LG DLGX3251V Owner's manual [es]

<![if ! IE]>

<![endif]>ESPAÑOL ENGLISH

OWNEr’S MANuAL

DrYer

Please read this owner’s manual thoroughly before operating and keep it handy for reference at all times.

DleX3250* DlGX3251* * = a-Z

 

 

 

 

 

 

 

 

 

www.lg.com

MFL67731045

 

 

 

MFL67731045_en_150106.indd 1

2015.1.6 5:45:30 PM

2 TABLE OF CONTENTS

TABLE OF CONTENTS

3 IMPORTANT SAFETY INSTRUCTIONS

3What to Do if You Smell Gas

4Basic Safety Precautions

5Grounding Instructions

5Safety Instructions for Installation

6Safety Instructions for Steam Functions

7Safety Instructions for Connecting Electricity

8special features

9INTRODUCING YOUR DRYER

9 Parts

9Accessories

10Control Panel Features

11Display

12INSTALLATION INSTRUCTIONS

12Preview Installation Order

13Installation Location Requirements

13Clearances

14Installation with Optional Pedestal Base or Stacking Kit

15Leveling the Dryer

16Reversing the Door

18Installing the Side Vent Kit

19Venting the Dryer

21 Connecting Gas Dryers

23 Connecting Electric Dryers

28Special Requirements for Manufactured or Mobile Homes

28Final Installation Check

29Installation Test (Exhaust check)

31 HOW TO USE

31Operating the Dryer

32Cycle Guide

33Sorting Laundry

33Loading the Dryer

33Check the Lint Filter Before Every Load

34Cycle setting buttons

35Special Functions

36 Custom Program

36 Steam Functions

38Steam Cycle Guide

39MAINTENANCE

39Regular Cleaning

40TROUBLESHOOTING

40 Before Calling for Service

43SPECIFICATIONS

44USING Smart Diagnosis™

45OPTIONAL ACCESSORIES

45 Stacking Kit Installation

MFL67731045_en_150106.indd 2

2015.1.6 5:45:30 PM

IMPORTANT SAFETY INSTRUCTIONS

3

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

Your safety and the safety of others is very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

w

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word DANGER, WARNING, or CAUTION. These words mean:

wDANGER

You will be killed or seriously injured if you don’t immediately follow instructions.

wWarning

You can be killed or seriously injured if you don’t follow instructions.

wcaution

You may be slightly injured or cause damage to the product if you do not follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

Do not install a clothes dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint.These conditions will obstruct clothes dryer airflow and increase the risk of fire.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance or any other appliances.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

Install the clothes dryer according to the manufacturer’s instructions and local codes.

Save these instructions.

WHATTO DO IFYOU SMELL GAS:

1.Do not try to light a match or cigarette, or turn on any gas or electrical appliance.

2.Do not touch any electrical switches. Do not use any phone in your building.

3.Clear the room, building, or area of all occupants.

4.Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions carefully.

5.If you cannot reach your gas supplier, call the fire department.

wWarning:This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

<![if ! IE]>

<![endif]>ENGLISH

MFL67731045_en_150106.indd 3

2015.1.6 5:45:30 PM

4 IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

BASIC SAFETY PRECAUTIONS

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions,

including the following:

Read all instructions before using the dryer.

Before use, the dryer must be properly installed as described in this manual.

Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.

Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, drycleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.

Do not reach into the dryer if the drum or any other part is moving.

Do not repair or replace any part of the dryer or attempt any servicing unless specifically

recommended in this owner’s manual or in published user-repair instructions that you understand and have the skills to carry out.

Do not tamper with controls.

Before the dryer is removed from service or discarded, remove the door to the drying compartment.

Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.

Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.

Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.

Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.

The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.

Do not install or store the dryer where it will be exposed to the weather.

Always check the inside of the dryer for foreign objects.

Clean lint screen before or after each load.

Do not store plastic, paper, or clothing that may burn or melt on top of the dryer during operation.

MFL67731045_en_150106.indd 4

2015.1.6 5:45:30 PM

IMPORTANT SAFETY INSTRUCTIONS

5

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance must be

equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

This appliance must be connected to a grounded metal, permanent wiring system or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

Electric shock can result if the dryer is not properly grounded.

wWarning

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt that the appliance is properly grounded.

SAFETY INSTRUCTIONS FOR INSTALLATION

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions,

including the following:

Properly ground dryer to conform with all governing codes and ordinances. Follow details in the installation instructions. Electric shock can result if the dryer is not properly grounded.

Before use, the dryer must be properly installed as described in this manual. Electric shock can result if the dryer is not properly grounded.

Install and store the dryer where it will not be exposed to temperatures below freezing or exposed to the weather.

All repairs and servicing must be performed by an authorized servicer unless specifically recommended in this owner’s manual. Use only authorized factory parts. Failure to follow this

warning can cause serious injury, fire, electric shock, or death.

To reduce the risk of electric shock, do not install the dryer in humid spaces. Failure to follow this warning can cause serious injury, fire, electric shock, or death.

Connect to a properly rated, protected, and sized power circuit to avoid electrical overload. Improper power circuit can melt, creating electric shock and/or fire hazard.

Remove all packing items and dispose of all shipping materials properly. Failure to do so can result in death, explosion, fire, or burns.

Place dryer at least 18 inches above the floor for a garage installation. Failure to do so can result in death, explosion, fire, or burns.

Keep all packaging from children. Packaging material can be dangerous for children. There is a risk of suffocation.

Do not install near another source of heat such as a stove, cooking oven. Failure to do so can cause deform, smoke and fire.

Do not place candles, smoking materials, or other flammables on top of the product. Dripping wax, smoke, or fire can result.

Remove all protective vinyl film from the product.

Failure to do so can cause product damage, smoke or fire.

<![if ! IE]>

<![endif]>ENGLISH

MFL67731045_en_150106.indd 5

2015.1.6 5:45:30 PM

6 IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

SAFETY INSTRUCTIONS FOR INSTALLATION

wWarning

To reduce the risk of injury to persons, follow all industry recommended safety procedures including the use of long sleeved gloves and safety glasses. Failure to follow all of the safety warnings in this manual could result in property damage, injury to persons, or death.

Exhaust/Ducting:

Gas dryers MUST be exhausted to the outside.

Failure to follow these instructions can result in fire or death.

