry area. An accumulation of
lint in any area of the home can create a health and fire hazard.
Use only rigid metal or flexible metal 4-in.
diameter ductwork inside the dryer cabinet or for exhausting to the outside. Use of plastic or other combustible ductwork can cause a fire. Punctured ductwork can cause
a fire if it collapses or becomes otherwise restricted in use or during installation.
Ductwork is not provided with the dryer, and
you should obtain the necessary ductwork locally. The end cap should have hinged dampers to prevent backdraft when the dryer is not in use. Failure to follow these instructions
can result in fire or death.
The exhaust duct must be 4 in. (10 cm) in
diameter with no obstructions. The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer. Failure to follow
these instructions can result in fire or death.
Rigid or semi rigid metal ducting is
recommended for use between the dryer and the wall. In special installations when it is impossible to make a connection with the above recommendations, a UL­listed flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will affect drying time. Failure to follow these instructions can
result in fire or death.
DO NOT use sheet metal screws or other
fasteners which extend into the duct that could catch lint and reduce the efficiency of the exhaust system. Secure all joints with
duct tape. For complete details, follow the Installation Instructions. Failure to follow these instructions can result in fire or death.
SAFETY INSTRUCTIONS FOR STEAM FUNCTIONS
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
Do not open the dryer door during steam cycles. Failure to follow these instructions can result in a burn hazard.
Do not dry articles that have been previously
cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
Failure to follow these instructions can result in fire or death.
• Do not fill the steam feeder with gasoline, dry-cleaning solvents, or other flammable or explosive substances. Failure to follow these
instructions can result in fire or death.
Do not touch the steam nozzle in the drum during or after the steam cycle. Failure to follow these instructions can result in a burn hazard.
Do not fill the steam feeder with hot water (over 86° F / 30° C). Failure to follow these instructions can result in a burn hazard.
I M P O RTAN T S A F E T Y I N S T RU C T I O N S
READ ALL INSTRUCTIONS BEFORE USE
wWARNING For your safety, the information in this manual must be
followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.
SAFETY INSTRUCTIONS FOR CONNECTING ELECTRICITY
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
Do not, under any circumstances, cut or
remove the ground prong from the power cord. To prevent personal injury or damage to
the dryer, the electrical power cord must be plugged into a properly grounded outlet.
For personal safety, this dryer must be properly grounded. Failure to do so can result in electrical shock or injury.
Refer to the installation instructions in this
manual for specific electrical requirements for your model. Failure to follow these
instructions can create an electrical shock hazard and/or a fire hazard.
This dryer must be plugged into a properly
grounded outlet. Electrical shock can result if the dryer is not properly grounded. Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded. Failure to follow these instructions
can create an electrical shock hazard and/or a fire hazard.
The dryer should always be plugged into
its own individual electrical outlet which has a voltage rating that matches the rating plate. This provides the best performance
and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
Never unplug your dryer by pulling on the
power cord. Always grip plug firmly and pull straight out from the outlet. The power cord
can be damaged, resulting in a risk of fire and electrical shock.
Repair or replace immediately all power
cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end. The power cord can melt,
creating electrical shock and/or fire hazard.
When installing or moving the dryer, be
careful not to pinch, crush, or damage the power cord. This will prevent injury and
prevent damage to the dryer from fire and electrical shock.
SAVE THESE INSTRUCTIONS
7
PART S A N D F E AT U R E S
8
SPECIAL FEATURES
EASY-TO-USE CONTROL PANEL
1
Rotate the Cycle Selector Knob to select the desired dry cycle. Add cycle options or adjust settings with the touch of a button.
EASY-ACCESS REVERSIBLE DOOR
2
Wide-opening door provides easy access for loading and unloading. Door swing can be reversed to adjust for installation location.
ULTRA-CAPACITY STAINLESS STEEL DRUM
3
WITH DRUM LIGHT
The ultra-large stainless steel drum offers superior durability. The drum is equipped with a yellow light that illuminates when the dryer door is open and turns off when the door is closed.
4
3
1
2
4
HELPFUL STEAM FUNCTIONS
LG’s new steam technology allows you to inject fabrics with a swirling jet of hot steam to refresh clothes, reduce static, and make ironing easier. Simply select the STEAM FRESH™ cycle, or you can add a steam option to selected cycles.
KEY PARTS AND COMPONENTS
In addition to the special features and components outlined in the Special Features section, there are several other important components that are referenced in this manual.
1
FRONT-MOUNT LINT FILTER
Front-mounted lint filter allows for easy access and cleaning after every load.
2
LEVELING FEET
Four leveling feet (two in the front, and two in the back) adjust to improve dryer stability on uneven floors.
