LG AVUQ36GM1A0 INSTALLATION MANUAL

P/NO : MFL67448522
INSTALLATION MANUAL
AIR CONDITIONER
www.lg.com
• Please read this installation manual completely before installing the product.
• Please retain this installation manual for future reference after reading it thoroughly.
Single
ENGLISH ESPAÑOL
PORTUGUÊS
2
TIPS FOR SAVING ENERGY
ENGLISH
• Do not cool excessively indoors. This may be harmful to your health and may consume more elec­tricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air condition­er is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them labeled on the side of each unit.
Dealer’s name :
Date of purchase :
Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:
TIPS FOR SAVING ENERGY
IMPORTANT SAFETY INSTRUCTIONS
3
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product
WARNING
It can result in serious injury or death when the directions are ignored
CAUTION
It can result in minor injury or product damage when the directions are ignored
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Installation work must be performed in accordance with the National Electric Code by quali­fied and authorized personnel only.
• The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment mal­function, property damage, personal injury and/or death.
Installation
• Always perform grounding. Otherwise, it may cause electrical shock.
• Don’t use a power cord, a plug or a loose socket which is damaged. Otherwise, it may cause a fire or electrical shock.
• For installation of the product, always contact the service center or a professional installation agency. Otherwise, it may cause a fire, electrical shock, explosion or injury.
• Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit. If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.
• Always install an air leakage breaker and a dedicated switching board. No installation may cause a fire and electrical shock.
• Do not keep or use flammable gases or combustibles near the air conditioner. Otherwise, it may cause a fire or the failure of product.
• Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time. It may cause injury or an accident.
• Do not disassemble or repair the product randomly. It will cause a fire or electrical shock.
• Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress air or Oxygen and do not use Flammable gases. Otherwise, it may cause fire or explosion. There is the risk of death, injury, fire or explosion.
• Do not install the product at a place that there is concern of falling down. Otherwise, it may result in personal injury.
• Use caution when unpacking and installing. Sharp edges may cause injury.
• Do not turn on the breaker or power under condition that front panel, cabinet, top cover, control box cover are removed or opened. Otherwise, it may cause fire, electric shock, explosion or death.
!
!
!
4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
Operation
• Do not share the outlet with other appliances. It will cause an electric shock or a fire due to heat generation.
• Do not use the damaged power cord. Otherwise, it may cause a fire or electrical shock.
• Do not modify or extend the power cord randomly. Otherwise, it may cause a fire or electrical shock.
• Take care so that the power cord may not be pulled during operation. Otherwise, it may cause a fire or electrical shock.
• Unplug the unit if strange sounds, smell, or smoke comes from it. Otherwise, it may cause electrical shock or a fire.
• Keep the flames away. Otherwise, it may cause a fire.
• Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands. Otherwise, it may cause a fire or electrical shock.
• Do not use the power cord near the heating tools. Otherwise, it may cause a fire and electrical shock.
• Do not open the suction inlet of the indoor/outdoor unit during operation. Otherwise, it may electrical shock and failure.
• Do not allow water to run into electrical parts. Otherwise, it may cause the failure of machine or electrical shock.
• Hold the plug by the head when taking it out. It may cause electric shock and damage.
• Never touch the metal parts of the unit when removing the filter. They are sharp and may cause injury.
• Do not step on the indoor/outdoor unit and do not put anything on it. It may cause an injury through dropping of the unit or falling down.
• Do not place a heavy object on the power cord. Otherwise, it may cause a fire or electrical shock.
• When the product is submerged into water, always contact the service center. Otherwise, it may cause a fire or electrical shock.
• Take care so that children may not step on the outdoor unit. Otherwise, children may be seriously injured due to falling down.
CAUTION
Installation
• Install the drain hose to ensure that drain can be securely done. Otherwise, it may cause water leak­age.
• Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors. Otherwise, it may cause dispute with the neighbors.
• Always inspect gas leakage after the installation and repair of product. Otherwise, it may cause the failure of product.