The dryer exhaust system must be exhausted to the outside of the dwelling. If the dryer is not exhausted outdoors, some fine lint and large amounts of moisture will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard.

Use only rigid metal or flexible metal 4-inch diameter ductwork inside the dryer cabinet or for exhausting to the outside. Use of plastic or other combustible ductwork can cause a fire. Punctured ductwork can cause a fire if it collapses or becomes otherwise restricted in use or during installation.

Ductwork is not provided with the dryer, and you should obtain the necessary ductwork locally.The end cap should have hinged dampers to prevent backdraft when the dryer is not in use. Failure to follow these instructions can result in fire or death.

The exhaust duct must be 4 inches (10.2 cm) in diameter with no obstructions.The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new

dryer. Failure to follow these instructions can result in fire or death.

Rigid or semi-rigid metal ducting is recommended for use between the dryer and the wall. In special installations when it is impossible to make a connection with the above recommendations, a ULlisted flexible metal transition duct may be used between the dryer and wall connection only.The use of this ducting will affect drying time. Failure to follow these instructions can result in fire or death.

DO NOT use sheet metal screws or other fasteners which extend into the duct that could catch lint and reduce the efficiency of the exhaust system. Secure all joints with duct tape. For complete details, follow the Installation Instructions. Failure to follow these instructions can result in fire or death.

SAFETY INSTRUCTIONS FOR STEAM FUNCTIONS

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions,

including the following:

Do not open the dryer door during steam cycles.

Failure to follow these instructions can result in a burn hazard.

Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode. Failure to follow these instructions can result in fire or death.

Do not fill the steam feeder with gasoline, drycleaning solvents, or other flammable or explosive substances. Failure to follow these instructions can result in fire or death.

Do not touch the steam nozzle in the drum during or after the steam cycle. Failure to follow these instructions can result in a burn hazard.

Do not fill the steam feeder with hot water (over 86 ˚F/30 ˚C). Failure to follow these instructions can result in a burn hazard.

MFL67731045_en_150106.indd 6

2015.1.6 5:45:30 PM

IMPORTANT SAFETY INSTRUCTIONS

7

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

SAFETY INSTRUCTIONS FOR CONNECTING ELECTRICITY

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not, under any circumstances, cut or remove the ground prong from the power cord. To prevent injury to persons or damage to the dryer, the electrical power cord must be plugged into a properly grounded outlet.

For personal safety, this dryer must be properly grounded. Failure to do so can result in electric shock or injury.

Refer to the installation instructions in this manual for specific electrical requirements for your model.

Failure to follow these instructions can create an electric shock hazard and/or a fire hazard.

This dryer must be plugged into a properly grounded outlet. Electric shock can result if the dryer is not properly grounded. Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Failure to follow these instructions can create an electric shock hazard and/or a fire hazard.

The dryer should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate. This provides sparkling performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

Never unplug your dryer by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet. The power cord can be damaged, resulting in a risk of fire and electric shock.

Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end. The power cord can melt, creating an electric shock and/or fire hazard.

When installing or moving the dryer, be careful not to pinch, crush, or damage the power cord. This will prevent injury and prevent damage to the dryer from fire and electric shock.

<![if ! IE]>

<![endif]>ENGLISH

SAVETHESE INSTRUCTIONS

MFL67731045_en_150106.indd 7

2015.1.6 5:45:31 PM

8 special features

SPECIAL FEATURES

Easy-to-USE Control Panel

Rotate the cycle selector knob to select the desired dry cycle. Add cycle options or adjust settings with the touch of a button.

EASY-ACCESS REVERSIBLE DOOR

The wide-opening door provides easy access for loading and unloading. The door hinge can be reversed to adjust for installation location.

STEAM FUNCTIONS

LG’s steam technology allows you to inject fabrics with a swirling jet of hot steam to refresh clothes, reduce static, and make ironing easier. Simply select the Steam Fresh™ cycle, or you can add a Steam option to selected cycles.

FLOW SENSE™ DUCT BLOCKAGE SENSING SYSTEM INDICATOR

The FLOW SENSE™ duct blockage sensing system detects and alerts you to restrictions in the installed household ductwork that reduce exhaust airflow through the dryer. If you see the alert: Clean or repair the ducts to remove the restrictions. Keep your ducts clean to help increase efficiency and reduce long drying times caused by blocked ducts.

Smart Diagnosis™

Should you experience any technical difficulty with your dryer, it has the capability of transmitting data via your telephone to the Customer Information Center. The call center agent records the data transmitted from your machine and uses it to analyze the issue, providing a fast and effective diagnosis.

MFL67731045_en_150106.indd 8

2015.1.6 5:45:31 PM

INTRODUCING YOUR DRYER

9

INTRODUCING YOUR DRYER

Parts

 

Reversible

Power Cord

 

Control

door

Location

Terminal

panel

 

(Gas

Block

 

Models)

Access

 

 

 

 

 

Panel

 

 

 

(Electric

 

 

 

Models)

 

Lint filter

Gas

Exhaust

Leveling

Connection

Duct

 

feet

 

Location

Outlet

 

 

(Gas Models)

 

<![if ! IE]>

<![endif]>ENGLISH

Accessories

Included accessories

Optional accessories

Drying rack

Pedestal

Stacking kit

(sold separately)

(sold separately)

 

NOTE

Contact LG Customer Service at if any accessories are missing.

For your safety and for extended product life, use only authorized components.The manufacturer is not responsible for product malfunction or accidents caused by the use of separately purchased unauthorized components or parts.

The images in this owner’s manual may be different from the actual components and accessories, and are subject to change by the manufacturer without prior notice for product improvement purposes.

MFL67731045_en_150106.indd 9

2015.1.6 5:45:33 PM

10 INTRODUCING YOUR DRYER

Control Panel Features

Following are instructions for starting and using your new dryer. Please refer to specific sections of this manual for more detailed information.

wWarning

To reduce the risk of fire, electric shock, or injury to persons, read this entire manual, including the Important Safety Instructions, before operating this dryer.

 

 

Cycle Selector Knob

LED Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

Start/Pause

 

Dry Level

 

Time Dry

Temp. Control

Button

 

Button

 

Button

 

Button

Button

Operation

 

 

 

 

Button

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy

POWER ON/OFF BUTTON

 

 

 

 

 

 

 

 

 

 

 

 

- Press to turn the dryer ON. Press again to turn the dryer OFF.