PART S A N D F E AT U R E S
1
DRYING RACK
3
Use the drying rack with the RACK DRY cycle option. The drying rack allows items, such as sweaters, delicates, and gym shoes, to be placed in a flat position for drying.
4
PLC MODEM
The PLC modem is used when installing the optional Remote Laundry Monitor (purchased separately).
Included Accessories
Power Cord Location (Gas Models)
Gas Connection Location (Gas Models)
2
Terminal Block Access Panel (Electric Models)
4
Exhaust Duct Outlet
Drying Rack
3
Rear of Dryer
9
I N S TA L L AT I O N I N S T RU C T I O N S
30"
(76.1 cm)
50"
(127 cm)
20"
(50.8 cm)
4"
(10 cm)
18"
(45.72 cm)
4"
(10 cm)
27"
(68.6 cm)
1"
(2.54 cm)
1"
(2.54 cm)
24 in.
2
(155 cm2)
3"
(7.6 cm)
3"
(7.6 cm)
48 in.
2
(310 cm2)
10
IMPORTANT: Read all installation instructions completely before installing and operating your dryer!
It is important that you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust requirements are provided on the following pages.
CHOOSE THE PROPER LOCATION
• Store and install the dryer where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions.
• Choose a location with a solid, level floor.
• If the dryer is being installed in a garage, place the dryer at least 18 in. (46 cm) above the floor.
CLEARANCES
• Properly ground dryer to conform with all governing codes and ordinances.
• To reduce the risk of electric shock, do not install the dryer in damp or wet locations.
• If you are installing your dryer in a manufactured or mobile home, please refer to the section
Special Requirements for Manufactured or Mobile Homes.
Closet Door Vent Requirements
• Most installations require a minimum 5½ in. (14 cm) clearance behind the dryer for the exhaust ducting.
• Allow minimum clearances of at least 1 in. (2.5 cm) on the sides and back to minimize vibration and noise.
• Allowing additional clearance for installation and servicing is recommended.
• Be sure to allow for wall, door, or floor moldings that may increase the required clearances.
• Allow at least 24 in. (61 cm) in front of the dryer to open the door.
Additional Instructions for closet installations:
• The closet door must allow for sufficient airflow. Refer to the diagram above for minimum vent opening requirements. A louvered door is also acceptable.
• Make sure that there is at least 18 in. (46 cm) of clearance above the dryer.
I N S TA L L AT I O N I N S T RU C T I O N S
30"
(76.1 cm)
4"
(10 cm)
27"
(68.6 cm)1"(2.54 cm)
1"
(2.54 cm)
771/2"
(190.5 cm)
INSTALLATION WITH OPTIONAL PEDESTAL BASE OR STACKING KIT
IMPORTANT: If you are installing your dryer using an optional pedestal base or stacking kit, please refer to Optional Accessories in this manual or to the instructions for your pedestal
or stacking kit before proceeding with the installation.
Required Dimensions for Installation
With Pedestal
Required Dimensions for Installation
With Stacking Kit
OPTIONAL ACCESSORIES
For these and other LG products, contact your local LG dealer, or visit our Web site at us.lge.com.
Pedestal (sold separately)
Stacking Kit (sold separately)
11
I N S TA L L AT I O N I N S T RU C T I O N S
12
LEVELING THE DRYER
To ensure that the dryer provides optimal drying performance, it must be level. To minimize vibration, noise, and unwanted movement, the floor must be a perfectly level, solid surface.
NOTE: Adjust the leveling feet only as far as necessary to level the dryer. Extending the leveling feet more than necessary can cause the dryer to vibrate.
Level
Leveling Feet
1
Position the dryer in the final location. Place a level across the top of the dryer.
• All four leveling feet must rest solidly on the floor. Gently push on the top corners of the dryer to make sure that the dryer does not rock from corner to corner.
If you are installing the dryer on the optional pedestal, you must use the leveling feet on the pedestal to level the dryer. The dryer leveling feet should be fully retracted.
2
Use an adjustable wrench to turn the leveling feet. Turn clockwise to raise the dryer or counterclockwise to lower it. Raise or lower the leveling feet until dryer is level from side to side and front to back.
Make sure that all 4 leveling feet are in firm contact with the floor.
REVERSING THE DOOR SWING
The swing of the dryer door can be reversed to fit your installation location.
Door Latch
Hinge
Latch Screws
Open the dryer door. Using a Phillips
1 2
screwdriver, remove the 2 screws that secure the door hinge to the dryer door opening. Remove the 4 screws from the latch side of the dryer door opening, and remove the door latch.
Screws
Turn the door around so the hinge is reversed, and reattach the door using the 2 screws previously removed. Reinstall the door latch and the 4 screws.
Test the door swing to make sure the door moves freely and latches securely.
