How to assemble the folding sleeve
THROUGH - THE - WALL AIR CONDITIONER
SLEEVE INSTALLATION INSTRUCTIONS
SLEEVE HARDWARE
• TTW Sleeve with Expanded Grille: AXSVB1
• TTW Sleeve with Louvered Grille : AXSVB2
INSTALL THE UNIT
ITEM
➀
➁
➂
➃
➄
➅
DESCRIPTION
SLEEVE LOWER
SLEEVE UPPER
COVER PANEL
REAR GRILLE
WASHER SCREW
SCREW
Q’TY
1
1
2
1
12
4
➀
➁
➃
➂
3828A20209B
WASHER
SCREW
EXPANDED
REAR GRILLE
LOUVERED
REAR GRILLE (OPTION)
Minimum
"
2
1
SLEEVE
LINTEL
(PURCHASED LOCALLY)
(MORTAR)
INSTALLATION OF SLEEVE
INTO PRE-CAST CONCRETE
OR MASONRY WALL
INSIDE OUTSIDE
•Remove the old air conditioner from the existing
wall sleeve and remove the existing wall sleeve.
•Prepare and install the new wall sleeve into the wall
opening.
•The wall sleeve must be fastened in the wall
securely before installing the new air conditioner.
•Keep the cover panels for later use to protect the
unit from rainy or windy weather.
•Receptacle should be installed within 20" of left
side or 45" of right side of wall opening.
• To avoid distortion to plastic air conditioner front,
install sleeve 4" minimum distance from heating
source. (e.g. Baseboard heating, radiator, etc.)
• After sleeve has been installed, caulk where
necessary entire perimeter around exterior wall
opening and sleeve. Use a good grade of caulking
compound to seal all cracks against air and water
infiltration.
• Do not remove front or back cover until all masonry
is set and window frame is in place. this will prevent
buckling of the during sebseqent construction
operatins. the rear gille and washer screws should
be kept well until the air conditioneris installed.
25-7/8"(656mm)
16-23/32"(425mm)
15-17/32"
(394mm)
4" Minimum
SLEEVE DIMENSION
SLEEVE INSTALLATION
ELECTRICAL WALL
RECEPTACLE
16-25/32"
MASONRY OPENING
OR
FRAME OPENING
26-
1
/8" 45"20"
WALL
OPENING
WALL OPENING