 

 

 

 

 

 

 

 

 

 

 

 

NOTE : Pressing the ON/OFF button during a cycle will cancel that cycle and

 

 

 

 

 

 

 

 

 

 

 

 

any load settings will be lost.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy

CYCLE SELECTOR KNOB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Turn this knob to select the desired cycle. Once the desired cycle has been

 

 

 

 

 

 

 

 

 

 

 

 

selected, the standard presets will be shown in the display. On MANUAL DRY

 

 

 

 

 

 

 

 

 

 

 

 

cycles, these settings can be adjusted using the cycle setting buttons anytime

 

 

 

 

 

 

 

 

 

 

 

 

before starting the cycle.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy

START/PAUSE BUTTON

 

 

 

 

 

 

 

 

 

 

 

 

- Press this button to START the selected cycle. If the dryer is running, use this

 

 

 

 

 

 

 

 

 

 

 

 

button to PAUSE the cycle without losing the current settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE : If you do not press the START/PAUSE button to resume a cycle within 4

 

 

 

 

 

 

 

 

 

 

 

 

minutes, the dryer turns off automatically.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy

MORETIME/LESSTIME BUTTONS

 

 

 

 

 

 

 

 

 

 

 

 

- To adjust the drying time, use these buttons with MANUAL DRY and TIME DRY.

 

 

 

 

 

 

 

 

 

 

 

 

Press the MORE TIME button to increase the selected manual cycle time by a

 

 

 

 

 

 

 

 

 

 

 

 

minute; press LESS TIME to decrease the cycle time by a minute.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy

CYCLE MODIFIER BUTTONS

 

 

 

 

 

 

 

 

 

 

 

 

- Use these buttons to select the desired cycle settings for the selected cycle.

 

 

 

 

 

 

 

 

 

 

 

 

The current settings are shown in the display. Press the button for that option

 

 

 

 

 

 

 

 

 

 

 

 

to view and select other settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy

OPTION BUTTONS

 

 

 

 

 

 

 

 

 

 

 

 

- The OPTION buttons allow you to select additional cycle options. Not all

 

 

 

 

 

 

 

 

 

 

 

 

settings are available for all cycles. Refer to the CYCLE GUIDE section of the

 

 

 

 

 

 

 

 

 

 

 

 

manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

MFL67731045_en_150106.indd 10

2015.1.6 5:45:42 PM

INTRODUCING YOUR DRYER 11

Display

The display shows the settings, estimated time remaining, options, and status messages for your dryer. When the dryer is turned on, the light in the display will illuminate.

wWarning

To reduce the risk of fire, electric shock, or injury to persons, read this entire manual, including the Important Safety Instructions, before operating this dryer.

<![if ! IE]>

<![endif]>ENGLISH

Display and icons

 

 

Description

 

yy

EstimatedTime Remaining

 

 

- When the START/PAUSE button is pressed, the dryer will display the estimated

 

 

(SENSOR DRY) or set time (TIME DRY) remaining, and begin tumbling.

 

 

NOTE :The cycle time on SENSOR DRY cycles may fluctuate as the dryer

 

 

recalculates drying time for optimal results.

 

 

 

 

 

yy

CYCLE COMPLETION INDICATORWITH CHECK FILTER REMINDER

-This portion of the display shows which stage of the drying cycle is currently underway (CHECK FILTER, DRYING, COOLING, orWRINKLE CARE).

yy Child Lock Indicator

-When CHILD LOCK is set, the CHILD LOCK indicator will appear and all buttons are disabled except the POWER button. This prevents children from changing settings while the dryer is operating.

yy Check FILTER reminder

-The display will show CHECK FILTER when the dryer is turned on as a reminder to check the filter. It turns off when the START/PAUSE button is pressed.

yy CUSTOM PROGRAM

-If you have a special combination of settings that you use frequently, you can save these settings as a CUSTOM PROGRAM.

yy FLOW SENSE™ DUCT BLOCKAGE SENSING SYSTEM INDICATOR

- The FLOW SENSE™ duct blockage sensing system detects and alerts you to blockages in the ductwork that reduce exhaust flow from the dryer. This improves operating efficiency and helps minimize service calls, saving your money.

MFL67731045_en_150106.indd 11

2015.1.6 5:45:48 PM

12 INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Preview Installation Order

Checking and choosing the

Leveling the dryer

Venting the dryer

 

proper location

 

 

 

 

 

120V

240V

Connecting gas dryers Connecting electric dryers

Plugging in the power cord

 

and grounding

Press and hold

 

Installation test

Test run

(Refer to page 29.)

 

MFL67731045_en_150106.indd 12

2015.1.6 5:45:50 PM

INSTALLATION INSTRUCTIONS 13

Installation Location Requirements

wWarning

Read all installation instructions completely before installing and operating your dryer! It is important that you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust requirements are provided on the following pages.

• A location that allows for proper exhaust installation. A

• A sturdy floor to support the total dryer weight of 200

gas dryer must be exhausted to the outdoors.

lbs (90.7 kg). The combined weight of a companion

See Venting the dryer.

appliance should also be considered.

• A grounded electrical outlet located within 2 ft.

• No other fuel-burning appliance can be installed in the

(61 cm) of either side of the dryer. See Connecting

same closet as a dryer.

electric dryers.

 

Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.

NOTE

A level floor with a maximum slope of 1 inch (2.5 cm) under entire dryer. If slope is greater than 1 inch (2.5 cm), install the Extended Dryer Feet Kit. Clothes may not tumble properly, and automatic sensor cycles may not operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer at least 18 inches (46 cm) above the floor. If using a pedestal, you will need 18 inches (46 cm) to the bottom of the dryer.