Latch Screws
Hinge Screws
I N S TA L L AT I O N I N S T RU C T I O N S
11/2"
(3.8 cm)
CHANGING THE DRYER VENT LOCATION
Your new dryer is shipped to vent to the rear. It can also be configured to vent to the bottom or side (right-side venting is not available on gas models).
An adapter kit, part number 383EEL9001B, may be purchased from your LG retailer. This kit contains the necessary duct components to change the dryer vent location.
OPTION 1: Side Venting
Adapter duct
Bracket
Knockout
Rear Exhaust Duct
1
Remove the rear exhaust duct retaining
1
screw. Pull out the exhaust duct.
OPTION 2: Bottom Venting
Adapter Duct
Bracket
Retaining Screw
2
Press the tabs on the knockout and carefully remove the knockout for the desired vent opening (right-side venting is not available on gas models). Press the adapter duct onto the blower housing and secure to the base of the dryer as shown.
Cover Plate
Elbow
3
Preassemble a 4-in. (10 cm) elbow to the next 4-in. (10 cm) duct section, and secure all joints with duct tape. Be sure that the male end of the elbow faces AWAY from the dryer. Insert the elbow/duct assembly through the side opening and press it onto the adapter duct. Secure in place with duct tape.
Be sure that the male end of the duct protrudes 1½ in. (3.8 cm) to connect the remaining ductwork. Attach cover plate to the back of the dryer with included screw.
2
Press the adapter duct onto the blower housing and secure to the base of the dryer as shown.
Cover Plate
Elbow
3
Insert the 4-in. (10 cm) elbow through the rear opening and press it onto the adapter duct. Be sure that the male end of the elbow faces down through hole in the bottom of the dryer. Secure in place with duct tape.
Attach the cover plate to the back of the dryer with included screw.
13
I N S TA L L AT I O N I N S T RU C T I O N S
14
VENTING THE DRYER
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
Do not crush or collapse ductwork. Failure
to follow these instructions can result in fire or death.
Do not allow ductwork to rest on or contact sharp objects. Failure to follow these instructions can result in fire or death.
If connecting to existing ductwork, make
sure it is suitable and clean before installing the dryer. Failure to follow these instructions
can result in fire or death.
Venting must conform to local building codes. Failure to follow these instructions can result in fire or death.
Gas dryers MUST exhaust to the outdoors. Failure to follow these instructions can result in fire or death.
Use only 4-in. (10 cm) rigid or flexible metal
ductwork inside the dryer cabinet and for venting outside. Failure to follow these
instructions can result in fire or death.
To reduce the risk of fire, combustion, or
accumulation of combustible gases, DO NOT exhaust dryer air into an enclosed and unventilated area, such as an attic, wall, ceiling, crawl space, chimney, gas vent, or concealed space of a building. Failure to
follow these instructions can result in fire or death.
To reduce the risk of fire, DO NOT exhaust the dryer with plastic or thin foil ducting. Failure to follow these instructions can result in fire or death.
The exhaust duct must be 4 in. (10 cm) in
diameter with no obstructions. The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer. Failure to follow
these instructions can result in fire or death.
Rigid or semirigid metal ducting is
recommended for use between the dryer and the wall. In special installations when it is impossible to make a connection with the above recommendations, a UL-listed flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will affect drying time. Failure to follow these instructions can
result in fire or death.
DO NOT use sheet metal screws or other
fasteners which extend into the duct that could catch lint and reduce the efficiency of the exhaust system. Secure all joints with duct tape. Failure to follow these
instructions can result in fire or death.
To maximize operating results, please
observe the duct length limitations noted in the chart on page 15. Failure to follow these
instructions can result in fire or death.
Ductwork is not provided with the dryer.
You should obtain the necessary ductwork locally. The end cap should have hinged dampers to prevent backdraft when the dryer is not in use. Failure to follow these
instructions can result in fire or death.
I N S TA L L AT I O N I N S T RU C T I O N S
4"
(10.2 cm)
21/2"
(6.35 cm)
4"
(10.2 cm)
VENTING THE DRYER (cont.)
Ductwork
Number of Max. Length of 4-In. Dia. Max. Length of 4-In. Dia. Wall Cap Type 90° Elbows Rigid Metal Duct Flexible Metal Duct
0 65 ft. (19.8 m) 45 ft. (13.7 m)
Recommended
1 55 ft. (16.8 m) 35 ft. (10.7 m) 2 47 ft. (13.7 m) 30 ft. (9.1 m) 3 36 ft. (11.0 m) 25 ft. (7.6 m) 4 28 ft. (8.5 m) 20 ft. (6.1 m) 0 55 ft. (16.8 m) 35 ft. (10.7 m)
Use Only for Short
2 41 ft. (12.5 m) 21 ft. (6.4 m) 3 30 ft. (9.1 m) 17 ft. (5.2 m) 4 22 ft. (6.7 m) 15 ft. (4.5 m)
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended to use more than four 90° elbows.