• Keep level parallel in installing the product. Otherwise, it may cause vibration or water leakage.
Operation
• Avoid excessive cooling and perform ventilation sometimes. Otherwise, it may do harm to your health.
• Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent. The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
• Do not use an appliance for special purposes such as preserving animals vegetables, precision machine, or art articles. Otherwise, it may damage your properties.
• Do not place obstacles around the flow inlet or outlet. Otherwise, it may cause the failure of appli­ance or an accident.
!
TABLE OF CONTENTS
5
ENGLISH
2 TIPS FOR SAVING ENER-
GY
3 IMPORTANT SAFETY
INSTRUCTIONS
6 INSTALLATION OF OUT-
DOOR UNIT
8 WIRING CONNECTION
8 Electrical wiring
9 Connecting cables between indoor unit
and outdoor unit
11 Connecting the cable to outdoor unit
12 CONNECTING PIPES
12 Preparation of piping
13 Connecting the pipes to the outdoor unit
14 Forming the piping
15 Plumbing materials and storage meth-
ods
16 Nitrogen substitution method
17 LEAKAGE TEST AND
EVACUATION
17 Preparation
17 Leakage test
18 Evacuation
19 TEST RUNNING
21 FUNCTION
21 Forced cooling operation
22 SELF-DIAGNOSIS FUNC-
TION
22 Error indicator (outdoor)
24 INSTALLATION GUIDE AT
THE SEASIDE
TABLE OF CONTENTS
6
INSTALLATION OF OUTDOOR UNIT
ENGLISH
- If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.
- Ensure that the spaces indicated by arrows around front, back and side of the unit.
- Do not place animals and plants in the path of the warm air.
- Take the air conditioner weight into account and select a place where noise and vibration are minimum.
- Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
More than 300 mm
Fence or
obstacles
More thanMore than 300 mm300 mm
More than 300 mm
Sunroof
More than 700 mm
More than 600 mm
Unit : mm
Installation Places
INSTALLATION OF OUTDOOR UNIT
INSTALLATION OF OUTDOOR UNIT
7
ENGLISH
MODEL CAPACITY
Pipe Size Length A (m) Elevation B (m)
Additional
Refrigerant
(g/m)
Gas Liquid Standard Max. Standard Max.
AVUQ36GM1A0 36 kBtu/h Ø 15,88 (5/8) Ø 9,52 (3/8) 7,5 50 0 30 20
AVUQ48GM2A0 46 kBtu/h Ø 15,88 (5/8) Ø 9,52 (3/8) 7,5 50 0 30 20
AVUQ60GM2A0 58 kBtu/h Ø 19,05 (3/4) Ø 9,52 (3/8) 7,5 50 0 30 20
Piping length and the elevation
Ceiling Suspended Air conditioner
• Capacity is based on standard length and maximum allowance length is on the basis of
reliability.
• Improper refrigerant charge may result in abnormal cycle.
CAUTION
!
If installed tube is shorter than 15 m, additional charging is not necessary. Additional Refrigerant = (A -15) x Additional refrigerant (g)
Indoor unit
B
Outdoor unit
A
Outdoor unit
Indoor unit
A
B
8
WIRING CONNECTION
ENGLISH
Electrical wiring
Perform the electrical wiring work according to the electrical wiring connection.
- All wiring must comply with local require­ments.
- Select a power source that is capable of sup­plying the current required by the air condi­tioner.
- Use a recognized ELCB(Electric Leakage Circuit Breaker) between the power source and the unit. A disconnection device to ade­quately disconnect all supply lines must be fitted.
- Model of circuit breaker recommended by authorized personnel only
Model Phase(Ø) ELCB
AVUQ36GM1A0 1 30 A
AVUQ48GM2A0 1 40 A
AVUQ60GM2A0 1 40 A
WIRING CONNECTION
Main power source
Indoor
ELCB
Switch box
Outdoor
WIRING CONNECTION
9
ENGLISH
Connecting cables between indoor unit and outdoor unit
The power cord connected to the outdoor unit should be complied with IEC 60245 or HD 22.4 S4 (This equipment shall be provided with a cord set complying with the national regulation.