Clearances

 

14" max.*

 

(35.6 cm)

 

18" min.*

 

(45.7 cm)

1"*

30"

5"**

(2.5 cm) (76.1 cm) (12.7 cm)

 

14" max.*

 

3"*

 

 

 

 

 

 

(7.6 cm)

 

 

 

 

 

(35.6 cm)

48 in.2*

 

 

 

 

 

 

 

18" min.*

(310 cm2)

 

 

 

0"

 

 

 

(45.7 cm)

 

 

 

 

(0 cm)

 

 

 

 

 

 

 

 

 

39"

 

 

 

 

 

 

 

 

 

(99.1 cm)

 

 

 

 

 

24 in.2*

3"

*

 

1"

27"

1"

 

 

 

(155 cm2)

 

 

 

 

 

 

(7.6 cm)

 

(2.5 cm)

(68.6 cm)

(2.5 cm)

1"*

30"

5"**

 

 

1"

27"

1"

 

 

(2.5 cm)

(76.1 cm)

(12.7 cm)

 

 

(2.5 cm)

(68.6 cm)

(2.5 cm)

 

 

Installation Spacing For Recessed Area Or Closet Installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of

1 inches(2.54cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

NOTE

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of vibration from one to the other. Too much vibration, it could cause them to make noise or touch each other causing paint damage and making even more noise.

<![if ! IE]>

<![endif]>ENGLISH

MFL67731045_en_150106.indd 13

2015.1.6 5:45:53 PM

14 INSTALLATION INSTRUCTIONS

Installation with optional pedestal base or stacking kit

Recommended installation spacing for cabinet installation

• For cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.

*Required spacing

7"* (17.8 cm)

7"* (17.8 cm)

**For side or bottom venting,

2 inches (5.1 cm) spacing is allowed.

9"**

(22.9 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5"**

30"

1"**

1"

27"

1"

 

(12.7 cm) (76.1 cm) (2.5 cm)

(2.5 cm)(68.6 cm) (2.5 cm)

Closet ventilation requirements

Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup in the closet. One upper vent opening with a minimum opening of 48 sq. in. (310 cm2) must be installed no lower than 6 feet above the floor. One lower vent opening with a minimum opening of 24 sq. in. (155 cm2) must be installed no more than one foot above the floor. One example shown uses vent grilles in the door.

Recommended installation spacing for recessed or closet installation, with stacked washer and dryer

• The dimensions shown are for the recommended spacing.

*Required spacing

**For side or bottom venting,

2 inches (5.1 cm) spacing is allowed.

771/2"

(196.8 cm)

 

1"* (2.5 cm)

52/4"**

 

 

 

(14 cm)

MFL67731045_en_150106.indd 14

2015.1.6 5:45:57 PM

INSTALLATION INSTRUCTIONS 15

Leveling the dryer

wWarning

To reduce the risk of injury to persons, adhere to all industry recommended safety procedures including the use of long sleeved gloves and safety glasses.

Failure to follow this warning can cause serious injury or death.

The appliances are heavy.Two or more people are required when installing the dryer. Failure to follow this warning can cause serious injury or death.

To ensure that the dryer provides optimal drying performance, it must be level. To minimize vibration, noise, and unwanted movement, the floor must be a perfectly level, solid surface.

NOTE

Adjust the leveling feet only as far as necessary to level the dryer. Extending the leveling feet more than necessary can cause the dryer to vibrate.

1.Position the dryer in the final location. Place a level across the top of the dryer.

2.Use an adjustable wrench to turn the leveling feet. Turn clockwise to raise the dryer or counterclockwise to lower it. Raise or lower the leveling feet until dryer is level from side to side and front to back.

Make sure that all 4 leveling feet are in firm contact with the floor.

<![if ! IE]>

<![endif]>ENGLISH

Level

Leveling Feet

All four leveling feet must rest solidly on the floor.

Gently push on the top corners of the dryer to make sure that the dryer does not rock from corner to corner.

If you are installing the dryer on the optional pedestal, you must use the leveling feet on the pedestal to level the dryer. The dryer leveling feet should be fully retracted.

MFL67731045_en_150106.indd 15

2015.1.6 5:45:58 PM

16 INSTALLATION INSTRUCTIONS

Reversing the Door

wWarning

To avoid damage to the dryer or the door, support the door with a stool or box that fits under the door, or have an assistant support the weight of the door.

Always reverse the door BEFORE stacking the dryer on top of the washer.

Avoid dropping the door to avoid damage to the door or the floor.

THE DRYER DOOR IS VERY LARGE AND HEAVY. Failure to follow the instructions below can result in damage to the dryer, property damage or injury to persons.

1. Open the door to reverse.

4. Remove two screws and disassembly latch.

Latch Screw

CAUTION

Be sure to support the weight of the door before removing the hinge screws.

5.Hold on the hinge while remove 2 screws of hinge (to prevent door dropping).

Hinge Screw

Open Door

2. Check screws to remove (Left 4, Right 2).

6. Remove door from cabinet cover.

3. Remove four dummy screws by driver.

Remove

Door

 

Hinge

Dummy

Screw

MFL67731045_en_150106.indd 16

2015.1.6 5:46:5 PM

LG DLGX3251V Owner's manual

INSTALLATION INSTRUCTIONS 17

Reversing the Door (cont.)

wWarning

To avoid damage to the dryer or the door, support the door with a stool or box that fits under the door, or have an assistant support the weight of the door.

Always reverse the door BEFORE stacking the dryer on top of the washer.

Avoid dropping the door to avoid damage to the door or the floor.

THE DRYER DOOR IS VERY LARGE AND HEAVY. Failure to follow the instructions below can result in damage to the dryer, property damage or injury to persons.

1. Move door to left side and insert a hinge to hinge hole.

Hinge hole

CAUTION

Be sure to support the weight of the door before removing the hinge screws.

2.Hold on hinge while screw down a hinge (to prevent door dropping).

Hinge Screw

4. Screw down four dummy screws right side.

Decorative

Hinge

Screw

5. Check that the door closes and latches properly.

Swing Door

3. Insert latch to right side and install screws.

Latch

Screw

<![if ! IE]>

<![endif]>ENGLISH

MFL67731045_en_150106.indd 17

2015.1.6 5:46:14 PM

18 INSTALLATION INSTRUCTIONS

Installing the Side Vent Kit

wWarning

Use a heavy metal vent.

Do not use plastic or thin foil duct.

Clean old ducts before installing this dryer.

To reduce the risk of injury to persons, adhere to all industry recommended safety procedures including the use of long sleeved gloves and safety glasses.

Failure to follow all of the safety warnings in this manual could result in property damage, injury to persons, or death.

Your new dryer is shipped to vent to the rear.

It can also be configured to vent to the bottom or side (right-side venting is not available on gas models).

An adapter kit, part number 383EEL9001B, may be purchased from your LG retailer. This kit contains the necessary duct components to change the dryer vent location.