Run Installations
1 47 ft. (13.7 m) 27 ft. (8.1 m)
Routing and Connecting Ductwork
Follow the guidelines below to maximize drying performance and reduce lint buildup and condensation in the ductwork.
NOTE: Ductwork and fittings are NOT included and must be purchased separately.
• Use 4-in. (10 cm) diameter rigid or semirigid metal ductwork.
• The exhaust duct run should be as short as possible.
• Use as few elbow joints as possible.
• The male end of each section of exhaust duct must point away from the dryer.
• Use duct tape on all duct joints.
• Insulate ductwork that runs through unheated areas in order to reduce condensation and lint buildup on duct surfaces.
IMPORTANT: Failure to exhaust the dryer correctly will void the dryer’s warranty.
Correct Venting
Incorrect Venting
15
I N S TA L L AT I O N I N S T RU C T I O N S
16
CONNECTING GAS DRYERS
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
Gas supply requirements:
As shipped from the factory, this dryer is configured for use with natural gas. It can be converted for use with LP (Liquefied Propane) gas. Gas pressure must not exceed 13 in. water column.
A qualified service or gas company technician
must connect the dryer to the gas service.
Failure to do so can result in fire, explosion, or death.
Isolate the dryer from the gas supply system
by closing its individual manual shutoff valve during any pressure testing of the gas supply.
Failure to do so can result in fire, explosion, or death.
Supply line requirements:
Your laundry room must have a rigid gas supply line to your dryer. In the United States, an individual manual shutoff valve MUST be installed within at least 6 ft. (1.8 m) of the dryer, in accordance with the National Fuel Gas Code ANSI Z223.1. A 1/8-in. NPT pipe plug must be installed. Failure to do so can result in fire,
explosion, or death.
If using a rigid pipe, the rigid pipe should be
1/2-in. IPS. If acceptable under local codes and ordinances and when acceptable to your gas supplier, 3/8-in. approved tubing may be used where lengths are less than 20 ft. (6.1 m). Larger tubing should be used for lengths in excess of 20 ft. (6.1 m). Failure to do so can
result in fire, explosion, or death.
Connect the dryer to the type of gas shown on
the nameplate. Failure to do so can result in fire, explosion, or death.
To prevent contamination of the gas valve,
purge the gas supply of air and sediment before connecting the gas supply to the dryer. Before tightening the connection between the gas supply and the dryer, purge remaining air until the odor of gas is detected. Failure to do
so can result in fire, explosion, or death.
DO NOT use an open flame to inspect for gas
leaks. Use a noncorrosive leak-detection fluid.
Failure to do so can result in fire, explosion, or death.
Use only a new AGA- or CSA-certified gas
supply line with flexible stainless steel connectors. Failure to do so can result in fire,
explosion, or death.
Securely tighten all gas connections. Failure to
do so can result in fire, explosion, or death.
Use Teflon® tape or a pipe-joint compound that
is insoluble in Liquefied Petroleum (LP) gas on all pipe threads. Failure to do so can result in fire,
explosion, or death.
DO NOT attempt any disassembly of the dryer;
any disassembly requires the attention and tools of an authorized and qualified service person or company. Failure to do so can result
in fire, explosion, or death.
Electrical Requirements for Gas Models Only
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
Do not, under any circumstances, cut or
remove the third (ground) prong from the power cord. Failure to follow this warning can result in
fire, explosion, or death.
For personal safety, this dryer must be properly grounded. Failure to follow this warning can result
in fire, explosion, or death.
The power cord of this dryer is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance. Failure to follow this
warning can result in fire, explosion, or death.
This dryer must be plugged into a 120-VAC, 60-Hz. grounded outlet protected by a 15-ampere fuse or circuit breaker. It is also recommended that a separate circuit serving only this dryer be provided. Failure to follow this
warning can result in fire, explosion, or death.
Where a standard 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet. Failure
to follow this warning can result in fire, explosion, or death.
I N S TA L L AT I O N I N S T RU C T I O N S
CONNECTING GAS DRYERS (cont.)
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
Installation and service must be performed
by a qualified installer, service agency, or the gas supplier. Failure to do so can result in fire,
explosion, or death.
Use only a new stainless steel flexible
connector and a new AGA-certified connector. Failure to do so can result in fire,
explosion, or death.
A gas shutoff valve must be installed within 6 ft. (1.8 m) of the dryer. Failure to do so can result in fire, explosion, or death.
The dryer is configured for Natural Gas when
shipped from the factory. Make sure that the dryer is equipped with the correct burner nozzle for the type of gas being used (Natural Gas or Liquefied Petroleum). Failure to do so
can result in fire, explosion, or death.