The connecting cable connected to the outdoor unit should be complied with IEC 60245 or HD 22.4 S4 (This equipment shall be provided with a cord set complying with the national regulation.)
If the supply cord is damaged, it must be replaced by a special cord or assembly availible from the manufacturer of its service agent.
When the connection line between the indoor unit and out­dooor unit is over 40 m, connect the telecommunication line and power line separately.
CAUTION
!
GN/YL
20 mm
35±5 mm
10±3 mm
NORMAL CROSS-SECTIONAL AREA 0.75 mm
2
20 mm
GN
/YL
35±5 mm
10±3 mm
Model Phase(Ø) Area(mm2)
AVUQ36GM1A0
14
AVUQ48GM2A0
16
AVUQ60GM2A0
16
Outdoor
unit
3 2
1
Indoor
unit
3 2
1
10
WIRING CONNECTION
ENGLISH
Use round pressure terminals for connections to the power terminal block.
When none are available, follow the instructions below.
- Do not connect wiring of different thicknesses to the power terminal block. (Slack in the power wiring may cause abnormal heat.)
- When connecting wiring which is the same thickness, do as shown in the figure below.
- For wiring, use the designated power wire and connect firmly, then secure to prevent outside pressure being exerted on the terminal block.
- Use an appropriate screwdriver for tightening the terinal screws. A screwdriver with a small head will strip the head and make proper tighterning impossible.
- Over-tightening the terminal screws may break them.
Round pressure terminal
Power wire
Precautions when laying power wiring
WIRING CONNECTION
11
ENGLISH
Connecting the cable to outdoor unit
Remove the side panel for wiring connection. Use the cord clamp to fix the cord. Earthing work
- Connect the cable of diameter more to the earthing terminal provided in the control box and do earthing.
• The circuit diagram is not subject to change without notice.
• Be sure to connect wires according to the wiring diagram.
• Connect the wires firmly, so that not to be pulled out easily.
• Connect the wires according to color codes by referring the wiring diagram.
• The Power cord connected to the unit should be selected according to the following speci­fications.
CAUTION
!
Connecting cable terminal Power cord terminal
Cord clamp
* Make sure the rubber bushes are
properly used in knock-out holes after connecting main power.
12
CONNECTING PIPES
ENGLISH
Preparation of piping
Main cause of gas leakage is defect in flaring work. Carry out correct flaring work in the following procedure.
Cut the pipes and the cable.
- Use the accessory piping kit or the pipes pur­chased locally.
- Measure the distance between the indoor and the outdoor unit.
- Cut the pipes a little longer than measured distance.
- Cut the cable 1.5 m longer than the pipe length.
Burrs removal
- Completely remove all burrs from the cut cross section of pipe/tube.
- Put the end of the copper tube/pipe to down­ward direction as you remove burrs in order to avoid to let burrs drop in the tubing.
Putting nut on
- Remove flare nuts attached to indoor and outdoor units, than put them on pipe/tube having completed burr removal. (Not possible to put them on after flaring work)
Flaring work
- Carry out flaring work using dedicated flaring tool for R-410A as shown below.
Firmly hold copper tube in a bar(or die) as indicated dimension in the table above.
Check
- Compare the flared work with figure below.
- If flare is noted to be defective, cut off the flared section and do flaring work again.