1.Remove the rear exhaust duct retaining screw. Pull out the exhaust duct.

Retaining

Screw

Rear

Exhaust Duct

Option 1: Side Venting

2.Press the tabs on the knockout and carefully remove the knockout for the desired vent opening (rightside venting is not available on gas models). Press the adapter duct onto the blower housing and secure to the base of the dryer as shown.

Adapter

Duct

Bracket

Knockout

3.Preassemble a 4 inches (10.2 cm) elbow to the next 4-inches (10.2 cm) duct section, and secure all joints with duct tape. Be sure that the male end of the elbow faces AWAY from the dryer. Insert the elbow/duct assembly through the side opening and press it onto the adapter duct. Secure in place with duct tape.

Be sure that the male end of the duct protrudes 1½ inches (3.8 cm) to connect the remaining ductwork.

Attach cover plate to the back of the dryer with included screw.

Cover

Plate

Elbow

11/2

 

(3.8 cm)

Option 2: Bottom Venting

2.Press the adapter duct onto the blower housing and secure to the base of the dryer as shown.

Adapter

Duct

Bracket

3.Insert the 4 inches (10.2 cm) elbow through the rear opening and press it onto the adapter duct. Be sure that the male end of the elbow faces down through hole in the bottom of the dryer. Secure in place with duct tape.

Attach the cover plate to the back of the dryer with included screw.

Cover

Plate

Elbow

MFL67731045_en_150106.indd 18

2015.1.6 5:46:17 PM

INSTALLATION INSTRUCTIONS 19

Venting the Dryer

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not crush or collapse ductwork. Failure to follow these instructions can result in fire or death.

Do not allow ductwork to rest on or contact sharp objects. Failure to follow these instructions can result in fire or death.

If connecting to existing ductwork, make sure it is suitable and clean before installing the dryer.

Failure to follow these instructions can result in fire or death.

Venting must conform to local building codes.

Failure to follow these instructions can result in fire or death.

Gas dryers MUST exhaust to the outdoors.

Failure to follow these instructions can result in fire or death.

Use only 4-inch (10.2 cm) rigid or flexible metal ductwork inside the dryer cabinet and for venting outside. Failure to follow these instructions can result in fire or death.

To reduce the risk of fire, combustion, or accumulation of combustible gases, DO NOT exhaust dryer air into an enclosed and unventilated area, such as an attic, wall, ceiling, crawl space, chimney, gas vent, or concealed space of a building. Failure to follow these instructions can result in fire or death.

To reduce the risk of fire, DO NOT exhaust the dryer with plastic or thin foil ducting.

Failure to follow these instructions can result in fire or death.

The exhaust duct must be 4 inches (10.2 cm) in diameter with no obstructions. The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new

dryer. Failure to follow these instructions can result in fire or death.

Rigid or semirigid metal ducting is recommended for use between the dryer and the wall. In special installations when it is impossible to make a connection with the above recommendations, a UL-listed flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will affect drying time. Failure to follow these instructions can result in fire or death.

DO NOT use sheet metal screws or other fasteners which extend into the duct that could catch lint and reduce the efficiency of the exhaust system. Secure all joints with duct tape. Failure to follow these instructions can result in fire or death.

To maximize operating results, please observe the duct length limitations noted in the chart next page. Failure to follow these instructions can result in fire or death.

Ductwork is not provided with the dryer. You should obtain the necessary ductwork locally. The end cap should have hinged dampers to prevent backdraft when the dryer is not in use. Failure to follow these instructions can result in fire or death.

The total length of flexible metal duct shall not exceed 8 ft. (2.4 m)

In Canada, that only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer shall be used. In the United States, that only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer and that comply with the Outline for Clothes Dryer Transition Duct, Subject 2158A, shall be used.

<![if ! IE]>

<![endif]>ENGLISH

MFL67731045_en_150106.indd 19

2015.1.6 5:46:17 PM

20

INSTALLATION INSTRUCTIONS

 

Venting the Dryer (cont.)

 

Ductwork

 

 

 

 

 

Number Of

Maximum Length Of

Correct Venting

Wall Cap Type

90° Elbows

4-inch Diameter

 

 

 

 

Rigid Metal Duct

 

Recommended

0

65 ft. (19.8 m)

 

 

 

1

55 ft. (16.8 m)

 

 

4”

2

47 ft. (14.3 m)

 

 

(10.2 cm)

 

 

 

3

36 ft. (11.0 m)

 

 

4”

4

28 ft. (8.5 m)

 

 

(10.2 cm)

 

Use only for

0

55 ft. (16.8 m)

 

 

short run

1

47 ft. (14.3 m )

 

installations

 

 

 

2

41 ft. (12.5 m)

 

 

 

3

30 ft. (9.1 m)

 

22/4

 

 

 

(6.35 cm)

4

22 ft. (6.7 m)

 

 

 

Incorrect Venting

 

 

 

 

NOTE

Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended to use more than four 90° elbows.

Routing and Connecting Ductwork

NOTE

Follow the guidelines below to maximize drying performance and reduce lint buildup and condensation in the ductwork.

Ductwork and fittings are NOT included and must be purchased separately.

Use 4-inch (10.2 cm) diameter rigid or semirigid metal ductwork.

The exhaust duct run should be as short as possible.

Use as few elbow joints as possible.

The male end of each section of exhaust duct must point away from the dryer.

Use duct tape on all duct joints.

Insulate ductwork that runs through unheated areas in order to reduce condensation and lint buildup on duct surfaces.

Incorrect or inadequate exhaust systems are not covered by the dryer warranty. Failures or poor performance caused by such exhaust systems will not be covered by the dryer warranty.

MFL67731045_en_150106.indd 20

2015.1.6 5:46:19 PM

INSTALLATION INSTRUCTIONS 21

Connecting Gas Dryers

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Gas supply requirements:

As shipped from the factory, this dryer is configured for use with natural gas. It can be converted for use with LP (Liquefied Propane) gas. Gas pressure must not exceed 13 inches of water column.

A qualified service or gas company technician must connect the dryer to the gas service.

Failure to do so can result in fire, explosion, or death.

Isolate the dryer from the gas supply system by closing its individual manual shutoff valve during any pressure testing of the gas supply. Failure to do so can result in fire, explosion, or death.