If necessary, the correct nozzle (for the LP
nozzle kit order part number 4948EL4002B) should be installed by a qualified technician and the change should be noted on the dryer.
Failure to do so can result in fire, explosion, or death.
All connections must be in accordance with local codes and regulations. Failure to do so can result in fire, explosion, or death.
Gas dryers MUST exhaust to the outdoors. Failure to do so can result in fire, explosion, or death.
Connecting the Gas Supply
Make sure that the gas supply to the laundry
1
room is turned OFF. Confirm that the type of gas available in your laundry room is appropriate for the dryer. The dryer is prepared for Natural Gas with a 3/8-in. NPT gas connection.
Remove the shipping cap from the gas
2
connection at the back of the dryer. Be careful not to damage the threads of the gas connector when removing the shipping cap.
Connect the dryer to your laundry room’s gas
3
supply using a new flexible stainless steel connector with a 3/8-in. NPT fitting.
Securely tighten all connections between the
4
dryer and your laundry room’s gas supply. Turn on your laundry room’s gas supply and check all pipe connections (both internal and external) for gas leaks with a noncorrosive leak-detection fluid.
Electrical Connection
Plug dryer into a
120-VAC, 60-Hz.
grounded 3-prong outlet.
1/8" NPT Pipe
3/8" NPT Gas Connection
AGA/CSA-Certified Stainless Steel Flexible Connector
Plug
Gas Supply Shutoff Valve
High-Altitude Installations
The BTU rating of this dryer is AGA-certified for elevations below 10,000 feet.
If your gas dryer is being installed at an elevation above 10,000 feet, it must be derated by a qualified technician or gas supplier.
17
I N S TA L L AT I O N I N S T RU C T I O N S
18
CONNECTING ELECTRIC DRYERS
wWARNING: To help prevent fire, electric shock, serious injury, or death, the wiring and
grounding must conform to the latest edition of the National Electrical Code, ANSI/NFPA 70 and all applicable local regulations. Please contact a qualified electrician to check your home’s wiring and fuses to ensure that your home has adequate electrical power to operate the dryer.
Electrical Requirements for Electric Models Only
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
This dryer must be connected to a grounded
metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer. Failure to do
so can result in fire, explosion, or death.
The dryer has its own terminal block that
must be connected to a separate 240 VAC, 60-Hertz, single-phase circuit, fused at 30 amperes (the circuit must be fused on both sides of the line). ELECTRICAL SERVICE FOR THE DRYER SHOULD BE OF THE MAXIMUM RATE VOLTAGE LISTED ON THE NAMEPLATE. DO NOT CONNECT DRYER TO 110-, 115-, OR 120-VOLT CIRCUIT. Heating elements are available for field installation in dryers which are to be connected to an electrical service of a different voltage than that listed on the rating plate. Failure to follow
these instructions can result in fire, explosion, or death.
If branch circuit to dryer is 15 ft. (4.5 m)
or less in length, use UL (Underwriters Laboratories) listed No.-10 AWG wire (copper wire only), or as required by local codes. If over 15 ft. (4.50 m), use UL-listed No.-8 AWG wire (copper wire only), or as required by local codes. Allow sufficient slack in wiring so dryer can be moved from its normal location when necessary. Failure
to do so can result in fire, explosion, or death.
The power cord (pigtail) connection between
wall receptacle and dryer terminal block IS NOT supplied with dryer. Type of pigtail and gauge of wire must conform to local codes and with instructions on the following pages. Failure to follow these instructions can
result in fire, explosion, or death.
A 4-wire connection is required for all mobile
and manufactured home installations, as well as all new construction after January 1, 1996. A 4-wire connection must be used where local codes do not permit grounding through the neutral wire. Failure to do so can
result in fire, explosion, or death.
Special Electrical Requirements for Mobile or Manufactured Homes
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
• Any installation in a manufactured or mobile home must comply with the Manufactured Home Construction and Safety Standards Title 24 CFR, Part 32-80 or Standard CAN/ CSA0Z240 MH and local codes and ordinances.
A 4-wire connection is required for all mobile
and manufactured home installations, as well as all new construction after January 1, 1996.
Failure to do so can result in fire, explosion, or death.
I N S TA L L AT I O N I N S T RU C T I O N S
CONNECTING ELECTRIC DRYERS (cont.)
wWARNING:
• Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow these instructions may result in a short or overload.
Grounding through the neutral conductor is prohibited for: (1) new branch-circuit
• installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.
Four-Wire Connection for Electric Dryers: Power Cord
• A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996.
• A UL-listed strain relief is required.
Terminal Block
UL-Listed Strain Relief
UL-Listed 4-Wire Power Cord
1
Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread a UL-listed, 30A, 240V, 4-wire, #10 AWG-minimum copper conductor power cord through the strain relief.