Copper
tube
90°
Slanted Uneven Rough
Pipe
Reamer
Point down
Flare nut
Copper tube
Bar
Copper pipe
Clamp handle
Red arrow mark
Cone
Yo ke
Handle
Bar
"A"
Inclined
Inside is shining without scratches
Smooth all round
Even length
all round
Surface
damaged
Cracked Uneven
thickness
= Improper flaring =
Outside diameter
A
mm inch mm Ø 6,35 1/4 1,1 - 1,3 Ø 9,52 3/8 1,5 - 1,7 Ø 12,7 1/2 1,6 - 1,8
Ø 15,88 5/8 1,6 - 1,8 Ø 19,05 3/4 1,9 - 2,1
CONNECTING PIPES
CONNECTING PIPES
13
ENGLISH
Connecting the pipes to the outdoor unit
Align the center of the piping and sufficiently tighten the flare nut by hand.
Finally, tighten the flare nut with torque wrench until the wrench clicks.
- When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench.
Preventing foreign objects from entering
- Plug the pipe through-holes with putty or insulation material(procured locally)to stop up all gaps.
h When tighten the pipe, hold the haxago-
nal body.
Outside diameter
Torque
mm inch N·m Ø 6,35 1/4 16 ± 2 Ø 9,52 3/8 38 ± 4 Ø 12,7 1/2 55 ± 6
Ø 15,88 5/8 75 ± 7 Ø 19,05 3/4 110 ± 10
Insects or small animals entering the outdoor unit may cause a short circuit in the electrical box.
CAUTION
!
Torque wrench
Contin
-uous
Drain hose
Connecting wire Gas side piping
Liquid side piping
14
CONNECTING PIPES
ENGLISH
Forming the piping
Form the piping by wrapping the connecting portion of the indoor unit with insulation mate­rial and secure it with two kinds of vinyl tape.
- If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately.
In cases where the outdoor unit is installed below the indoor unit perform the following.
1 Tape the piping, drain hose and connecting
cable from down to up.
2 Secure the tapped piping along the exterior
wall using saddle or equivalent.
Plastic band
Seal a small opening around the pipings with gum type sealer.
In cases where the outdoor unit is installed above the indoor unit perform the following.
1 Tape the piping and connecting cable from
down to up.
2 Secure the taped piping along the exterior
wall. Form a trap to prevent water entering the room.
3 Fix the piping onto the wall by saddle or
equivalent.
Trap
TrapTrapTrap
Seal a small opening Seal a small opening around the pipings around the pipings with gum type sealer.with gum type sealer.
Seal a small opening around the pipings with gum type sealant.
Seal a small
Seal a small opening around
opening around
the pipings with
the pipings with
gum type sealant.
gum type sealer.
Plastic
Plastic
band
band
Taping
Drain hose
Pipings
Connecting cable
Power supply cord
• Trap is required to prevent water from entering into electrical parts.
CONNECTING PIPES
15
ENGLISH
Plumbing materials and storage methods
Pipe must be able to obtain the specified thickness and should be used with low impurities. Also when handling storage, pipe must be careful to prevent a fracture, deformity and wound. Should not be mixed with contaminations such as dust, moisture.
Refrigerant piping on three principles
Drying Cleanliness Airtight
Should be no moisture inside No dust inside.
There is no refrigerant leak-
age
Items
Moisture
Dust
Leakage
Cause failure
- Significant hydrolysis of re­frigerant oil
- Degradation of refrigerant oil
- Poor insulation of the com­pressor
- Do not cold and warm
- Clogging of EEV, Capillary
- Degradation of refrigerant oil
- Poor insulation of the com­pressor
- Do not cold and warm
- Clogging of EEV, capillary
- Gas shortages
- Degradation of refrigerant oil
- Poor insulation of the com­pressor
- Do not cold and warm
Counter­measure
- No moisture in the pipe
- Until the connection is completed, the plumbing pipe entrance should be strictly controlled.
- Stop plumbing at rainy day.
- Pipe entrance should be taken side or bottom.
- When removal burr after cutting pipe, pipe entrance should be taken down.
- Pipe entrance should be fitted cap when pass through the walls.
- No dust in the pipe.
- Until the connection is completed, the plumbing pipe entrance should be strictly controlled.
- Pipe entrance should be taken side or bottom.
- When removal burr after cutting pipe, pipe entrance should be taken down.