Supply line requirements:

Your laundry room must have a rigid gas supply line to your dryer. In the United States, an individual manual shutoff valve MUST be installed within at least 6 ft. (1.8 m) of the dryer, in accordance with the National Fuel Gas Code

ANSI Z223.1 or Canadian gas installation code CSA B149.1. A 1⁄ - inch NPT pipe plug must be installed.

Failure to do so can result in fire, explosion, death.

If using a rigid pipe, the rigid pipe should be ½ - inch IPS. If acceptable under local codes and ordinances and when acceptable to your gas

supplier, 3⁄ - inch approved tubing may be used where lengths are less than 20 ft. (6.1 m). Larger tubing should be used for lengths in excess of 20 ft. (6.1 m). Failure to do so can result in fire, explosion, or death.

Electrical requirements for gas models only

wWarning

Connect the dryer to the type of gas shown on the nameplate. Failure to do so can result in fire, explosion, or death.

To prevent contamination of the gas valve, purge the gas supply of air and sediment before connecting the gas supply to the dryer. Before tightening the connection between the gas supply and the dryer, purge remaining air until the odor of gas is detected. Failure to do so can result in fire, explosion, or death.

DO NOT use an open flame to inspect for gas leaks. Use a noncorrosive leak-detection fluid. Failure to do so can result in fire, explosion, or death.

Use only a new AGAor CSA-certified gas supply line with flexible stainless steel connectors. Failure to do so can result in fire, explosion, or death.

Securely tighten all gas connections. Failure to do so can result in fire, explosion, or death.

DO NOT attempt any disassembly of the dryer; any disassembly requires the attention and tools of an authorized and qualified service person or company. Failure to do so can result in fire, explosion, or death.

Use a pipe-joint compound that is insoluble in Liquefied Petroleum (LP) gas on all pipe threads.

Failure to do so can result in fire, explosion, or death.

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Failure to follow this warning can result in fire, explosion, or death.

For personal safety, this dryer must be properly grounded. Failure to follow this warning can result in fire, explosion, or death.

The power cord of this dryer is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance. Failure to follow this warning can result in fire, explosion, or death.

This dryer must be plugged into a 60 Hz, 120 VAC, grounded outlet protected by a 15-ampere fuse or circuit breaker. Failure to follow this warning can result in fire, explosion, or death.

Where a standard 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet. Failure to follow this warning can result in fire, explosion, or death.

<![if ! IE]>

<![endif]>ENGLISH

MFL67731045_en_150106.indd 21

2015.1.6 5:46:19 PM

22 INSTALLATION INSTRUCTIONS

Connecting Gas Dryers (cont.)

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Installation and service must be performed by a qualified installer, service agency, or the gas

supplier. Failure to do so can result in fire, explosion, or death.

Use only a new stainless steel flexible connector and a new AGA-certified connector. Failure to do so can result in fire, explosion, or death.

A gas shutoff valve must be installed within 6 ft. (1.8 m) of the dryer. Failure to do so can result in fire, explosion, or death.

The dryer is configured for Natural Gas when shipped from the factory. Make sure that the dryer is equipped with the correct burner orifice for the type of gas being used (Natural Gas or Liquefied Petroleum). Failure to do so can result in fire, explosion, or death.

If necessary, the correct orifice (For the LP orifice kit, order part number 383EEL3002D) should be installed by a qualified technician and the change should be noted on the dryer. Failure to do so can result in fire, explosion, or death.

All connections must be in accordance with local codes and regulations. Failure to do so can result in fire, explosion, or death.

Gas dryers MUST exhaust to the outdoors. Failure to do so can result in fire, explosion, or death.

Connecting the gas supply

1.Make sure that the gas supply to the laundry room is turned OFF. Confirm that the type of gas available in

your laundry room is appropriate for the dryer. The dryer is prepared for Natural Gas with a 3⁄ - inch NPT gas connection.

2.Remove the shipping cap from the gas connection at the back of the dryer. Be careful not to damage the threads of the gas connector when removing the shipping cap.

3.Connect the dryer to your laundry room’s gas supply using a new flexible stainless steel connector with a 3⁄ - inch NPT fitting.

4.Securely tighten all connections between the dryer and your laundry room’s gas supply. Turn on your laundry room’s gas supply and check all pipe

connections (both internal and external) for gas leaks with a noncorrosive leak-detection fluid.

Electrical connection

3/8” NPT Gas

Connection

AGA/CSA-Certified Stainless Steel Flexible Connector

Plug dryer into a 120 VAC, 60 Hz grounded 3-prong outlet.

1/8” NPT Pipe

Plug

Gas Supply

Shutoff Valve

High-altitude installations

The BTU rating of this dryer is AGA-certified for elevations below 10,000 feet.

If your gas dryer is being installed at an elevation above

10,000 feet, it must be derated by a qualified technician or gas supplier.

MFL67731045_en_150106.indd 22

2015.1.6 5:46:20 PM

INSTALLATION INSTRUCTIONS 23

Connecting Electric Dryers

wWarning

To help prevent fire, electric shock, serious injury, or death, the wiring and grounding must conform to the latest edition of the National Electrical Code,

ANSI/NFPA 70 and all applicable local regulations.

Please contact a qualified electrician to check your home’s wiring and fuses to ensure that your home has adequate electrical power to operate the dryer.

Electrical requirements for electric models only

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

This dryer must be connected to a grounded metal, permanent wiring system, or an equipmentgrounding conductor must be run with the circuit conductors and connected to the equipmentgrounding terminal or lead on the dryer. Failure to do so can result in fire, explosion, or death.

The dryer has its own terminal block that must be connected to a separate 240 VAC, 60-Hertz, single-phase circuit, fused at 30 amperes (the circuit must be fused on both sides of the line).

ELECTRICAL SERVICE FOR THE DRYER SHOULD BE OF THE MAXIMUM RATE VOLTAGE LISTED ON THE NAMEPLATE. DO NOT CONNECT DRYER TO 110-, 115-, OR 120-VOLT CIRCUIT. Failure to follow these instructions can result in fire, explosion, or death.

If branch circuit to dryer is 15 ft. (4.5 m) or less in length, use UL (Underwriters Laboratories) listed No.-10 AWG wire (copper wire only), or as required by local codes. If over 15 ft. (4.5 m), use UL-listed No.-8 AWG wire (copper wire only), or as required by local codes. Allow sufficient slack in wiring

so dryer can be moved from its normal location when necessary. Failure to do so can result in fire, explosion, or death.