• Use a 30-amp, 240V, UL-listed power cord with #10 AWG-minimum copper conductor and closed loop or forked terminals with upturned ends.
Neutral
Hot
(White)
(Black)
Ground Screw
Power Cord Ground Wire
2
Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cord to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cord ground wire to the green ground screw. TIGHTEN ALL SCREWS SECURELY. Reinstall the terminal block access cover.
Hot (Red)
19
I N S TA L L AT I O N I N S T RU C T I O N S
20
CONNECTING ELECTRIC DRYERS (cont.)
wWARNING:
• Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow these instructions may result in a short or overload.
Grounding through the neutral conductor is prohibited for: (1) new branch-circuit
• installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.
Four-Wire Connection for Electric Dryers: Direct Wire
• A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996.
• A UL-listed strain relief is required.
1" (2.5 cm)
Ground Wire
5"
(12.7 cm)
1
Remove 5 inches (12.7 cm) of the outer covering from the wire. Remove 5 inches of insulation from the ground wire. Cut off approximately 11⁄2 inches (3.8 cm) from the other three wires and strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three shorter wires into a hook shape.
Hot (Black)
Neutral (White)
Hot (Red)
• Use UL-listed 4-wire #10 AWG-minimum copper conductor cable.
• Allow at least 5 ft (1.5 m) length to allow for removal and reinstallation of the dryer.
Terminal Block
UL-Listed Strain Relief
UL-Listed 4-Wire Power Cord
2
Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain relief.
Ground Screw
Ground Wire
3
Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cable to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cable ground wire to the green ground screw. TIGHTEN ALL SCREWS SECURELY. Reinstall the terminal block access cover.
I N S TA L L AT I O N I N S T RU C T I O N S
CONNECTING ELECTRIC DRYERS (cont.)
wWARNING:
• Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow these instructions may result in a short or overload.
Grounding through the neutral conductor is prohibited for: (1) new branch-circuit
• installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.
Three-Wire Connection for Electric Dryers: Power Cord
• A 3-wire connection is NOT permitted on new construction after January 1, 1996.
• A UL-listed strain relief is required.
Terminal Block
UL-Listed Strain Relief
1
Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread a UL-listed, 30A, 240V, 3-wire, #10 AWG-minimum copper conductor power cord through the strain relief.
UL-Listed 3-Wire Power Cord
• Use a 30-amp, 240V, UL-listed power cord with #10 AWG-minimum copper conductor and closed loop or forked terminals with upturned ends.
Neutral
Hot
(White)
(Black)
Ground Screw
Ground Wire
2
Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. TIGHTEN ALL SCREWS SECURELY. Reinstall the terminal block access cover.
Hot (Red)
21
22
I N S TA L L AT I O N I N S T RU C T I O N S
CONNECTING ELECTRIC DRYERS (cont.)
wWARNING:
• Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow these instructions may result in a short or overload.
Grounding through the neutral conductor is prohibited for: (1) new branch-circuit
• installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.
Three-Wire Connection for Electric Dryers: Direct Wire
• A 3-wire connection is NOT permitted on new construction after January 1, 1996.
• A UL-listed strain relief is required.
1" (2.5 cm)
1
Remove 31⁄2 inches (8.9 cm) of the outer covering from the wire. Strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three wires into a hook shape.
Hot (Black)
Neutral (White)
Hot (Red)
• Use UL-listed 3-wire #10 AWG-minimum copper conductor cable.
• Allow at least 5 ft (1.5 m) length to allow for removal and reinstallation of the dryer.
Terminal Block
UL-Listed Strain Relief
UL-Listed 3-Wire Power Cord
2
Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain relief.
Ground Screw
Ground Wire
3
Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. TIGHTEN ALL SCREWS SECURELY. Reinstall the terminal block access cover.
I N S TA L L AT I O N I N S T RU C T I O N S
SPECIAL REQUIREMENTS FOR MANUFACTURED OR MOBILE HOMES
Any installation in a manufactured or mobile home must comply with the Manufactured Home Construction and Safety Standards Title 24 CFR, Part 32-80 or Standard CAN/CSA0Z240 MH and local codes and ordinances. If you are uncertain whether your proposed installation will comply with these standards, please contact a service and installation professional for assistance.
• A gas dryer must be permanently attached to the floor.
• The electrical connection for an electric dryer must be a 4-wire connection. More detailed information concerning the electrical connection is provided in the section Connecting Electric Dryers.
• To reduce the risk of combustion and fire, the dryer must be vented to the outside.
• DO NOT vent the dryer under a manufactured home or mobile home.
• Electric dryers may be vented to the outside using the back, left, right, or bottom panel.
• Gas dryers may be vented to the outside using the back, left, or bottom panel. Gas dryers may not be vented to the outside using the right side panel because of the burner housing.