- Pipe entrance should be fitted cap when pass through the walls.
- Airtightness test should be.
- Brazing operations to com­ply with standards.
- Flare to comply with stan­dards.
- Flange connections to comply with standards.
16
CONNECTING PIPES
ENGLISH
Nitrogen substitution method
Welding, as when heating without nitrogen substitution a large amount of the oxide film is formed on the internal piping.
The oxide film is a caused by clogging EEV, capillary, oil hole of accumulator and suction hole of oil pump in compressor.
It prevents normal operation of the compressor. In order to avoid this problem, Welding should be done after replacing air by nitrogen gas. When welding plumbing pipe, the work is required.
1 Always use the nitrogen.(not use oxygen, carbon dioxide, and a Chevron gas):
Please use the following nitrogen pressure 0,02 MPa Oxygen – promotes oxidative degradation of refrigerant oil. Because it is flammable, it is strictly prohibited to use Carbon dioxide – degrade the drying characteristics of gas
Chevron gas – toxic gas occurs when exposed to direct flame. 2 Always use a pressure reducing valve. 3 Please do not use commercially available antioxidant.
The residual material seems to be the oxide scale is observed.
In fact, due to the organic acids generated by oxidation of the alcohol contained in the anti-
oxidants, ants nest corrosion occurs. (causes of organic acid alcohol + copper + water +
temperature)
CAUTION
!
Regulator
Welding Point
Oxide scale
Note) should not block the outlet side. When the internal pressure in pipe is abo ve the atmospheric pressure, pinhole is o ccurred and it can cause leakage.
Nitrogen gas Pressure 0,02 Mpa less
Taping
(Should not
contain air)
Auxiliary valve
Nitrogen
LEAKAGE TEST AND EVACUATION
17
ENGLISH
Preparation
Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Check that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage.
Leakage test
Connect the manifold valve(with pressure gauges) and dry nitrogen gas cylinder to this service port with charge hoses.
CAUTION
Be sure to use a manifold valve for leakage test. If it is not available, use a stop valve for this purpose. The "Hi" knob of the manifold valve must always be kept close.
- Pressurize the system to no more than 3,0 MPa with dry nitrogen gas and close the cylinder valve when the gauge read­ing reached 3,0 MPa. Next test for leaks with liquid soap.
!
CAUTION
To avoid nitrogen entering the refrigerant system in a liquid state, the top of the cylinder must be higher than its bottom when you pressurize the system. Usually, the cylinder is used in a vertical standing position.
!
- Do a leakage test of all joints of the tubing(both Indoor unit and outdoor unit) and both gas and liquid side service valves. Bubbles indicate a leak. Be sure to wipe off the soap with a clean cloth.
- After the system is found to be free of leaks, relieve the nitrogen pressure by loosening the charge hose connector at the nitrogen cylinder. When the system pressure is reduced to normal, disconnect the hose from the cylinder.
Air and moisture remaining in the refrigerant system have undesirable effects as indicated below.
- Pressure in the system rises.
- Operating current rises.
- Cooling(or heating) efficiency drops.
- Moisture in the refrigerant circuit may freeze and block capillary tubing.
- Water may lead to corrosion of parts in the refrigeration system.
Therefore, the indoor/outdoor unit and con­necting tube must be checked for leak tight, and vacuumed to remove incondensible gas and moisture in the system.
LEAKAGE TEST AND EVACUATION
Indoor unit
Outdoor unit
Manifold valve
Lo Hi
Charge hose
Pressure gauge
Nitrogen gas cylinder(in vertical standing position)
18
LEAKAGE TEST AND EVACUATION
ENGLISH
- When the desired vacuum is reached, close the "Lo and Hi" knob of the manifold valve and stop the vacuum pump.
Required time for evacuation when 30 gal/h
vacuum pump is used
If tubing length is
less than10 m (33 ft)
If tubing length is
longer than 10 m (33 ft)
30 min. or more 60 min. or more
0,67 kPa or less
- With a service valve wrench, turn the valve stem of liquid side valve counter-clockwise to fully open the valve.