The power cord (pigtail) connection between wall receptacle and dryer terminal block IS NOT supplied with dryer. Type of pigtail and gauge of wire must conform to local codes and with instructions on the following pages. Failure to follow these instructions can result in fire, explosion, or death.

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996. A 4-wire connection must be used where local codes do not permit grounding through the neutral wire. Failure to do so can result in fire, explosion, or death.

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not modify the plug and internal wire provided with the dryer.

The dryer should be connected to 4-hole outlet.

If it does not fit the outlet, a proper outlet will need to be installed by a qualified electrician.

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Any installation in a manufactured or mobile home must comply with the Manufactured Home Construction and Safety Standards Title 24 CFR, Part 3280 or Standard CAN/ CSA Z240 MH and local codes and ordinances.

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996. Failure to do so can result in fire, explosion, or death.

<![if ! IE]>

<![endif]>ENGLISH

MFL67731045_en_150106.indd 23

2015.1.6 5:46:20 PM

24 INSTALLATION INSTRUCTIONS

Connecting Electric Dryers (cont.) USA only

wWarning

Connect the power cord to the terminal block.

Connec teach power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short, overload, fire or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations,

(2) mobile homes, (3) recreational vehicles, and

(4) areas where local codes prohibit grounding through the neutral conductor.

Four-wire connection for electric dryers: Power cord

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread a UL-listed,

30 A, 240 V, 4-wire, #10 AWG-minimum copper conductor power cord through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed

4-Wire Power

Cord

Use a 30 A, 240 V, UL-listed power cord with #10 AWG-minimum copper conductor and closed loop or forked terminals with upturned ends.

2.Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cord to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cord ground wire to the green ground screw. Tighten alL screws securely. Reinstall the terminal block access cover.

Hot

Neutral

(Black)

(White)

Ground

Hot

(Red)

Screw

 

 

White Wire

 

moved from

Power Cord

Ground Screw

 

Ground Wire

 

MFL67731045_en_150106.indd 24

2015.1.6 5:46:21 PM

INSTALLATION INSTRUCTIONS 25

Connecting Electric Dryers (cont.)

USA only

wWarning

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire.

Failure to follow these instructions may result in a short, overload, fire or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations,

(2) mobile homes, (3) recreational vehicles, and

(4) areas where local codes prohibit grounding through the neutral conductor.

Use UL-listed 4-wire #10 AWG-minimum copper conductor cable.

Allow at least 5 ft. (1.5 m) length to allow for removal and reinstallation of the dryer.

3.Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cable to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cable ground wire to the green ground screw. Tighten aLl screws securely. Reinstall the terminal block access cover.

Four-wire connection for electric dryers: Direct wire

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove 5 inches (12.7 cm) of the outer covering from the wire. Remove 5 inches of insulation from the ground wire. Cut off approximately 11⁄ inches (3.8 cm) from the other three wires and strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three shorter wires into a hook shape.

1" (2.5 cm)

Hot

Neutral

(Black)

(White)

Ground

Hot

(Red)

Screw

 

 

White Wire

 

moved from

Power Cord

Ground Screw

 

Ground Wire

 

Ground Wire

5" (12.7 cm)

2.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed 4-Wire

Power Cord

<![if ! IE]>

<![endif]>ENGLISH

MFL67731045_en_150106.indd 25

2015.1.6 5:46:22 PM

26 INSTALLATION INSTRUCTIONS

Connecting Electric Dryers (cont.) USA only

wWarning

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short, overload, fire or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations,

(2)mobile homes, (3) recreational vehicles, and

(4)areas where local codes prohibit grounding through the neutral conductor.

Three-wire connection for electric dryers: Power cord

A 3-wire connection is NOT permitted on new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread a ULlisted, 30 A, 240 V, 3-wire, #10 AWG-minimum copper conductor power cord through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed

3-Wire Power

Cord

Use a 30 A, 240 V, UL-listed power cord with #10 AWG-minimum copper conductor and closed loop or forked terminals with upturned ends.

2.Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. Tighten aLl screws securely. Reinstall the terminal block access cover.

 

Hot

Neutral

 

(White)

 

(Black)

 

 

Ground

 

Hot

Screw

 

(Red)

White Wire from Dryer harness

External Ground Wire (If required by local codes)

MFL67731045_en_150106.indd 26

2015.1.6 5:46:23 PM

INSTALLATION INSTRUCTIONS 27

Connecting Electric Dryers (cont.)

USA only

wWarning

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short, overload, fire or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations,

(2) mobile homes, (3) recreational vehicles, and

(4) areas where local codes prohibit grounding through the neutral conductor.

Three-wire connection for electric dryers: Direct wire

A 3-wire connection is NOT permitted on new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove 31⁄ inches (8.9 cm) of the outer covering from the wire. Strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three wires into a hook shape.

1" (2.5 cm)

2.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

Use UL-listed 3-wire #10 AWG-minimum copper conductor cable.

Allow at least 5 ft. (1.5 m) length to allow for removal and reinstallation of the dryer.

3.Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. Tighten all screws securely. Reinstall the terminal block access cover.

 

Hot

Neutral

 

(White)

 

(Black)

 

 

Ground

 

Hot

Screw

 

(Red)

White Wire from Dryer harness

External Ground Wire (If required by local codes)

UL-Listed 3-Wire

Power Cord

<![if ! IE]>

<![endif]>ENGLISH

MFL67731045_en_150106.indd 27

2015.1.6 5:46:24 PM

28 INSTALLATION INSTRUCTIONS

Special Requirements for Manufactured or Mobile Homes

Any installation in a manufactured or mobile home must comply with the Manufactured Home Construction and

Safety StandardsTitle 24 CFR, Part 3280 or Standard CAN/CSA Z240 MH and local codes and ordinances. If you are uncertain whether your proposed installation will comply with these standards, please contact a service and installation professional for assistance.

A gas dryer must be permanently attached to the floor.

The electrical connection for an electric dryer must be a 4-wire connection. More detailed information concerning the electrical connection is provided in the section Connecting Electric Dryers.

To reduce the risk of combustion and fire, the dryer must be vented to the outside.

DO NOT vent the dryer under a manufactured home or mobile home.