• The dryer exhaust duct must be affixed securely to the manufactured or mobile home structure, and the exhaust duct must be made of a material that will resist fire and combustion. It is recommended that you use a rigid or flexible metal duct.
• DO NOT connect the dryer exhaust duct to any other duct, vent, chimney, or other exhaust duct.
• Make sure the dryer has adequate access to outside fresh air to ensure proper operation. The opening for outside fresh air must be at least 25 in2 (163 cm2).
• It is important that the clearance of the duct from any combustible construction be at least 2 in. (5 cm), and when venting the dryer to the outdoors, the dryer can be installed with a clearance of 1 in. (2.5 cm) at the sides and back of the dryer.
• Please be aware that venting materials are not supplied with the dryer. You should obtain the venting materials necessary for proper installation.
FINAL INSTALLATION CHECK
Once you have completed the installation of the dryer and it is in its final location, confirm proper operation with the following tests.
Testing Dryer Heating
GAS MODELS
Close the dryer door, press the ON/OFF switch to turn the dryer on, and start the dryer on a heat setting. When the dryer starts, the igniter should ignite the main burner.
NOTE: If all air is not purged from the gas line, the gas igniter may turn off before the main burner ignites. If this happens, the igniter will reattempt gas ignition after approximately two minutes.
ELECTRIC MODELS
Close the dryer door, press the ON/OFF switch to turn the dryer on, and start the dryer on a heat setting. The exhaust air should be warm after the dryer has been operating for 3 minutes.
Checking Airflow
Effective dryer operation requires proper airflow. The adequacy of the airflow can be measured by evaluating the static pressure. Static pressure in the exhaust duct can be measured with a manometer, placed on the exhaust duct approximately 2 ft. (60.9 cm) from the dryer. Static pressure in the exhaust duct should not exceed 0.6 in. (1.5 cm). The dryer should be checked while the dryer is running with no load.
Checking Levelness
Once the dryer is in its final location, recheck the dryer to be sure it is level. Make sure it is level front to back and side to side, and that all 4 leveling feet are firmly on the floor.
23
I N S TA L L AT I O N I N S T RU C T I O N S
Tumble dry
Dry
Normal
Permanent Press
/
wrinkle resistant
Gentle/
delicate
Do not tumble dry
Do not dry (used with
do not wash)
Heat setting
High
Medium
Low
No heat/air
24
Following are instructions for starting and using your new dryer. Please refer to specific sections of this manual for more detailed information. Important Warning: To reduce the risk of fire, electric shock,
or injury to persons, read this entire manual, including the Important Safety Instructions, before operating this dryer.
SORTING LOADS
Fabric Care Labels
Fabric Care Labels
Most articles of clothing feature fabric care labels that include instructions for proper care.
Grouping Similar Items
For best results, sort clothes into loads that can be dried with the same drying cycle.
Different fabrics have different care requirements, and some fabrics will dry more quickly than others.
LOADING THE DRYER
wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this
appliance, follow basic precautions, including the following:
Check all pockets to make sure that they are
empty. Items such as clips, pens, coins, and keys can damage both your dryer and your clothes. Flammable objects such as lighters or matches could ignite, causing a fire.
Failure to do so can result in fire, explosion, or death.
Never dry clothes that have been exposed to
oil, gasoline, or other flammable substances. Washing clothes will not completely remove oil residues. Failure to obey this warning can
result in fire, explosion, or death.
• Combine large and small items in a load.
• Damp clothes will expand as they dry. Do not overload the dryer; clothes require room to tumble dry properly.
• Close zippers, hooks, and drawstrings to prevent these items from snagging or tangling on other clothes.
CHECK THE LINT FILTER BEFORE EVERY LOAD
Always make sure the lint filter is clean before starting a new load; a clogged lint filter will increase drying times.
To clean, pull the lint filter straight up and roll any lint off the filter with your fingers. Do not rinse or wash the filter to remove lint. Push the lint filter firmly back into place. See “Care and Cleaning” for more information.
Always ensure the lint filter is properly installed before running the dryer. Running the dryer with a loose or missing lint filter may damage the dryer and articles in the dryer.
Lint Filter
H OW TO U S E
CONTROL PANEL FEATURES
Following are instructions for starting and using your new dryer. Please refer to specific sections of this manual for more detailed information. Important Warning: To reduce the risk of fire,
electric shock, or injury to persons, read this entire manual, including the Important Safety Instructions, before operating this dryer.
8
1
1
POWER ON/OFF BUTTON
Press to turn the dryer ON. Press again to turn the dryer OFF.
NOTE: Pressing the ON/OFF button during a cycle will cancel that cycle and any load settings will be lost.