- Turn the valve stem of gas side valve counter­clockwise to fully open the valve.
- Loosen the charge hose connected to the gas side service port slightly to release the pressure, then remove the hose.
- Replace the flare nut and its bonnet on the gas side service port and fasten the flare nut secure­ly with an adjustable wrench. This process is very important to prevent leakage from the sys­tem.
- Replace the valve caps at both gas and liquid side service valves and fasten them tightly.
This completes air purging with a vacuum pump. The air conditioner is now ready to test run.
Finishing the job
Evacuation
- Connect the charge hose end described in the preceding steps to the vacuum pump to evacuate the tubing and indoor unit. Confirm the "Lo and Hi" knob of the manifold valve is open. Then, run the vacuum pump. The operation time for evacuation varies with tubing length and capacity of the pump. The following table shows the time required for evacuation.
Indoor unit
Outdoor unit
Manifold valve
Lo Hi
Open
Vacuum pump
Open
Pressure gauge
TEST RUNNING
19
ENGLISH
- The initial power supply must provide at least 90 % of the rated voltage. Otherwise, the air conditioner should not be operated.
- The test run is started by pressing the room temperature checking button and down timer but­ton for 3 seconds at the same time.
- To cancel the test run, press any button.
Check the following items when installation is complete
- After completing work, be sure to measure and record trial run properties, and store measured data, etc.
- Measuring items are room temperature, outside temperature, suction temperature, blow out temperature, wind velocity, wind volume, voltage, current, presence of abnormal vibration and noise, operating pressure, piping temperature, compressive pressure.
- As to the structure and appearance, check following items.
- Connect the power supply cord to the independent power supply. Circuit breaker is required.
- Operate the unit for 15 minutes or more.
Precautions In Test Running
Connection of power supply
Evaluation of the performance
CAUTION
For test run, carry out the cooling operation firstly even during heating season. If heating operation is carried out firstly, it leads to the trouble of compressor. Then attention must be paid.
Carry out the test run more than 5 minutes without fail. (Test run will be cancelled 18 minutes later automatically)
!
Is the circulation of air adequate?Is the draining smooth?Is the heat insulation completed
(refrigerant and drain piping)?
Is there any leakage of refrigerant?
Is the remote controller switch operated?Is there any faulty wiring?Are not terminal screws loosened?
M4......118 N·cm {12 kgf·cm}
M5......196 N·cm {20 kgf·cm}
M6......245 N·cm {25 kgf·cm}
M8......588 N·cm {60 kgf·cm}
- Measure the temperature of the intake and discharge air.
- Ensure the difference between the intake temperature and the discharge one is more than 8 °C (Cooling) or reversely (Heating).
TEST RUNNING
20
TEST RUNNING
ENGLISH
CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1 Never fail to have an individual power specialized for the air conditioner. As for the
method of wiring, be guided by the circuit diagram pasted on the inside of control box cover.
2 Provide a circuit breaker switch between power source and the unit. 3 The screw which fasten the wiring in the casing of electrical fittings are liable to come
loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of the wires.)
4 Specification of power source 5 Confirm that electrical capacity is sufficient. 6 Be sure that the starting voltage is maintained at more than 90 % of the rated voltage
marked on the name plate.
7 Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8 Never fail to equip a leakage breaker where it is wet or moist. 9 The following troubles would be caused by voltage drop-down.
- Vibration of a magnetic switch, damage on the contact point there of fuse breaking, dis­turbance to the normal function of a overload protection device.
- Proper starting power is not given to the compressor.
!
FUNCTION
21
ENGLISH
Forced cooling operation
Adding the refrigerant in winter.
• When the green LED of PCB is on, com­pressor is going to be off because of low pressure.
• You should return the dip switch to oper­ate normally after finishing the operation.