Electric dryers may be vented to the outside using the back, left, right, or bottom panel.

Gas dryers may be vented to the outside using the back, left, or bottom panel. Gas dryers may not be vented to the outside using the right side panel because of the burner housing.

The dryer exhaust duct must be affixed securely to the manufactured or mobile home structure, and the exhaust duct must be made of a material that will resist fire and combustion.

It is recommended that you use a rigid or flexible metal duct.

DO NOT connect the dryer exhaust duct to any other duct, vent, chimney, or other exhaust duct.

Make sure the dryer has adequate access to outside fresh air to ensure proper operation. The opening for outside fresh air must be at least 25 in2 (163 cm2).

It is important that the clearance of the duct from any combustible construction be at least 2 inches (5 cm), and when venting the dryer to the outdoors, the dryer can be installed with a clearance of 1 inch (2.5 cm) at the sides and back of the dryer.

Please be aware that venting materials are not supplied with the dryer. You should obtain the venting materials necessary for proper installation.

Final Installation Check

Once you have completed the installation of the dryer and it is in its final location, confirm proper operation with the following tests and Installation Test (Duct Check) on the following page.

Testing dryer heating

GAS MODELS

Close the dryer door, press the On/Off button to turn the dryer on, and start the dryer on a heat setting.

When the dryer starts, the igniter should ignite the main burner.

NOTE

If all air is not purged from the gas line, the gas igniter may turn off before the main burner ignites. If this happens, the igniter will reattempt gas ignition after approximately two minutes.

ELECTRIC MODELS

Close the dryer door, press the On/Off button to turn the dryer on, and start the dryer on a heat setting. The exhaust air should be warm after the dryer has been operating for 3 minutes.

Checking airflow

Effective dryer operation requires proper airflow. The adequacy of the airflow can be measured by evaluating the static pressure. Static pressure in the exhaust duct can be measured with a manometer,

placed on the exhaust duct approximately 2 ft. (60.9 cm) from the dryer.

Static pressure in the exhaust duct should not exceed 0.6 inches (1.5 cm). The dryer should be checked while the dryer is running with no load.

Checking levelness

Once the dryer is in its final location, recheck the dryer to be sure it is level. Make sure it is level front to back and side to side, and that all 4 leveling feet are firmly on the floor.

MFL67731045_en_150106.indd 28

2015.1.6 5:46:24 PM

INSTALLATION INSTRUCTIONS 29

Installation Test (Exhaust check)

Once you have completed the installation of the dryer, use this test to make sure the condition of the exhaust system is adequate for proper operation of the dryer.

This test should be performed to alert you to any serious problems in the exhaust system of your home.

Your dryer features ™, an innovative sensing system that automatically detects blockages and restrictions in dryer ductwork. Keeping ductwork clean of lint buildup and free of restrictions allows clothes to dry faster and reduces energy use.

NOTE

The dryer should be cool before starting this test. If the dryer was warmed up during installation, run the AIR DRY cycle for a few minutes to reduce the interior temperature.

To activate the installation test:

1.Remove the literature, and then close the door.

Do not load anything in the drum for this test, as in may affect the accuracy of the results.

2.Press and hold the Temp. Control and SIGNAL ON/ OFF buttons and then press the Power button.

This button sequence activates the installation test.

The code will display if the activation is successful.

4.Check the display for results.

During the three minute test cycle, monitor the Flow Sense™ display on the control panel. If no bars are displayed, when the cycle ends, the exhaust system is adequate. If the exhaust system is severely restricted, the display will show four bars. Other problems may also be shown with error codes. Refer to the next page for error code details and solutions.

 

 

 

 

No Bars: Ok

Four Bars:

 

 

 

Restricted

Four bars indicates that the exhaust system is severely restricted. Have the system checked immediately, as performance will be poor.

5.End of cycle.

At the end of the test cycle, will display. The test cycle will end and the dryer will shut off automatically after a short delay.

3.Press Start/Pause button.

The dryer will start the test, which will last about two minutes. The heat will be turned on and the temperatures in the drum will be measured.

<![if ! IE]>

<![endif]>ENGLISH

MFL67731045_en_150106.indd 29

2015.1.6 5:46:27 PM

30 INSTALLATION INSTRUCTIONS

Installation Test (Exhaust check) (cont.)

• Check the error code before you call for service

Error Code

Possible Causes

Solutions

 

 

 

tE1or tE2

• Temperature sensor failure

•Turn off the dryer and call for

 

service.

 

 

 

HS

• Humidity sensor failure.

•Turn off the dryer and call for

 

service.

 

 

 

 

 

 

• Electric dryer power cord is not

• Check the power supply or the

 

connected correctly, or house power

connection of power cord to the

 

supply is incorrect.

terminal block. Refer to the

 

 

Connectingelectricdryerssection of this manual

PSor PFor nP

• House fuse is blown, circuit breaker has

for complete instructions.

 

tripped, or power outage has occurred.

• Reset circuit breaker or replace fuse. Do not increase

 

 

the fuse capacity.

 

 

If the problem is a circuit overload, have it corrected

 

 

by a qualified electrician.

 

 

 

Check the duct condition

If the test displays four bars, check the exhaust system for restrictions and damage. Repair or replace the exhaust system as needed.

NOTE

When the dryer is first installed, this test should be performed to alert you to any existing problems with the exhaust duct in your home. However, since the test performed during normal operation provides more accurate information on the condition of the exhaust duct than does the installation test, the number of bars displayed during the two tests may not be the same.

Do not interrupt the test cycle, as this could result in the wrong results.

Even if no bars are displayed during the test cycle, some restrictions may still be present in the exhaust system. Refer to the Venting the Dryer section of this manual for complete exhaust system and venting requirements.

Your dryer features Flow Sense™, an innovative sensing system that automatically detects blockages and restrictions in dryer ductwork. Keeping ductwork clean of lint buildup and free of restrictions allows clothes to dry faster and reduces energy use.

Restricted or blocked airflow

Avoid long runs or runs with multiple elbows or bends.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Excess or crushed

Too many elbows or

 

transition duct

exhaust too long

Check for blockages and lint buildup.

Lint buildup or blockage

Make sure the ductwork is not crushed or restricted.

Crushed or damaged exhaust

MFL67731045_en_150106.indd 30

2015.1.6 5:46:29 PM