2
CYCLE SELECTOR KNOB
Turn this knob to select the desired cycle. Once the desired cycle has been selected, the standard presets will be shown in the display. On MANUAL DRY cycles, these settings can be adjusted using the cycle setting buttons anytime before starting the cycle.
3
START/PAUSE BUTTON
Press this button to START the selected cycle. If the dryer is running, use this button to PAUSE the cycle without losing the current settings.
NOTE: If you do not press the START/PAUSE button to resume a cycle within 4 minutes, the dryer automatically turns off.
4
MORE TIME/LESS TIME BUTTONS
To adjust the drying time, use these buttons with MANUAL DRY, TIME DRY, and STEAM FRESH™ cycles, as well as the REDUCE STATIC and EASY IRON options. Press the MORE TIME button to increase the selected manual cycle time by a minute; press LESS TIME to decrease the cycle time by a minute.
2
4
3
5
CYCLE SETTING BUTTONS
Use these buttons to select the desired cycle settings for the selected cycle. The current settings are shown in the display. Press the button for that option to view and select other settings.
6
TIME AND STATUS DISPLAY
The display shows the settings, estimated time remaining, options, and status messages for your dryer.
7
OPTION BUTTONS
The OPTION buttons allow you to select additional cycle options. Certain buttons also allow you to activate special functions by pressing and holding the button for 3 seconds.
For detailed information about the individual options, please see the following pages.
8
USEFUL STEAM FUNCTIONS
During the STEAM FRESH™ cycle and when selecting Steam options, the swirl nozzle injects fabrics with hot steam to refresh, reduce static, and help make ironing easy.
6
5
4
7
25
H OW TO U S E
CycleType
Jeans, heavyweight items
25
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
32
34
MEDIUM
LOW
ULTRA LOW
HIGH
LOW
Normal
Normal
Normal
Normal
Normal
MID HIGH
Off
Denims, towels, heavy cottons
Work clothes, corduroys, etc.
Workout wear, sheer or lacy garments
For small loads with short drying times
HEAVY DUTY
COTTON/ TOWELS
NORMAL
Permanent press, synthetic items
PERM. PRESS
ULTRA DELICATE
Lingerie, sheets, blouses
DELICATES
SPEED DRY
Fabric Type
Dry
Level
Temperature
Time
in Min.
More Time/
Less Time
Wrinkle
Care
Damp
Dry
Anti-
Bacterial
30
Adjustable
No Heat
Off
For items that require heat-free drying such as plastics or rubber
AIR DRY
40
AdjustableAdjustable
HIGH
Off
For general drying; time, temperature, and options can be set manually
TIME DRY
HIGH
54
55
MID HIGH
20
41
36
Normal
STEAM CYCLE / SENSOR DRY MANUAL DRY
50
Adjustable
ULTRA LOW
LOW
Off
Off
Wool sweaters, silk, lingerie
RACK DRY
STEAM FRESH
Reduce
Static
Easy
Iron
Comforter, Shirts, Trousers
(
except
especially delicate fabrics
)
Off
26
CYCLE GUIDE
The cycle guide below shows the options and recommended fabric types for each cycle.
SENSOR DRY Cycles
SENSOR DRY cycles utilize LG’s unique dual sensor system to detect and compare the moisture level in clothes and in the air and adjust the drying time as needed to ensure superior results. The dryer automatically sets the dryness level and temperature at the recommended setting for each cycle. The estimated time remaining will be shown in the display.
NOTE: To protect your garments, not every dry level, temperature, or option is available with every cycle.
MANUAL DRY Cycles
Use MANUAL DRY cycles to select a specific amount of drying time and a drying temperature. When a MANUAL DRY cycle is selected, the ESTIMATED TIME REMAINING display shows the actual time remaining in your cycle. You can change the actual time in the cycle by pressing MORE TIME or LESS TIME.
H OW TO U S E
THE DISPLAY
The display shows the settings, estimated time remaining, options, and status messages for your dryer.
2
3
1
4
1
ESTIMATED TIME REMAINING
When the START/PAUSE button is pressed, the display will indicate the estimated time remaining for the selected drying cycle.
CYCLE COMPLETION INDICATOR WITH
2
CHECK FILTER REMINDER
This portion of the display shows which stage of the drying cycle is currently underway (CHECK FILTER, DRY, COOLING, or WRINKLE CARE).
5
3
CHILD LOCK INDICATOR
When CHILD LOCK is set, the Child Lock indicator will appear and all buttons are disabled. This prevents children from changing settings while the dryer is operating.
4
CHECK FILTER REMINDER
The display will show CHECK FILTER when the dryer is turned on as a reminder to check the filter. It turns off when the START/PAUSE button is pressed.
5
CUSTOM PROGRAM
If you have a special combination of settings that you use frequently, you can save these settings as a CUSTOM PROGRAM.
27
Loading...
+ 61 hidden pages