• Improper pump down will lead to product turn off along with LED (green &red) off with in 20 minutes from the initial start.
Pump down dip S/W setting
Power on
(Red LED on, Green LED off)
WARNING
!
Setting procedure
- Set the dip switch as follow after shutting the power source down.
- Reset the power.
- Red LED and Green LED of PCB lights during work. (The indoor unit is operated by force.)
- If operation is done, Red LED will be turned off. If operation is not done normally, Red LED will blink.
- Close the Liquid valve only after green LED turned off (7 minutes from the start of the machine). Then close the gas valve after Green LED on.
Liquid valve closed
Gas valve closed
Comp on
(Red LED on, Green LED on)
Pump down start
(Red LED on, Green LED off)
Pump down complete
(Red LED Off, Green LED On)
Power off
(Red LED Off, Green LED On)
FUNCTION
AVUQ36GM1A0
AVUQ48GM2A0 AVUQ60GM2A0
6 7 8 9 10
22
SELF-DIAGNOSIS FUNCTION
ENGLISH
Error indicator (outdoor)
Outdoor error Ex) Error 21 (DC Peak)
1 Time 1 Time 1 Time
2 Times2 Times2 Times
1 Sec.
2 Sec. 2 Sec.
1 Sec. 1 Sec.
LED 1 (RED)
LED 2
(GREEN)
SELF-DIAGNOSIS FUNCTION
AVUQ36GM1A0
AVUQ48GM2A0 AVUQ60GM2A0
SELF-DIAGNOSIS FUNCTION
23
ENGLISH
Error code Description
LED
(Red)
LED
(Red)
Indoor status
LED 1
(Red)
LED 2
(Green)
21 DC Peak (IPM Fault)
2times 1time
OFF
22 Max. CT (CT2)
2times 2times
OFF
23 DC Link low volt.
2times 3times
OFF
26 DC Comp position error
2times 6times
OFF
27 PFC Fault error
2times 7times
OFF
29 Comp over current
2times 9times
OFF
32 D-Pipe high (Inv.)
3times 2times
OFF
35 Low pressure error
3times 5times
OFF
41 Inv. D-Pipe sensor error (open/short)
4times 1time
OFF
43 Pressure sensor (open/short)
4times 3times
OFF
44 Outdoor air sensor error (open/short)
4times 4times
OFF
45 Cond. Middle pipe sensor error (open/short)
4times 5times
OFF
51 Capacity over
5times 1times
OFF
53
Communication error (indoor ÷ outdoor)
5times 3times
OFF
60 EEPROM error (outdoor)
6times
0 OFF
61 Cond. Middle pipe high
6times 1times
OFF
62 Heatsink error (high)
6times 2times
OFF
65 Heatsink sensor error (open/short)
6times 5times
OFF
67 BLDC motor fan lock (outdoor)
6times 7times
OFF
If abnormal voltage is supplied, the protection circuits will turn off the product in order to prevent the component damage. The product will automatically restart after 3 minutes.
INSTALLATION GUIDE AT THE SEASIDE
24
ENGLISH
If the outdoor unit is to be installed close to the seaside, direct exposure to the sea wind should be avoided. Install the outdoor unit on the opposite side of the sea wind direction.
In case, to install the outdoor unit on the seaside, set up a windbreak not to be exposed to the sea wind.
- It should be strong enough like concrete to prevent the sea wind from the sea.
- The height and width should be more than 150% of the outdoor unit.
- It should be keep more than 70 cm of space between outdoor unit and the windbreak for easy air flow.
Select a well-drained place.
Sea wind
Sea wind
Sea wind
Windbreak
• Periodic ( more than once/year ) clean­ing of the dust or salt particles stuck on the heat exchanger by using water
• Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced.
• Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient performance.
• If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind. Otherwise it needs additional anticorrosion treatment on the heat exchanger.
CAUTION
!
Selecting the location(Outdoor unit)
INSTALLATION GUIDE AT THE SEASIDE